Completely noninvasive multi-analyte monitoring system for cell culture processes

被引:1
|
作者
Rahmatnejad, Vida [1 ]
Tolosa, Michael [1 ]
Ge, Xudong [1 ]
Rao, Govind [1 ]
机构
[1] Univ Maryland Baltimore Cty, Ctr Adv Sensor Technol, Dept Chem Biochem & Environm Engn, Baltimore, MD 21250 USA
关键词
Dissolved carbon dioxide; Dissolved oxygen; Noninvasive; Sensor; Mammalian cell culture; Flow cell; DISSOLVED-OXYGEN; PH; DIFFUSION; CHIP; O-2;
D O I
10.1007/s10529-024-03521-z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Although online monitoring of dissolved O2, pH, and dissolved CO2 is critical in bioprocesses, nearly all existing technologies require some level of direct contact with the cell culture environment, posing risks of contamination. This study addresses the need for an accurate, and completely noninvasive technique for simultaneous measurement of these analytes. A "non-contact" technique for simultaneous monitoring of dissolved O2, pH, and dissolved CO2 was developed. Instead of direct contact with the culture media, the measurements were made through permeable membranes via either a sampling port in the culture vessel wall or a flow cell. The efficacy of the "non-contact" technique was validated in Escherichia coli (E.coli), Chinese hamster ovary (CHO) culture processes, and dynamic environments created by sparging gases in cell culture medium. The measurements obtained through the developed techniques were comparable to those obtained through control methods. The noninvasive monitoring system can offer accurate, and contamination-minimized monitoring of critical process parameters including dissolved O2, pH, and dissolved CO2. These advancements will enhance the control and optimization of cell culture processes, promising improved cell culture performance.
引用
收藏
页码:983 / 996
页数:14
相关论文
共 50 条
  • [41] SIGLE- AND MULTI-ANALYTE DETERMINATION USING A CHIP-BASED SURFACE ENHANCED RAMAN SCATTERING SYSTEM
    Ma Sai
    Liang Qionglin
    Wang Yiming
    Luo Guoan
    IFPT'6: PROGRESS ON POST-GENOME TECHNOLOGIES, PROCEEDINGS, 2009, : 151 - 153
  • [42] A multi-analyte cell-free DNA-based blood test for early detection of hepatocellular carcinoma
    Lin, Nan
    Lin, Yongping
    Xu, Jianfeng
    Liu, Dan
    Li, Diange
    Meng, Hongyu
    Gallant, Maxime A.
    Kubota, Naoto
    Roy, Dhruvajyoti
    Li, Jason S.
    Gorospe, Emmanuel C.
    Sherman, Morris
    Gish, Robert G.
    Abou-Alfa, Ghassan K.
    Nguyen, Mindie H.
    Taggart, David J.
    Van Etten, Richard A.
    Hoshida, Yujin
    Li, Wei
    HEPATOLOGY COMMUNICATIONS, 2022, 6 (07) : 1753 - 1763
  • [43] Development of AcroMetrix Multi-Analyte cfTNA (Cell-Free Total Nucleic Acid) Human Plasma Controls
    Gan, Q.
    Wagner, M.
    Siepert, N.
    Jayaweera, T.
    Hu, R.
    Liu, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2022, 24 (10): : S113 - S113
  • [44] REAL-TIME MULTI-ANALYTE ONLINE MONITORING OF 3D CELL CULTURES BY INTEGRATED ENZYME-BASED BIOSENSORS IN HANGING DROP NETWORKS
    Misun, P. M.
    Rothe, J.
    Hierlemann, A.
    Frey, O.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 1625 - 1628
  • [45] MULTI-ANALYTE DETECTION FOR BIOLOGICAL FLUIDS Towards Continous Monitoring of Glucose, Ionized Calcium and pH using a Viscometric Affinity Biosensor
    Boss, Christophe
    Meurville, Eric
    Ryser, Peter
    Schmitt, Frederic
    Juillerat-Jeanneret, Lucienne
    Dosil-Rosende, Pablo
    De Souza, Desdemona
    BIODEVICES 2011, 2011, : 295 - +
  • [46] Fluorophore-mediated, fiber-optic, multi-analyte, immunosensing system for rapid diagnosis and prognosis of cardiovascular diseases
    Tang, Liang
    Ren, Yongjie
    Hong, Bin
    Kang, Kyung A.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
  • [47] Cell-Bound Complement Activation Products in Multi-Analyte Assay with Algorithm Aid the Diagnosis of Systemic Lupus Erythematosus
    Mossell, James
    Goldman, John A.
    Barken, Derren
    Alexander, Roberta
    ARTHRITIS & RHEUMATOLOGY, 2016, 68
  • [48] Multi-analyte biosensor interface for real-time monitoring of 3D microtissue spheroids in hanging-drop networks
    Misun, Patrick M.
    Rothe, Jorg
    Schmid, Yannick R. F.
    Hierlemann, Andreas
    Frey, Olivier
    MICROSYSTEMS & NANOENGINEERING, 2016, 2
  • [49] Fast and simultaneous monitoring of organic pollutants in a drinking water treatment plant by a multi-analyte biosensor followed by LC-MS validation
    Rodriguez-Mozaz, S
    de Alda, MJL
    Barceló, D
    TALANTA, 2006, 69 (02) : 377 - 384
  • [50] Multi-analyte biosensor interface for real-time monitoring of 3D microtissue spheroids in hanging-drop networks
    Patrick M. Misun
    Jörg Rothe
    Yannick R.F. Schmid
    Andreas Hierlemann
    Olivier Frey
    Microsystems & Nanoengineering, 2