Clinical performance of a particle enhanced turbidimetric immunoassay (PETIA) for detecting fecal calprotectin

被引:0
|
作者
Wang, Tieshan [1 ]
Wang, Wei [1 ]
Zhu, Siying [2 ]
Zhou, Minsi [2 ]
Li, Peng [2 ]
Wu, Jing [2 ]
Zhang, Shutian [2 ]
Shi, Haiyun [2 ]
机构
[1] Capital Med Univ, Beijing Friendship Hosp, Clin Lab Ctr, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Friendship Hosp, Natl Clin Res Ctr Digest Dis, Dept Gastroenterol,Beijing Digest Dis Ctr, Beijing 100050, Peoples R China
关键词
fecal calprotectin; PETIA; ELISA; bowel diseases; clinical performance;
D O I
10.1080/00365513.2024.2403006
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Particle-enhanced turbidimetric immunoassay (PETIA) is a new measurement procedure for detecting fecal calprotectin (FC). We aimed to investigate the accuracy and clinical performance of PETIA for FC. We assessed the accuracy of PETIA for FC measurements through concordance analysis, Passing-Bablok regression and Bland-Altman analysis, using enzyme-linked immunosorbent assay (ELISA) as the reference. To evaluate the clinical performance of PETIA, the FC levels of individuals with significant and non-significant bowel diseases were compared. The receiver operating characteristic (ROC) analysis was performed to determine the appropriate cut-off value of FC detected by PETIA for discriminating subjects with significant and non-significant colorectal lesions. Of the 413 cases analyzed, 340 (82.3%) were concordant between PETIA and ELISA. No significant discordance was observed. There was a good agreement (y = -7.710+0.957x) between PETIA and ELISA for detecting FC. The FC level detected by PETIA in patients with significant bowel diseases (159.1 [31.3, 821.0] mu g/g) was significantly higher than that of subjects with non-significant bowel diseases (10.3 [4.2, 38.5] mu g/g) (p < 0.001). The AUC of FC for identifying significant bowel diseases detected by PETIA was 0.82 (p < 0.001). With a cut-off value of 77.6 mu g/g, the specificity and positive predictive value were 92.2% and 97.1%, respectively. The PETIA for FC measurement showed good clinical performance for detecting bowel diseases.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 50 条
  • [41] Undetectable phenytoin serum levels by an automated particle-enhanced turbidimetric inhibition immunoassay in a patient with monoclonal IgMλ
    Brauchli, Yolanda B.
    Scholer, Andre
    Schwietert, Martin
    Kraehenbuehl, Stephan
    CLINICA CHIMICA ACTA, 2008, 389 (1-2) : 174 - 176
  • [42] Evaluation of a particle-enhanced turbidimetric immunoassay for the measurement of ferritin:: Application to patients participating in an autologous blood transfusion program
    Gómez, F
    Simó, JM
    Camps, J
    Clivillé, X
    Bertran, N
    Ferré, N
    Bofill, C
    Joven, J
    CLINICAL BIOCHEMISTRY, 2000, 33 (03) : 191 - 196
  • [43] Clinical Value of Detecting Fecal Calprotectin by Using Colloidal Gold Assay in Screening or Diagnosing Crohn's Disease
    Zhang, Wangdong
    Fan, Yanyun
    Chen, Meijun
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2023, 2023
  • [44] Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Hitachi 917 analyzer
    Al-Turkmani, M. Rabie
    Law, Terence
    Kellogg, Mark D.
    CLINICA CHIMICA ACTA, 2008, 398 (1-2) : 75 - 77
  • [45] Clinical evaluation of a bioluminescent enzyme immunoassay for detecting norovirus in fecal specimens from patients with acute gastroenteritis
    Shigemoto, Naoki
    Tanizawa, Yukie
    Matsuo, Takeshi
    Sakamaki, Nozomi
    Ohiro, Yoshiyuki
    Takayasu, Susumu
    Fukuda, Shinji
    JOURNAL OF MEDICAL VIROLOGY, 2014, 86 (07) : 1219 - 1225
  • [46] A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
    Yanyan Xia
    Han Shen
    Yefei Zhu
    Hongpan Xu
    Zhiyang Li
    Jin Si
    Scientific Reports, 7
  • [47] A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
    Xia, Yanyan
    Shen, Han
    Zhu, Yefei
    Xu, Hongpan
    Li, Zhiyang
    Si, Jin
    SCIENTIFIC REPORTS, 2017, 7
  • [48] A comparison of diagnostic performance between two quantitative rapid fecal calprotectin assays in detecting active inflammatory bowel disease
    Lee, Jong-Mi
    Jang, Joo Hee
    Ryu, Ji Hyeong
    Yoo, Jaeeun
    Lee, Bo-In
    Kim, Seung-Jun
    Oh, Eun-Jee
    PLOS ONE, 2021, 16 (08):
  • [49] Analytical and clinical performance of the fully-automated LIAISONXL calprotectin immunoassay from DiaSorin in IBD patients
    Vicente-Steijn, R.
    Jansen, J. M.
    Bisheshar, R.
    Haagen, I. -A.
    PRACTICAL LABORATORY MEDICINE, 2020, 21
  • [50] Comparison of clinical performance of fecal calprotectin of laboratory methods with lateral flow based POC and home tests
    Reinhard, C.
    Penager, R.
    Ueberschlag, M. E.
    Krauchi, S.
    Trapani-Vondran, D.
    Kupchak, P.
    Schuster, T.
    JOURNAL OF CROHNS & COLITIS, 2024, 18 : I943 - I943