Clinical performance of a particle enhanced turbidimetric immunoassay (PETIA) for detecting fecal calprotectin

被引:0
|
作者
Wang, Tieshan [1 ]
Wang, Wei [1 ]
Zhu, Siying [2 ]
Zhou, Minsi [2 ]
Li, Peng [2 ]
Wu, Jing [2 ]
Zhang, Shutian [2 ]
Shi, Haiyun [2 ]
机构
[1] Capital Med Univ, Beijing Friendship Hosp, Clin Lab Ctr, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Friendship Hosp, Natl Clin Res Ctr Digest Dis, Dept Gastroenterol,Beijing Digest Dis Ctr, Beijing 100050, Peoples R China
关键词
fecal calprotectin; PETIA; ELISA; bowel diseases; clinical performance;
D O I
10.1080/00365513.2024.2403006
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Particle-enhanced turbidimetric immunoassay (PETIA) is a new measurement procedure for detecting fecal calprotectin (FC). We aimed to investigate the accuracy and clinical performance of PETIA for FC. We assessed the accuracy of PETIA for FC measurements through concordance analysis, Passing-Bablok regression and Bland-Altman analysis, using enzyme-linked immunosorbent assay (ELISA) as the reference. To evaluate the clinical performance of PETIA, the FC levels of individuals with significant and non-significant bowel diseases were compared. The receiver operating characteristic (ROC) analysis was performed to determine the appropriate cut-off value of FC detected by PETIA for discriminating subjects with significant and non-significant colorectal lesions. Of the 413 cases analyzed, 340 (82.3%) were concordant between PETIA and ELISA. No significant discordance was observed. There was a good agreement (y = -7.710+0.957x) between PETIA and ELISA for detecting FC. The FC level detected by PETIA in patients with significant bowel diseases (159.1 [31.3, 821.0] mu g/g) was significantly higher than that of subjects with non-significant bowel diseases (10.3 [4.2, 38.5] mu g/g) (p < 0.001). The AUC of FC for identifying significant bowel diseases detected by PETIA was 0.82 (p < 0.001). With a cut-off value of 77.6 mu g/g, the specificity and positive predictive value were 92.2% and 97.1%, respectively. The PETIA for FC measurement showed good clinical performance for detecting bowel diseases.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 50 条
  • [31] Evaluation of a particle-enhanced turbidimetric immunoassay for the measurement of immunoglobulin E in an ILab 900 analyzer
    Guaita, S
    Simó, JM
    Ferré, N
    Joven, J
    Camps, J
    CLINICAL CHEMISTRY, 1999, 45 (09) : 1557 - 1561
  • [32] Particle enhanced turbidimetric immunoassay for the determination of urine cystatin C on Cobas c501
    Sohrabian, Azita
    Noraddin, Feria Hikmet
    Flodin, Mats
    Fredricsson, Annika
    Larsson, Anders
    CLINICAL BIOCHEMISTRY, 2012, 45 (4-5) : 339 - 344
  • [33] A particle-enhanced turbidimetric immunoassay for quantitative determination of orosomucoid in urine: development, validation and reference values
    Christiansen, MS
    Blirup-Jensen, S
    Foged, L
    Larsen, M
    Magid, E
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (10) : 1168 - 1177
  • [35] Measurement of Urinary Cystatin C with a Particle-Enhanced Turbidimetric Immunoassay on Architect Ci8200
    Noraddin, Feria Hikmet
    Flodin, Mats
    Fredricsson, Annika
    Sohrabian, Azita
    Larsson, Anders
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2012, 26 (05) : 358 - 364
  • [36] Useful automated quantitative determination of serum cys-C by particle-enhanced turbidimetric immunoassay
    Sato, E
    Ito, T
    Tatsumi, N
    22ND WORLD CONGRESS OF PATHOLOGY & LABORATORY MEDICINE, 2003, : 179 - 182
  • [37] Measurement of cystatin C in human urine by particle-enhanced turbidimetric immunoassay on an automated biochemistry analyzer
    Makris, Konstantinos
    Nikolaki, Efthimia
    Nanopoulos, Konstantinos
    Pirgakis, Konstantinos M.
    Maltezos, Chrisostomos K.
    CLINICAL BIOCHEMISTRY, 2013, 46 (12) : 1128 - 1130
  • [38] Determination of serum lipoprotein lipase using a latex particle-enhanced turbidimetric immunoassay with an automated analyzer
    Machida, Tetsuo
    Miyashita, Kazuya
    Sone, Takuya
    Tanaka, Sayori
    Nakajima, Katsuyuki
    Saito, Masayuki
    Stanhope, Kimber
    Havel, Peter
    Sumino, Hiroyuki
    Murakami, Masami
    CLINICA CHIMICA ACTA, 2015, 442 : 130 - 135
  • [39] Undetectable Vancomycin Concentrations Utilizing a Particle Enhanced Turbidimetric Inhibition Immunoassay in a Patient with an Elevated IgM Level
    Cooper, April A.
    Cowart, Kevin
    Clayton, Amanda
    Paul, Josee
    CLINICAL LABORATORY, 2017, 63 (09) : 1527 - 1532
  • [40] CLINICAL PERFORMANCE OF HIGH THROUGHPUT, POINT OF CARE AND HOME FECAL CALPROTECTIN TESTS
    Reinhard, Christian
    Ueberschlag, Marie-Eve
    Krauchi, Sabine
    Trapani-Vondran, Daniela
    Penager, Romain
    Kupchak, Peter
    Shaw, Collin
    Schuster, Thomas
    GASTROENTEROLOGY, 2024, 166 (05) : S1100 - S1100