Computational Hemodynamic Evaluation of Different Surgical Designs of Systemic to Pulmonary Arterial Shunt Under Controlled Pulmonary Flow

被引:0
|
作者
Xiong, Jiwen [1 ,2 ,3 ,4 ]
Sun, Qi [2 ,3 ,4 ]
Liu, Jinfen [2 ,3 ,4 ]
Liu, Jinlong [1 ,2 ,3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Childrens Med Ctr, Sch Med, Inst Pediat Translat Med, Shanghai 200127, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Childrens Med Ctr, Sch Med, Dept Cardiothorac Surg, Shanghai 200127, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Engn Res Ctr Virtual Real Struct Heart D, Shanghai Childrens Med Ctr, Sch Med, Shanghai 200127, Peoples R China
[4] Shanghai Jiao Tong Univ, Shanghai Childrens Med Ctr, Sch Med, Shanghai Inst Pediat Congenital Heart Dis, Shanghai 200127, Peoples R China
来源
9TH EUROPEAN MEDICAL AND BIOLOGICAL ENGINEERING CONFERENCE, VOL 1, EMBEC 2024 | 2024年 / 112卷
关键词
Systemic to Pulmonary Arterial Shunt; Virtual Surgery; Computational Fluid Dynamics; Hemodynamics; BLALOCK-TAUSSIG SHUNT; WALL SHEAR-STRESS; PALLIATION; AORTA;
D O I
10.1007/978-3-031-61625-9_26
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Systemic to pulmonary arterial shunt including modified central shunt (MCS) and modified Blalock-Taussig shunt (MBTS) are widely applied surgeries to increase pulmonary perfusion. It's crucial to ensure the pulmonary flow was well-controlled within a reasonable range, since both excessive and insufficient pulmonary perfusion leads to poor prognosis. The pulmonary flow could be well-controlled by selecting various shunt designs, e.g. shunt location and size. However, the hemodynamic performance of different designs is less explored under equivalent and reasonable pulmonary flow. Here, the individualized vascular model was reconstructed. To realize appropriate and equivalent pulmonary flow, three virtual surgeries including 4 mm left MBTS, 4 mm MCS, and 5 mm right MBTS were implemented using computer-aided design (CAD). The postoperative hemodynamic parameters were calculated by computational fluid dynamics (CFD). The results showed the postoperative models had equivalent pulmonary flow. The left MBTS had a better performance in balancing the pulmonary flow distribution. The right MBTS had a lower wall shear stress (WSS) and time-averaged WSS region in the shunt. The flow vortex and shear stress fluctuations were hardly avoidable in pulmonary arteries. In conclusion, the appropriate and equivalent pulmonary flow could be well realized by a larger-sized shunt when changing the shunt location of MBTS to the third aortic branch, compared with the MCS. The pulmonary flow distribution is greatly affected by the shunt location and vascular anatomy. The assessment and monitoring of thrombosis risk is requisite during perioperative management and postoperative follow-up no matter what shunt design is applied.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 50 条
  • [21] USE OF DOUBLY TAPERED GRAFT FOR CREATION OF A SYSTEMIC-PULMONARY ARTERIAL SHUNT
    BRAUNWALD, NS
    CASTANEDA, AR
    ANNALS OF THORACIC SURGERY, 1976, 22 (03): : 239 - 244
  • [22] A NEW TECHNIQUE FOR USE OF AN ANOMALOUS SUBCLAVIAN ARTERY FOR A SYSTEMIC PULMONARY ARTERIAL SHUNT
    VANSON, JAM
    VINCENT, JG
    VANOORT, A
    LACQUET, LK
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 99 (02): : 371 - 372
  • [23] INTRALUMINAL SHUNT TECHNIQUE IN SYSTEMIC TO PULMONARY ARTERIAL ANASTOMOSIS FOR SEVERELY CYANOTIC PATIENTS
    SHIMIZU, T
    IYOMASA, Y
    ABE, T
    MURASE, M
    TANAKA, M
    JOURNAL OF CARDIOVASCULAR SURGERY, 1982, 23 (02): : 172 - 174
  • [24] HEMODYNAMIC-EFFECTS OF BIDIRECTIONAL CAVOPULMONARY SHUNT (BCPS) WITH PULSATILE PULMONARY FLOW
    KOBAYASHI, J
    SHIMAZAKI, Y
    MITSUNO, M
    IKAWA, S
    KASAI, Y
    CIRCULATION, 1990, 82 (04) : 415 - 415
  • [25] Evidence for ANTXR2 as a therapeutic target on systemic-to-pulmonary shunt induced pulmonary arterial hypertension
    Liu, X. Y.
    Meng, L. K.
    Yuan, W.
    Zheng, M. L.
    Chi, H. J.
    Yang, X. C.
    Li, J.
    Zhong, J. C.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3693 - 3693
  • [26] Physical and computer modelling of blood flow in a systemic-to-pulmonary shunt
    Malota, Z
    Nawrat, Z
    Kostka, P
    Mizerski, J
    Nowinski, K
    Waniewski, J
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2004, 27 (11): : 990 - 999
  • [27] HEMODYNAMIC COMPLICATIONS IN SYSTEMIC SCLEROSIS PATIENTS WITH VARIOUS STAGES OF PULMONARY ARTERIAL HYPERTENSION
    Inaba, T.
    Hatano, M.
    Yao, A.
    Maki, H.
    Imamura, T.
    Shiga, T.
    Kinugawa, K.
    Nagai, R.
    Asano, Y.
    Sumida, H.
    Takahashi, T.
    Toyama, T.
    Ichimura, Y.
    Taniguchi, T.
    Sato, S.
    ANNALS OF THE RHEUMATIC DISEASES, 2013, 71 : 404 - 404
  • [28] Hemodynamic Complications in Systemic Sclerosis Patients with Various Stages of Pulmonary Arterial Hypertension
    Inaba, Toshiro
    Hatano, Masaru
    Yao, Atsushi
    Maki, Hisataka
    Imamura, Teruhiko
    Kato, Naoko
    Muraoka, Hironori
    Minatsuki, Shun
    Shiga, Taro
    Kinugawa, Koichiro
    CIRCULATION, 2012, 126 (21)
  • [29] Pulmonary arterial hemodynamic assessment by a novel index in systemic lupus erythematosus patients: pulmonary pulse transit time
    Efe, Tolga Han
    Dogan, Mehmet
    Ozisler, Cem
    Cimen, Tolga
    Felekoglu, Mehmet Ali
    Ertem, Ahmet Goktug
    Algul, Engin
    Acikel, Sadik
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2017, 18 (03): : 223 - 228
  • [30] Two-Day Control of Pulmonary Blood Flow with an Adjustable Systemic-Pulmonary Artery Shunt
    Mohiuddin, Mohammad W.
    Resig, Philip P.
    Sexton, Kevin W.
    Douglas, William I.
    ASAIO JOURNAL, 2011, 57 (03) : 225 - 230