Computational Hemodynamic Evaluation of Different Surgical Designs of Systemic to Pulmonary Arterial Shunt Under Controlled Pulmonary Flow

被引:0
|
作者
Xiong, Jiwen [1 ,2 ,3 ,4 ]
Sun, Qi [2 ,3 ,4 ]
Liu, Jinfen [2 ,3 ,4 ]
Liu, Jinlong [1 ,2 ,3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Childrens Med Ctr, Sch Med, Inst Pediat Translat Med, Shanghai 200127, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Childrens Med Ctr, Sch Med, Dept Cardiothorac Surg, Shanghai 200127, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Engn Res Ctr Virtual Real Struct Heart D, Shanghai Childrens Med Ctr, Sch Med, Shanghai 200127, Peoples R China
[4] Shanghai Jiao Tong Univ, Shanghai Childrens Med Ctr, Sch Med, Shanghai Inst Pediat Congenital Heart Dis, Shanghai 200127, Peoples R China
来源
9TH EUROPEAN MEDICAL AND BIOLOGICAL ENGINEERING CONFERENCE, VOL 1, EMBEC 2024 | 2024年 / 112卷
关键词
Systemic to Pulmonary Arterial Shunt; Virtual Surgery; Computational Fluid Dynamics; Hemodynamics; BLALOCK-TAUSSIG SHUNT; WALL SHEAR-STRESS; PALLIATION; AORTA;
D O I
10.1007/978-3-031-61625-9_26
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Systemic to pulmonary arterial shunt including modified central shunt (MCS) and modified Blalock-Taussig shunt (MBTS) are widely applied surgeries to increase pulmonary perfusion. It's crucial to ensure the pulmonary flow was well-controlled within a reasonable range, since both excessive and insufficient pulmonary perfusion leads to poor prognosis. The pulmonary flow could be well-controlled by selecting various shunt designs, e.g. shunt location and size. However, the hemodynamic performance of different designs is less explored under equivalent and reasonable pulmonary flow. Here, the individualized vascular model was reconstructed. To realize appropriate and equivalent pulmonary flow, three virtual surgeries including 4 mm left MBTS, 4 mm MCS, and 5 mm right MBTS were implemented using computer-aided design (CAD). The postoperative hemodynamic parameters were calculated by computational fluid dynamics (CFD). The results showed the postoperative models had equivalent pulmonary flow. The left MBTS had a better performance in balancing the pulmonary flow distribution. The right MBTS had a lower wall shear stress (WSS) and time-averaged WSS region in the shunt. The flow vortex and shear stress fluctuations were hardly avoidable in pulmonary arteries. In conclusion, the appropriate and equivalent pulmonary flow could be well realized by a larger-sized shunt when changing the shunt location of MBTS to the third aortic branch, compared with the MCS. The pulmonary flow distribution is greatly affected by the shunt location and vascular anatomy. The assessment and monitoring of thrombosis risk is requisite during perioperative management and postoperative follow-up no matter what shunt design is applied.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 50 条
  • [11] Novel technique of achieving hemodynamic stability during systemic to pulmonary artery shunt
    Seetharama Padebettu Subramanya Bhat
    Chirag Sumithra Prasannakumar
    Indian Journal of Thoracic and Cardiovascular Surgery, 2021, 37 : 722 - 725
  • [12] Novel technique of achieving hemodynamic stability during systemic to pulmonary artery shunt
    Bhat, Seetharama Padebettu Subramanya
    Prasannakumar, Chirag Sumithra
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 37 (06) : 722 - 725
  • [13] PULSATILE CAVO-PULMONARY ARTERY SHUNT - SURGICAL TECHNIQUE AND HEMODYNAMIC CHARACTERISTICS
    FURUSE, A
    BRAWLEY, RK
    GOTT, VL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1972, 63 (03): : 495 - +
  • [14] DAN plays important compensatory roles in systemic-to-pulmonary shunt associated pulmonary arterial hypertension
    Meng, Liukun
    Liu, Xiaoyan
    Teng, Xiao
    Yuan, Wen
    Duan, Lihua
    Meng, Jian
    Li, Jun
    Zheng, Zhe
    Wei, Yingjie
    Hu, Shengshou
    ACTA PHYSIOLOGICA, 2019, 226 (03)
  • [15] Haemodynamic and clinical variables after surgical systemic to pulmonary artery shunt placement versus arterial ductal stenting
    Sheth, Saloni P.
    Loomba, Rohit S.
    CARDIOLOGY IN THE YOUNG, 2023, 33 (10) : 2060 - 2065
  • [16] PULMONARY ARTERIAL-PRESSURE AS A GUIDE TO HEMODYNAMIC STATUS OF SURGICAL PATIENTS
    SHAREFKIN, JB
    MACARTHUR, JD
    ARCHIVES OF SURGERY, 1972, 105 (05) : 699 - +
  • [17] Pulmonary Arterial Hemodynamic Assessment by a Novel Index in Systemic Sclerosis Patients: Pulmonary Pulse Transit Time
    Mehmet Dogan
    Tolga Han Efe
    Tolga Cimen
    Cem Ozisler
    Mehmet Ali Felekoglu
    Ahmet Goktug Ertem
    Mehmet Erat
    Omer Yiginer
    Murat Tulmac
    Lung, 2018, 196 : 173 - 178
  • [18] Pulmonary Arterial Hemodynamic Assessment by a Novel Index in Systemic Sclerosis Patients: Pulmonary Pulse Transit Time
    Dogan, Mehmet
    Efe, Tolga Han
    Cimen, Tolga
    Ozisler, Cem
    Felekoglu, Mehmet Ali
    Ertem, Ahmet Goktug
    Erat, Mehmet
    Yiginer, Omer
    Tulmac, Murat
    LUNG, 2018, 196 (02) : 173 - 178
  • [19] PULMONARY ARTERIAL BANDING HEMODYNAMIC AND CLINICAL EVALUATION IN 23 CASES
    MERINOBATRES, G
    RICOGOMEZ, F
    GONZALEZDIEGUEZ, C
    MARINHUERTA, E
    QUEROJIMENEZ, M
    ANALES ESPANOLES DE PEDIATRIA, 1977, 10 (11): : 809 - 814
  • [20] A NEW TECHNIQUE FOR USE OF AN ANOMALOUS SUBCLAVIAN ARTERY FOR A SYSTEMIC PULMONARY ARTERIAL SHUNT
    YAMAGUCHI, M
    OBO, H
    OSHIMA, Y
    OHASHI, H
    HOSOKAWA, Y
    TACHIBANA, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1989, 97 (01): : 110 - 113