Method Development and Validation for the Quantification of Abametapir in Biological Matrices by LC-ESI-MS/MS

被引:0
|
作者
Krishnan, Vinayaga Sundaram
Bhikshapathi, Darna [1 ,2 ,3 ]
Cheruku, Shankar [2 ]
机构
[1] Bir Tikandrajit Univ, Dept Chem, Imphal, Manipur, India
[2] Bir Tikandrajit Univ, Dept Pharm, Imphal, Manipur, India
[3] TRR Coll Pharm, Dept Pharmaceut Anal, Hyderabad, Telangana, India
关键词
LC-MS/MS; Abametapir; Metalloproteinase Inhibitor; Validation; Accuracy; Linearity; HUMAN PLASMA; LICE;
D O I
10.5530/ijper.58.3s.102
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Aim: A precise, linear and specific liquid chromatography-tandem mass spectrometry procedure was executed and subjected for validation for the quantification of plasma. Materials and Methods: The chromatography elution was carried out using a C18-Discovery column of 15 cm in length and 2.1 mm in internal diameter, packed with stationary phase particles of 5 mu m size, at a flow rate of 0.80 mL/min. An isocratic elution process was conducted with a mobile phase solution consisting of methanol and 0.10% V/V HCOOH in a ratio of 90:10. The separation of Abametapir and Metformin was achieved by a liquid-liquid extraction process using ethyl acetate as the solvent. Results: A triple quadrupole mass spectrometer was used for the measurement of ions. Electrospray ionization is a technology that ionizes positively, and it was used in Multiple Reaction Monitoring (MRM) with parent/product ionic transitions m/z 185.1-106.06 for Abametapir and 130.1-60.20 for the Metformin internal standard. A calibration graph was constructed with values ranging from 2.05 to 82.00 ng/mL, resulting in the equation y=0.0149x+0.00221, with a r2 value above 0.99. The recovery values of Abametapir exceeded 94.27%, with its accuracy assessed in terms of relative error ranging from -4.04% to 6.52%. Conclusion: The accuracy, recovery and sensitivity values of Abametapir in the plasma sample, as shown by the established approach, highlight its significance in pharmacokinetic and bioequivalence research.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Quantification of desloratadine in human plasma by LC-ESI-MS/MS and application to a pharmacokinetic study
    Venkata Suresh Ponnuru
    B.R. Challa
    Ramarao Nadendla
    JournalofPharmaceuticalAnalysis, 2012, 2 (03) : 180 - 187
  • [42] Simultaneous quantification of free curcuminoids and their metabolites in equine plasma by LC-ESI-MS/MS
    Liu, Yongqiang
    Siard, Melissa
    Adams, Amanda
    Keowen, Michael L.
    Miller, Travis K.
    Garza, Frank, Jr.
    Andrews, Frank M.
    Seeram, Navindra P.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 154 : 31 - 39
  • [43] Development and validation of an LC-MS/MS/MS method for the quantification of fluoroquinolones in several matrices from treated turkeys
    Lucatello, Lorena
    Cagnardi, Petra
    Capolongo, Francesca
    Ferraresi, Caterina
    Bernardi, Filippo
    Montesissa, Clara
    FOOD CONTROL, 2015, 48 : 2 - 11
  • [44] Development and validation of a multiresidue method for the determination of 323 pesticide residues in dry herbs using QuEChERS method and LC-ESI-MS/MS
    Abbas, Mohamed S.
    Soliman, Amira Sh.
    El-Gammal, Hassan A.
    Amer, Mohamed E.
    Attallah, Emad R.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (11) : 1003 - 1023
  • [45] METHOD DEVELOPMENT AND VALIDATION OF LC-ESI-MS/MS TECHNIQUE FOR THE ESTIMATION OF MODAFINIL IN HUMAN PLASMA; APPLICATION TO PHARMACOKINETICS IN HEALTHY RABBITS
    Phanindra, Adluri
    Kumar, Y. Shravan
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (04): : 1837 - 1844
  • [46] Development and validation of a LC-ESI-MS/MS method for the determination of phenolic compounds in honeydew honeys with the diluted-and-shoot approach
    Tischer Seraglio, Siluana Katia
    Valese, Andressa Camargo
    Daguer, Heitor
    Bergamo, Greici
    Azevedo, Monia Stremel
    Gonzaga, Luciano Valdemiro
    Fett, Roseane
    Oliveira Costa, Ana Carolina
    FOOD RESEARCH INTERNATIONAL, 2016, 87 : 60 - 67
  • [47] Development and validation of an LC-ESI-MS/MS method for simultaneous quantitation of olmesartan and pioglitazone in rat plasma and its pharmacokinetic application
    Sengupta, Pinaki
    Sarkar, Amlan Kanti
    Bhaumik, Uttam
    Chatterjee, Bappaditya
    Roy, Bikash
    Chakraborty, Uday Shankar
    Pal, Tapan Kumar
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (12) : 1342 - 1349
  • [48] Development of a LC-ESI-MS/MS Approach for the Rapid Quantification of Main Wine Organic Acids in Human Urine
    Regueiro, Jorge
    Vallverdu-Queralt, Anna
    Simal-Gandara, Jesus
    Estruch, Ramon
    Lamuela-Raventos, Rosa
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (27) : 6763 - 6768
  • [49] Analysis and validation of perfluorinated compounds in water, sediment and fish with LC-ESI-MS/MS
    Kaupmees, Siiri
    Rebane, Riin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (08) : 695 - 709
  • [50] Development of Fast and Simple LC-ESI-MS/MS Technique for the Quantification of Regorafenib; Application to Pharmacokinetics in Healthy Rabbits
    Ravi, Yatha
    Bhikshapathi, D. V. R. N.
    Cheruku, Shankar
    Rajkamal, Bigala
    CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (04) : 554 - 563