Method Development and Validation for the Quantification of Abametapir in Biological Matrices by LC-ESI-MS/MS

被引:0
|
作者
Krishnan, Vinayaga Sundaram
Bhikshapathi, Darna [1 ,2 ,3 ]
Cheruku, Shankar [2 ]
机构
[1] Bir Tikandrajit Univ, Dept Chem, Imphal, Manipur, India
[2] Bir Tikandrajit Univ, Dept Pharm, Imphal, Manipur, India
[3] TRR Coll Pharm, Dept Pharmaceut Anal, Hyderabad, Telangana, India
关键词
LC-MS/MS; Abametapir; Metalloproteinase Inhibitor; Validation; Accuracy; Linearity; HUMAN PLASMA; LICE;
D O I
10.5530/ijper.58.3s.102
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Aim: A precise, linear and specific liquid chromatography-tandem mass spectrometry procedure was executed and subjected for validation for the quantification of plasma. Materials and Methods: The chromatography elution was carried out using a C18-Discovery column of 15 cm in length and 2.1 mm in internal diameter, packed with stationary phase particles of 5 mu m size, at a flow rate of 0.80 mL/min. An isocratic elution process was conducted with a mobile phase solution consisting of methanol and 0.10% V/V HCOOH in a ratio of 90:10. The separation of Abametapir and Metformin was achieved by a liquid-liquid extraction process using ethyl acetate as the solvent. Results: A triple quadrupole mass spectrometer was used for the measurement of ions. Electrospray ionization is a technology that ionizes positively, and it was used in Multiple Reaction Monitoring (MRM) with parent/product ionic transitions m/z 185.1-106.06 for Abametapir and 130.1-60.20 for the Metformin internal standard. A calibration graph was constructed with values ranging from 2.05 to 82.00 ng/mL, resulting in the equation y=0.0149x+0.00221, with a r2 value above 0.99. The recovery values of Abametapir exceeded 94.27%, with its accuracy assessed in terms of relative error ranging from -4.04% to 6.52%. Conclusion: The accuracy, recovery and sensitivity values of Abametapir in the plasma sample, as shown by the established approach, highlight its significance in pharmacokinetic and bioequivalence research.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Development and validation of an LC-MS/MS assay for the quantification of efavirenz in different biological matrices
    Curley, Paul
    Siccardi, Marco
    Moss, Darren M.
    Owen, Andrew
    BIOANALYSIS, 2016, 8 (20) : 2125 - 2134
  • [22] Development and validation of LC-ESI-MS/MS methods for quantification of 27 free and conjugated estrogen-related metabolites
    van der Berg, Carien
    Venter, Gerda
    van der Westhuizen, Francois H.
    Erasmus, Elardus
    ANALYTICAL BIOCHEMISTRY, 2020, 590
  • [23] Determination of five macrolide antibiotic residues in honey by LC-ESI-MS and LC-ESI-MS/MS
    Wang, J
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (02) : 171 - 181
  • [24] LC-ESI-MS/MS method for the enantioseparation of six flavanones
    Baranowska, Irena
    Hejniak, Judyta
    Magiera, Sylwia
    ANALYTICAL METHODS, 2017, 9 (06) : 1018 - 1030
  • [25] LC-ESI-MS/MS method for quantification of ambrisentan in plasma and application to rat pharmacokinetic study
    Nirogi, Ramakrishna
    Kandikere, Vishwottam
    Komarneni, Prashanth
    Aleti, Raghupathi
    Padala, NagaSuryaPrakash
    Kalaikadhiban, Ilayaraja
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (10) : 1150 - 1156
  • [26] Method Development and Validation for Determination of Indoxacarb Using LC-ESI-MS/MS and Its Dissipation Kinetics in Pigeonpea
    Harischandra R Naik
    M. S Pallavi
    Rahul Chawan
    M Bheemanna
    Anand Naik
    M Paramasivam
    Food Analytical Methods, 2020, 13 : 647 - 657
  • [27] Development and validation of a LC-ESI-MS/MS method for the determination of swertiamarin in rat plasma and its application in pharmacokinetics
    Li, Hong-Liang
    Peng, Xiao-Jin
    He, Jian-Chang
    Feng, En-Fu
    Xu, Gui-Li
    Rao, Gao-Xiong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (19): : 1653 - 1658
  • [28] A sensitive LC-ESI-MS/MS method for the quantification of low concentrations of buspirone in human plasma
    Joshi, Pankaj
    Rao, Shireen
    Singh, Manoj
    Vig, Nitin
    Singh, Abhay Kant
    Rajawat, Narendra Singh
    Gupta, Ankush
    ANALYTICAL METHODS, 2013, 5 (24) : 7014 - 7021
  • [29] Method Development and Validation for Determination of Indoxacarb Using LC-ESI-MS/MS and Its Dissipation Kinetics in Pigeonpea
    Naik, Harischandra R.
    Pallavi, M. S.
    Chawan, Rahul
    Bheemanna, M.
    Naik, Anand
    Paramasivam, M.
    FOOD ANALYTICAL METHODS, 2020, 13 (03) : 647 - 657
  • [30] Development and validation of a rapid and sensitive LC-ESI-MS/MS method for ondansetron quantification in human plasma and its application in comparative bioavailability study
    Moreira, Roberto F.
    Salvadori, Myriam C.
    Azevedo, Cristina P.
    Oliveira-Silva, Diogo
    Borges, Diego C.
    Moreno, Ronlison A.
    Sverdloff, Carlos E.
    Borges, Ney C.
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (11) : 1220 - 1227