Photon-Counting Detector CT for Liver Lesion Detection-Optimal Virtual Monoenergetic Energy for Different Simulated Patient Sizes and Radiation Doses

被引:4
|
作者
Racine, Damien [1 ]
Mergen, Victor [2 ]
Viry, Anais [1 ]
Frauenfelder, Thomas [2 ]
Alkadhi, Hatem [2 ]
Vitzthum, Veronika [1 ]
Euler, Andre [2 ,3 ]
机构
[1] Univ Lausanne, Univ Hosp Lausanne CHUV, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[3] Kantonsspital Baden, Dept Radiol, Ergel 1, CH-5404 Baden, Switzerland
关键词
liver; phantom; photon-counting CT; lesion detectability; radiation dose; image reconstruction; VMI optimization; CHANNELIZED HOTELLING OBSERVER; LOW-CONTRAST DETECTABILITY; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; NOISE; TASK; PERFORMANCE; SELECTION; MODEL; MDCT;
D O I
10.1097/RLI.0000000000001060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the optimal energy level of virtual monoenergetic images (VMIs) from photon-counting detector computed tomography (CT) for the detection of liver lesions as a function of phantom size and radiation dose.Materials and MethodsAn anthropomorphic abdominal phantom with liver parenchyma and lesions was imaged on a dual-source photon-counting detector CT at 120 kVp. Five hypoattenuating lesions with a lesion-to-background contrast difference of -30 HU and -45 HU and 3 hyperattenuating lesions with +30 HU and +90 HU were used. The lesion diameter was 5-10 mm. Rings of fat-equivalent material were added to emulate medium- or large-sized patients. The medium size was imaged at a volume CT dose index of 5, 2.5, and 1.25 mGy and the large size at 5 and 2.5 mGy, respectively. Each setup was imaged 10 times. For each setup, VMIs from 40 to 80 keV at 5 keV increments were reconstructed with quantum iterative reconstruction at a strength level of 4 (QIR-4). Lesion detectability was measured as area under the receiver operating curve (AUC) using a channelized Hotelling model observer with 10 dense differences of Gaussian channels.ResultsOverall, highest detectability was found at 65 and 70 keV for both hypoattenuating and hyperattenuating lesions in the medium and large phantom independent of radiation dose (AUC range, 0.91-1.0 for the medium and 0.94-0.99 for the large phantom, respectively). The lowest detectability was found at 40 keV irrespective of the radiation dose and phantom size (AUC range, 0.78-0.99). A more pronounced reduction in detectability was apparent at 40-50 keV as compared with 65-75 keV when radiation dose was decreased. At equal radiation dose, detection as a function of VMI energy differed stronger for the large size as compared with the medium-sized phantom (12% vs 6%).ConclusionsDetectability of hypoattenuating and hyperattenuating liver lesions differed between VMI energies for different phantom sizes and radiation doses. Virtual monoenergetic images at 65 and 70 keV yielded highest detectability independent of phantom size and radiation dose.
引用
收藏
页码:554 / 560
页数:7
相关论文
共 50 条
  • [31] Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT
    Rajendran, Kishore
    Bruesewitz, Michael
    Swicklik, Joseph
    Ferrero, Andrea
    Thorne, Jamison
    Yu, Lifeng
    McCollough, Cynthia
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11):
  • [32] Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization-A Head to Head Comparison to Energy-Integrating Detector CT
    Waldeck, Stephan
    Overhoff, Daniel
    Alizadeh, Leona
    Becker, Benjamin, V
    Port, Matthias
    Froelich, Matthias F.
    Brockmann, Marc A.
    Schumann, Sven
    Vogl, Thomas J.
    Schoenberg, Stefan O.
    Schmidt, Sandra
    TOMOGRAPHY, 2022, 8 (04) : 1642 - 1648
  • [33] Detection of myeloma-associated osteolytic bone lesions with energy-integrating and photon-counting detector CT
    Groezinger, Martin
    Wennmann, Markus
    Sawall, Stefan
    Wehrse, Eckhard
    Sedaghat, Sam
    Neelsen, Christian
    Bauer, Fabian
    Goldschmidt, Hartmut
    Weru, Vivienn
    Ziener, Christian H.
    Kopp-Schneider, Annette
    Schlemmer, Heinz-Peter
    Rotkopf, Lukas T.
    RADIOLOGIE, 2024, 64 (SUPPL 1): : 24 - 31
  • [34] Improved display and detection of small renal stones using photon-counting detector CT compared to conventional energy-integrating detector CT
    Esquivel, Andrea
    Potretzke, Theodora
    Ferrero, Andrea
    Inoue, Akitoshi
    Hoodeshenans, Safa
    Mileto, Achille
    Winfree, Timothy
    Yalon, Mariana
    Khandelwal, Ashish
    Rajendran, Kishore
    Thorne, Jamison E.
    Lee, Yong S.
    Potretzke, Aaron
    Leng, Shuai
    Mccollough, Cynthia H.
    Fletcher, Joel G.
    ABDOMINAL RADIOLOGY, 2025,
  • [35] Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT
    El-Ali, Alexander M.
    Strubel, Naomi
    Pinkney, Lynne
    Xue, Christine
    Dane, Bari
    Lala, Shailee V.
    PEDIATRIC RADIOLOGY, 2024, 54 (12) : 1984 - 1995
  • [36] Editorial Comment: Stability of Virtual Monoenergetic Images From Photon-Counting Detector CT May Allow Broader Quantitative Applications in Research and Clinical Practice
    Obmann, Markus M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (05)
  • [37] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [38] Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT
    Josua A. Decker
    Judith Becker
    Mark Härting
    Bertram Jehs
    Franka Risch
    Luca Canalini
    Claudia Wollny
    Christian Scheurig-Muenkler
    Thomas Kroencke
    Florian Schwarz
    Stefanie Bette
    Abdominal Radiology, 2024, 49 : 103 - 116
  • [39] Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT
    Decker, Josua A.
    Becker, Judith
    Haerting, Mark
    Jehs, Bertram
    Risch, Franka
    Canalini, Luca
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas
    Schwarz, Florian
    Bette, Stefanie
    ABDOMINAL RADIOLOGY, 2024, 49 (01) : 103 - 116
  • [40] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 13