Pediatric contrast-enhanced chest CT on a photon-counting detector CT: radiation dose and image quality compared to energy-integrated detector CT

被引:1
|
作者
El-Ali, Alexander M. [1 ,2 ]
Strubel, Naomi [1 ,2 ]
Pinkney, Lynne [1 ,2 ]
Xue, Christine [1 ,2 ]
Dane, Bari [1 ,3 ]
Lala, Shailee V. [1 ,2 ]
机构
[1] New York Univ Langone Med Ctr, New York, NY 10016 USA
[2] NYU Grossman Sch Med, Div Pediat Radiol, Dept Radiol, 660 First Ave, New York, NY 10016 USA
[3] NYU Grossman Sch Med, Div Body Imaging, Dept Radiol, 660 First Ave, New York, NY 10016 USA
关键词
Child; Contrast media; Lung; Photons; Radiation dosage; Tomography; X-ray computed; COMPUTED-TOMOGRAPHY; AGREEMENT;
D O I
10.1007/s00247-024-06078-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Photon counting detector (PCD) CT benefits from reduced noise compared with conventional energy-integrating detector (EID) CT, which should translate to improved image quality and reduced radiation exposure for pediatric patients undergoing chest CT with IV contrast. Objective To determine the differences in radiation exposure and image quality of PCD CT and EID CT in pediatric chest CT with intravenous (IV) contrast. Materials and methods In this institutional review board-approved retrospective observational study, 20 scan pairs (20 PCD CT; 20 EID CT) for children who underwent chest CT with IV contrast on both a PCD CT (Siemens NAEOTOM Alpha) and an EID CT (Siemens SOMATOM Definition Edge or Force) within 12 months were reviewed independently by three pediatric radiologists for three subjective quality features on 5-point Likert scales: overall quality, small structure delineation, and motion artifact. Objective measures of image quality (image noise, signal-to-noise ratio, and contrast-to-noise ratio) were assessed by a single radiologist in several locations in the chest through region of interest measurement of Hounsfield units (HU) and standard deviation. Patient-related and radiation exposure parameters were collected for each scan and summarized with median and interquartile range (IQR). The Wilcoxon rank-sum test was utilized to compare groups. A P < 0.05 indicated statistical significance. Inter-observer agreement of subjective image quality metrics was analyzed using weighted kappa. Results Age (14.2 years vs 13.8 years, P= 0.15), height (P= 0.13), weight (P= 0.21), and BMI (P = 0.24) did not significantly differ between groups. There were 10 male and 3 female patients. Compared to EID CT, PCD CT showed lower radiation exposure parameters including volumetric CT dose index, 1.7 mGy (IQR 1.1-2.4 mGy) vs 3.8 mGy (IQR 2.0-4.7 mGy) (P< 0.01), and size-specific dose estimate, 2.6 mGy (IQR 1.8-3.1 mGy) vs 5.0 mGy (IQR 3.3-6.2 mGy) (P< 0.01). Objective image quality of lung parenchyma was improved on the PCD CT scanner, including image noise 119.5 HU (IQR 95.4-135.7 HU) vs 143.1 HU (IQR 125.4-169.8 HU) (P < 0.01), signal-to-noise ratio (SNR) -6.1 (IQR -8.4 to -4.8) vs -4.9 (IQR -5.6 to -3.8) (P= 0.01), and contrast-to-noise ratio -63.9 (-84.1 to -57.5) vs -60.5 (-76.3 to -52.5) (P = 0.01). Motion artifact was improved on the PCD CT scanner (P< 0.01). No significant differences in overall image quality or small structure delineation were identified (P= 0.06 and P= 0.31). Conclusion PCD CT pediatric chest CT had significantly reduced radiation exposure, improved image quality, and reduced motion artifact compared with EID CT.
引用
收藏
页码:1984 / 1995
页数:12
相关论文
共 50 条
  • [1] Comparison of Radiation Dose and Image Quality of Pediatric High-Resolution Chest CT Between Photon-Counting Detector CT and Energy-Integrated Detector CT: A Matched Study
    Siegel, Marilyn J.
    Bugenhagen, Scott M.
    Sanchez, Adrian
    Kim, Stacy
    Abadia, Andres
    Ramirez-Giraldo, Juan C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 221 (03) : 363 - 371
  • [2] Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT
    Higashigaito, Kai
    Euler, Andre
    Eberhard, Matthias
    Flohr, Thomas G.
    Schmidt, Bernhard
    Alkadhi, Hatem
    ACADEMIC RADIOLOGY, 2022, 29 (05) : 689 - 697
  • [3] Comparison of Image Quality and Radiation Dose in Pediatric Temporal Bone CT Using Photon-Counting Detector CT and Energy-Integrating Detector CT
    Lee, Jeong Sub
    Kim, John
    Bapuraj, Jayapalli R.
    Srinivasan, Ashok
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (09) : 1322 - 1326
  • [4] Photon-counting detector CT allows significant reduction in radiation dose while maintaining image quality and noise on non-contrast chest CT
    Donuru, Achala
    Araki, Tetsuro
    Dako, Farouk
    Dave, Jaydev K.
    Perez, Raul Porto
    Xu, Dongming
    Nachiappan, Arun C.
    Barbosa Jr, Eduardo Mortani
    Noel, Peter
    Litt, Harold
    Knollman, Friedrich
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 11
  • [5] Pediatric Applications of Photon-Counting Detector CT
    Cao, Joseph
    Bache, Steve
    Schwartz, Fides R.
    Frush, Donald
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (04) : 580 - 589
  • [6] Photon-Counting Detector CT
    Marth, Adrian A.
    Goller, Sophia S.
    Kajdi, Georg W.
    Marcus, Roy P.
    Sutter, Reto
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 545 - 553
  • [7] Image Quality and Radiation Dose of Contrast-Enhanced Chest-CT Acquired on a Clinical Photon-Counting Detector CT vs. Second-Generation Dual-Source CT in an Oncologic Cohort: Preliminary Results
    Hagen, Florian
    Walder, Lukas
    Fritz, Jan
    Gutjahr, Ralf
    Schmidt, Bernhard
    Faby, Sebastian
    Bamberg, Fabian
    Schoenberg, Stefan
    Nikolaou, Konstantin
    Horger, Marius
    TOMOGRAPHY, 2022, 8 (03) : 1466 - 1476
  • [8] Task transfer function measurement of monoenergetic CT in energy-integrated detector CT and photon-counting detector CT, based on tasks using iodinated rod and wire phantoms
    Ohashi, Kazuya
    Ichikawa, Katsuhiro
    Kitera, Nobuo
    Watanabe, Seita
    Kawashima, Hiroki
    Kawai, Tatsuya
    Hiwatashi, Akio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2025, 130
  • [9] Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT
    Cundari, Giulia
    Deilmann, Philipp
    Mergen, Victor
    Ciric, Kristina
    Eberhard, Matthias
    Jungblut, Lisa
    Alkadhi, Hatem
    Higashigaito, Kai
    ACADEMIC RADIOLOGY, 2024, 31 (01) : 212 - 220
  • [10] Optimizing Chest CT With Photon-counting Detector Technology: Comparison to Established Energy-integrating Detector CT Protocols
    Alarab, N.
    Guo, J.
    Atha, J.
    Sieren, J. C.
    Puliyakote, A. S. Kizhakke
    Hoffman, E. A.
    Abadi, E.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209