Early detection of deteriorating patients in general wards through continuous contactless vital signs monitoring

被引:2
|
作者
Yadav, Ambuj [1 ]
Dandu, Himanshu [1 ]
Parchani, Gaurav [2 ]
Chokalingam, Kumar [2 ]
Kadambi, Pooja [2 ]
Mishra, Rajesh [2 ]
Jahan, Ahsina [2 ]
Teboul, Jean-Louis [3 ]
Latour, Jos M. [4 ]
机构
[1] King Georges Med Univ, Dept Med, Lucknow, India
[2] Turtle Shell Technol Pvt Ltd, Dept Clin Res, Bengaluru, India
[3] Paris Saclay Univ, Paris Saclay Med Sch, Le Kremlin Bicetre, France
[4] Univ Plymouth, Fac Hlth, Plymouth, England
来源
FRONTIERS IN MEDICAL TECHNOLOGY | 2024年 / 6卷
关键词
Early Warning System (EWS); remote; contactless; continuous; monitoring; general ward; ballistocardiography; HEALTH-CARE WORKERS; SHORTAGE; RISK; UNIT;
D O I
10.3389/fmedt.2024.1436034
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective To assess the efficacy of continuous contactless vital signs monitoring with an automated Early Warning System (EWS) in detecting clinical deterioration among patients in general wards.Methods A prospective observational cohort study was conducted in the medical unit of a tertiary care hospital in India, involving 706 patients over 84,448 monitoring hours. The study used a contactless ballistocardiography system (Dozee system) to continuously monitor heart rate, respiratory rate, and blood pressure. The study assessed total, mean, and median alerts at 24, 48, 72, 96, 120 h, and length of stay (LOS) before patient deterioration or discharge. It analyzed alert sensitivity and specificity, average time from initial alert to deterioration, and healthcare practitioners (HCP) activity. Study was registered with the Clinical Trials Registry-India CTRI/2022/10/046404.Results Out of 706 patients, 33 (5%) experienced clinical deterioration, while 673 (95%) did not. The deterioration group consistently had a higher number of alerts compared to those who were discharged normally, across all time-points. On average, the time between the initial alert and clinical deterioration was 16 h within the last 24 h preceding the event. The sensitivity of the Dozee-EWS varied between 67% and 94%. HCP spend 10% of their time on vital signs check and documentation.Conclusions This study suggests that utilizing contactless continuous vital signs monitoring with Dozee-EWS in general ward holds promise for enhancing the early detection of clinical deterioration. Further research is essential to evaluate the effectiveness across a wider range of clinical settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Improved inpatient deterioration detection in general wards by using time-series vital signs
    Chang-Fu Su
    Shu-I Chiu
    Jyh-Shing Roger Jang
    Feipei Lai
    Scientific Reports, 12
  • [22] SUNSHINE_eHealth: continuous monitoring of vital signs for early detection of clinical deterioration in oncological patients with high risk for complications
    Modesti, M.
    Ruinelli, L.
    Bunger, N.
    Mitrovic, S.
    Kopycinski, N.
    Lerch, E.
    Ciliberti, E.
    Zanon, M.
    Pascale, M.
    Wannesson, L.
    Mestre, R. Pereira
    SWISS MEDICAL WEEKLY, 2022, 152 : 20S - 20S
  • [23] Early recognition of deteriorating patients on surgical wards
    Douw, G.
    Huisman-de Waal, G.
    van Zanten, A. R. H.
    van der Hoeven, H.
    Schoonhoven, L.
    JOURNAL OF ADVANCED NURSING, 2016, 72 : 44 - 44
  • [24] Contactless face video based vital signs detection framework for continuous health monitoring using feature optimization and hybrid neural network
    Jalaja, Anju Anil
    Kavitha, Maruthai
    BIOTECHNOLOGY AND BIOENGINEERING, 2024, 121 (04) : 1191 - 1215
  • [25] Contactless Patient Monitoring for General Wards: A Systematic Technology Review
    Naziyok, Tolga P.
    Zeleke, Atinkut A.
    Roehrig, Rainer
    EXPLORING COMPLEXITY IN HEALTH: AN INTERDISCIPLINARY SYSTEMS APPROACH, 2016, 228 : 707 - 711
  • [26] Development of an Early Detection and Monitoring System for Deteriorating Patients
    Hwang, Min-A
    Jo, Eun-Mi
    Yoon, Hyeri
    Suh, Dong In
    MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 1055 - 1055
  • [27] Demo: Contactless Device for Monitoring On-Bed Activities and Vital Signs
    Clemente, Jose
    Li, Fangyu
    Valero, Maria
    Song, WenZhan
    2019 IEEE INTERNATIONAL CONFERENCE ON SMART COMPUTING (SMARTCOMP 2019), 2019, : 472 - 474
  • [28] Contactless Vital Signs Monitoring by mmWave Efficient Modulatorless Tracking Radar
    Ahmad, Wael A.
    Lu, Jeng-Hau
    Sutbas, Batuhan
    Ng, Herman Jalli
    Kissinger, Dietmar
    2021 IEEE GLOBAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INTERNET OF THINGS (GCAIOT), 2021, : 142 - 146
  • [29] Engagement-Free and Contactless Bed Occupancy and Vital Signs Monitoring
    Song, Yingjian
    Li, Bingnan
    Luo, Dan
    Xie, Zaipeng
    Phillips, Bradley G.
    Ke, Yuan
    Song, Wenzhan
    IEEE INTERNET OF THINGS JOURNAL, 2024, 11 (05): : 7935 - 7947
  • [30] Contactless radar based vital signs parameter estimation for sleep monitoring
    van Meulen, F. B.
    Kortelainen, J. M.
    Hirvonen, M.
    van Dijk, J. P.
    Plomp, J.
    Overeem, S.
    JOURNAL OF SLEEP RESEARCH, 2022, 31