Early detection of deteriorating patients in general wards through continuous contactless vital signs monitoring

被引:2
|
作者
Yadav, Ambuj [1 ]
Dandu, Himanshu [1 ]
Parchani, Gaurav [2 ]
Chokalingam, Kumar [2 ]
Kadambi, Pooja [2 ]
Mishra, Rajesh [2 ]
Jahan, Ahsina [2 ]
Teboul, Jean-Louis [3 ]
Latour, Jos M. [4 ]
机构
[1] King Georges Med Univ, Dept Med, Lucknow, India
[2] Turtle Shell Technol Pvt Ltd, Dept Clin Res, Bengaluru, India
[3] Paris Saclay Univ, Paris Saclay Med Sch, Le Kremlin Bicetre, France
[4] Univ Plymouth, Fac Hlth, Plymouth, England
来源
FRONTIERS IN MEDICAL TECHNOLOGY | 2024年 / 6卷
关键词
Early Warning System (EWS); remote; contactless; continuous; monitoring; general ward; ballistocardiography; HEALTH-CARE WORKERS; SHORTAGE; RISK; UNIT;
D O I
10.3389/fmedt.2024.1436034
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective To assess the efficacy of continuous contactless vital signs monitoring with an automated Early Warning System (EWS) in detecting clinical deterioration among patients in general wards.Methods A prospective observational cohort study was conducted in the medical unit of a tertiary care hospital in India, involving 706 patients over 84,448 monitoring hours. The study used a contactless ballistocardiography system (Dozee system) to continuously monitor heart rate, respiratory rate, and blood pressure. The study assessed total, mean, and median alerts at 24, 48, 72, 96, 120 h, and length of stay (LOS) before patient deterioration or discharge. It analyzed alert sensitivity and specificity, average time from initial alert to deterioration, and healthcare practitioners (HCP) activity. Study was registered with the Clinical Trials Registry-India CTRI/2022/10/046404.Results Out of 706 patients, 33 (5%) experienced clinical deterioration, while 673 (95%) did not. The deterioration group consistently had a higher number of alerts compared to those who were discharged normally, across all time-points. On average, the time between the initial alert and clinical deterioration was 16 h within the last 24 h preceding the event. The sensitivity of the Dozee-EWS varied between 67% and 94%. HCP spend 10% of their time on vital signs check and documentation.Conclusions This study suggests that utilizing contactless continuous vital signs monitoring with Dozee-EWS in general ward holds promise for enhancing the early detection of clinical deterioration. Further research is essential to evaluate the effectiveness across a wider range of clinical settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Continuous vital sign monitoring of patients recovering from surgery on general wards: a narrative review
    Khanna, Ashish K.
    Flick, Moritz
    Saugel, Bernd
    BRITISH JOURNAL OF ANAESTHESIA, 2025, 134 (02) : 501 - 509
  • [12] A controlled trial of electronic automated advisory vital signs monitoring in general hospital wards
    Bellomo, Rinaldo
    Ackerman, Michael
    Bailey, Michael
    Beale, Richard
    Clancy, Greg
    Danesh, Valerie
    Hvarfner, Andreas
    Jimenez, Edgar
    Konrad, David
    Lecardo, Michele
    Pattee, Kimberly S.
    Ritchie, Josephine
    Sherman, Kathie
    Tangkau, Peter
    CRITICAL CARE MEDICINE, 2012, 40 (08) : 2349 - 2361
  • [13] Cost utility analysis of continuous and intermittent versus intermittent vital signs monitoring in patients admitted to surgical wards
    Javanbakht, Mehdi
    Mashayekhi, Atefeh
    Trevor, Miranda
    Hemami, Mohsen Rezaei
    Downey, Candice L.
    Branagan-Harris, Michael
    Atkinson, Jowan
    JOURNAL OF MEDICAL ECONOMICS, 2020, 23 (07) : 728 - 736
  • [14] Editorial for Special Issue: Contactless Vital Signs Monitoring
    de Haan, Gerard
    Verkruysse, Wim
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [15] Effectiveness of continuous or intermittent vital signs monitoring in preventing adverse events on general wards: a systematic review and meta-analysis
    Cardona-Morrell, M.
    Prgomet, M.
    Turner, R. M.
    Nicholson, M.
    Hillman, K.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (10) : 806 - 824
  • [16] Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
    Leenen, Jobbe P. L.
    Dijkman, Eline M.
    van Dijk, Joris D.
    van Westreenen, Henderik L.
    Kalkman, Cor
    Schoonhoven, Lisette
    Patijn, Gijsbert A.
    BMJ OPEN, 2021, 11 (02):
  • [17] Continuous versus intermittent vital signs monitoring in patients admitted to surgical wards: a cluster-randomised, controlled trial
    Downey, C.
    Randell, R.
    Brown, J.
    Jayne, D.
    BRITISH JOURNAL OF SURGERY, 2018, 105 : 200 - 200
  • [18] Postanesthesia care by remote monitoring of vital signs in surgical wards
    Boer, Christa
    Touw, Hugo R.
    Loer, Stephan A.
    CURRENT OPINION IN ANESTHESIOLOGY, 2018, 31 (06) : 716 - 722
  • [19] Seismocardiography-based detection of heartbeats for continuous monitoring of vital signs
    Cocconcelli, Federico
    Mora, Niccolo
    Matrella, Guido
    Ciampolini, Paolo
    2019 11TH COMPUTER SCIENCE AND ELECTRONIC ENGINEERING (CEEC), 2019, : 53 - 58
  • [20] Improved inpatient deterioration detection in general wards by using time-series vital signs
    Su, Chang-Fu
    Chiu, Shu-, I
    Jang, Jyh-Shing Roger
    Lai, Feipei
    SCIENTIFIC REPORTS, 2022, 12 (01)