Effects of building load characteristics on heating performance of the medium-deep U-type borehole heat exchanger coupled heat pumps: A coupled dynamic simulation

被引:0
|
作者
Huang, Shuai [1 ,2 ]
Lin, Duotong [1 ,2 ]
Dong, Jiankai [1 ,2 ]
Li, Ji [3 ]
机构
[1] Harbin Inst Technol, Sch Architecture & Design, Harbin 150090, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Cold Reg Urban & Rural Human Settlement En, Harbin 150090, Peoples R China
[3] China Acad Bldg Res, Inst Bldg Environm & Energy, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
Deep geothermal energy; Building loads; Heat pumps; Coupling simulation; MDUBHE; BEND PIPE; EFFICIENCY; CAPACITY;
D O I
10.1016/j.apenergy.2024.124405
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The medium-deep U-type borehole heat exchanger (MDUBHE) coupled ground source heat pump to extract deep geothermal energy for heating buildings is a novel and efficient system. However, the current research focuses on the heat transfer of the main apparatus MDUBHE and ignores the dynamic coupling and matching between the system and the building load, resulting in the effect of the building load characteristics on the system performance and the rock-soil temperature is still unclear. Therefore, this study first integrated the MDUBHE model into the Trnsys platform to realize the coupled simulation of building loads with the MDUBHE system. Based on the integrated novel platform, the effect mechanism of building load characteristics on the system's operation and the rock-soil temperature is revealed. The results show that the water temperature, flow rate, heating capacity, and system efficiency under dynamic actual load conditions are significantly different compared to constant building loads. The inlet and outlet temperatures varied in the ranges of 15.4-34.5 degrees C and 20.7-40.5 degrees C, respectively, and the flow rates on the user side and the ground source side varied in the ranges of 4.6x10(4)-2.2x10(5) kg/h and 3.7x10(4)-1.6x10(5) kg/h, respectively. In addition, the heating capacity varies from 0.1x10(3)-3.6x10(3) GJ, and the unit performance varies hourly. Furthermore, the soil temperatures also respond to changes in the actual building loads, but the variation is insignificant with increasing radial distance due to heat conduction. This study provides a foundation for matching the system capacity with the building loads.
引用
收藏
页数:15
相关论文
共 45 条
  • [21] Thermal performance of a deep borehole heat exchanger: Insights from a synthetic coupled heat and flow model
    Le Lous, Morgan
    Larroque, Francois
    Dupuy, Alain
    Moignard, Adeline
    GEOTHERMICS, 2015, 57 : 157 - 172
  • [22] Numerical investigation on the performance, sustainability, and efficiency of the deep borehole heat exchanger system for building heating
    Chen, Chaofan
    Shao, Haibing
    Naumov, Dmitri
    Kong, Yanlong
    Tu, Kun
    Kolditz, Olaf
    GEOTHERMAL ENERGY, 2019, 7 (01)
  • [23] Numerical investigation on the performance, sustainability, and efficiency of the deep borehole heat exchanger system for building heating
    Chaofan Chen
    Haibing Shao
    Dmitri Naumov
    Yanlong Kong
    Kun Tu
    Olaf Kolditz
    Geothermal Energy, 7
  • [24] Thermal performance analysis on the composition attributes of deep coaxial borehole heat exchanger for building heating
    Huang, Yibin
    Zhang, Yanjun
    Xie, Yangyang
    Zhang, Yu
    Gao, Xuefeng
    ENERGY AND BUILDINGS, 2020, 221 (221)
  • [25] In-situ test and numerical investigation on the long-term performance of deep borehole heat exchanger coupled heat pump heating system
    Liu, Bin
    Wang, Jiangfeng
    Li, Hongyan
    Liu, Jian
    Wang, Pengtao
    Cai, Wanlong
    Sun, Xianpeng
    Chen, Chaofan
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [26] Numerical investigation of the deep borehole heat exchanger in medium-depth geothermal heat pump system for building space heating
    Wang, Xiaoyan
    Su, Yanmin
    Liu, Guang
    Ni, Long
    ENERGY AND BUILDINGS, 2024, 304
  • [27] Numerical investigation of the deep borehole heat exchanger in medium-depth geothermal heat pump system for building space heating
    Wang, Xiaoyan
    Su, Yanmin
    Liu, Guang
    Ni, Long
    Energy and Buildings, 2024, 304
  • [28] Evaluation of the long-term performance of the deep U-type borehole heat exchanger on different geological parameters using the Taguchi method
    Jiang, Jinghua
    Wang, Fenghao
    Yang, Xiong
    Zhang, Yuping
    Deng, Jiewen
    Wei, Qingpeng
    Cai, Wanlong
    Chen, Chaofan
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [29] Heating and storage of medium-deep borehole heat exchangers: Analysis of operational characteristics via an optimized analytical solution model
    Ma, Jiuchen
    Wang, Huan
    Li, Yang
    Ren, Jiawei
    Sun, Hanqi
    Du, Shikang
    Wen, Hang
    JOURNAL OF ENERGY STORAGE, 2024, 90
  • [30] Performance analysis of a residential heating system using borehole heat exchanger coupled with solar assisted PV/T heat pump
    Yao, Jian
    Liu, Wenjie
    Zhang, Lu
    Tian, Binshou
    Dai, Yanjun
    Huang, Mingjun
    RENEWABLE ENERGY, 2020, 160 (160) : 160 - 175