A new method for the rapid identification of external water types in rainwater pipeline networks using UV-Vis absorption spectroscopy

被引:0
|
作者
Chen, Xiaowei [1 ]
Zhao, Nanjing [1 ]
Zhu, Wanjiang [1 ,2 ]
Yin, Gaofang [1 ]
Jia, Renqing [1 ]
Yang, Ruifang [1 ]
Ma, Mingjun [1 ]
机构
[1] Chinese Acad Sci, Key Lab Environm Opt &Technol, Anhui Inst Opt & Fine Mech, Hefei, Peoples R China
[2] Univ Sci & Technol China, Hefei, Peoples R China
关键词
UV-Vis absorption spectroscopy; Generative Adversarial Network; Multiplicative scatter correction; Variational mode decomposition; Long short-term memory; Rapid identification; External water types in rainwater; QUANTIFICATION; SURFACE;
D O I
10.1016/j.saa.2024.124968
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Ultraviolet-visible (UV-Vis) absorption spectroscopy, due to its high sensitivity and capability for real-time online monitoring, is one of the most promising tools for the rapid identification of external water in rainwater pipe networks. However, difficulties in obtaining actual samples lead to insufficient real samples, and the complex composition of wastewater can affect the accurate traceability analysis of external water in rainwater pipe networks. In this study, a new method for identifying external water in rainwater pipe networks with a small number of samples is proposed. In this method, the Generative Adversarial Network (GAN) algorithm was initially used to generate spectral data from the absorption spectra of water samples; subsequently, the multiplicative scatter correction (MSC) algorithm was applied to process the UV-Vis absorption spectra of different types of water samples; following this, the Variational Mode Decomposition (VMD) algorithm was employed to decompose and recombine the spectra after MSC; and finally, the long short-term memory (LSTM) algorithm was used to establish the identification model between the recombined spectra and the water source types, and to determine the optimal number of decomposed spectra K. The research results show that when the number of decomposed spectra K is 5, the identification accuracy for different sources of domestic sewage, surface water, and industrial wastewater is the highest, with an overall accuracy of 98.81%. Additionally, the performance of this method was validated by mixed water samples (combinations of rainwater and domestic sewage, rainwater and surface water, and rainwater and industrial wastewater). The results indicate that the accuracy of the proposed method in identifying the source of external water in rainwater reaches 98.99%, with detection time within 10 s. Therefore, the proposed method can become a potential approach for rapid identification and traceability analysis of external water in rainwater pipe networks.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Identification of geographical and botanical origin of Mediterranean honeys using UV-vis spectroscopy and multivariate statistical analysis
    Dimakopoulou-Papazoglou, Dafni
    Ploskas, Nikolaos
    Koutsoumanis, Konstantinos
    Katsanidis, Eugenios
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2024, 18 (5) : 3923 - 3934
  • [32] A new kinetic method using UV-VIS spectrophotometry for determination of caffeic acid in propolis
    Kostic, Danijela A.
    Mitic, Snezana
    Mitic, Milan
    Marinkovic, Emilija Pecev
    Misic, Ivana Rasic
    Arsic, Biljana
    Stojanovic, Gordana
    JOURNAL OF FOOD SAFETY AND FOOD QUALITY-ARCHIV FUR LEBENSMITTELHYGIENE, 2019, 70 (04): : 111 - 116
  • [33] EVALUATION OF LOW-COST UV-VIS SPECTROSCOPY FOR MEASURING NITRATE USING SYNTHETIC WATER SAMPLES
    Carter, Joe Barrett
    Sarkees, Ashley
    Singh, A.
    Bean, Eban
    JOURNAL OF THE ASABE, 2023, 66 (04): : 929 - 941
  • [34] An Improved-Bagging Model for Water Chemical Oxygen Demand Measurements Using UV-Vis Spectroscopy
    Li, Jingwei
    Pan, Sisi
    Bian, Jie
    Jiang, Wei
    IEEE Access, 2021, 9 : 161834 - 161845
  • [35] Validation of a Quantitative Method Determination of Estradiol in Pharmaceutical Products using UV-Vis Molecular Absorption Spectrometry
    Popescu, Ileana Liliana
    Aboul-Enein, Hassan Y.
    Tanase, Ion G.
    Ghica, Ioana
    Bala, Camelia
    ANALYTICAL LETTERS, 2008, 41 (18) : 3272 - 3296
  • [36] An Improved-Bagging Model for Water Chemical Oxygen Demand Measurements Using UV-Vis Spectroscopy
    Li, Jingwei
    Pan, Sisi
    Bian, Jie
    Jiang, Wei
    IEEE ACCESS, 2021, 9 : 161834 - 161845
  • [37] A direct and rapid method for determination of total iron in environmental samples and hydrometallurgy using UV-Vis spectrophotometry
    Cheng, Fei
    Zhang, Taiming
    Yang, Chunhua
    Zhu, Hongqiu
    Li, Yonggang
    Sun, Tao
    Zhou, Can
    MICROCHEMICAL JOURNAL, 2022, 179
  • [38] CHARACTERIZATION OF CdSexS1-x QUANTUM DOTS USING XRD, UV-VIS ABSORPTION AND RAMAN SPECTROSCOPY MEASUREMENTS
    Kumar, Jitender
    Madan, Shikha
    Madhwal, Devinder
    Singh, Inderpreet
    Bhatnagar, P. K.
    Mathur, P. C.
    Islam, S. S.
    INTERNATIONAL JOURNAL OF NANOSCIENCE, 2012, 11 (02)
  • [39] Non-contact assessment of COD and turbidity concentrations in water using diffuse reflectance UV-Vis spectroscopy
    Agustsson, Jon
    Akermann, Oliver
    Barry, D. Andrew
    Rossi, Luca
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2014, 16 (08) : 1897 - 1902
  • [40] Two conformers of a tyrosine kinase inhibitor (AG-1478) disclosed using simulated UV-Vis absorption spectroscopy
    Khattab, Muhammad
    Chatterjee, Subhojyoti
    Clayton, Andrew H. A.
    Wang, Feng
    NEW JOURNAL OF CHEMISTRY, 2016, 40 (10) : 8296 - 8304