A new method for the rapid identification of external water types in rainwater pipeline networks using UV-Vis absorption spectroscopy

被引:0
|
作者
Chen, Xiaowei [1 ]
Zhao, Nanjing [1 ]
Zhu, Wanjiang [1 ,2 ]
Yin, Gaofang [1 ]
Jia, Renqing [1 ]
Yang, Ruifang [1 ]
Ma, Mingjun [1 ]
机构
[1] Chinese Acad Sci, Key Lab Environm Opt &Technol, Anhui Inst Opt & Fine Mech, Hefei, Peoples R China
[2] Univ Sci & Technol China, Hefei, Peoples R China
关键词
UV-Vis absorption spectroscopy; Generative Adversarial Network; Multiplicative scatter correction; Variational mode decomposition; Long short-term memory; Rapid identification; External water types in rainwater; QUANTIFICATION; SURFACE;
D O I
10.1016/j.saa.2024.124968
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Ultraviolet-visible (UV-Vis) absorption spectroscopy, due to its high sensitivity and capability for real-time online monitoring, is one of the most promising tools for the rapid identification of external water in rainwater pipe networks. However, difficulties in obtaining actual samples lead to insufficient real samples, and the complex composition of wastewater can affect the accurate traceability analysis of external water in rainwater pipe networks. In this study, a new method for identifying external water in rainwater pipe networks with a small number of samples is proposed. In this method, the Generative Adversarial Network (GAN) algorithm was initially used to generate spectral data from the absorption spectra of water samples; subsequently, the multiplicative scatter correction (MSC) algorithm was applied to process the UV-Vis absorption spectra of different types of water samples; following this, the Variational Mode Decomposition (VMD) algorithm was employed to decompose and recombine the spectra after MSC; and finally, the long short-term memory (LSTM) algorithm was used to establish the identification model between the recombined spectra and the water source types, and to determine the optimal number of decomposed spectra K. The research results show that when the number of decomposed spectra K is 5, the identification accuracy for different sources of domestic sewage, surface water, and industrial wastewater is the highest, with an overall accuracy of 98.81%. Additionally, the performance of this method was validated by mixed water samples (combinations of rainwater and domestic sewage, rainwater and surface water, and rainwater and industrial wastewater). The results indicate that the accuracy of the proposed method in identifying the source of external water in rainwater reaches 98.99%, with detection time within 10 s. Therefore, the proposed method can become a potential approach for rapid identification and traceability analysis of external water in rainwater pipe networks.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A New Technique to Measure Interfacial Tension of Transformer Oil using UV-Vis Spectroscopy
    Abu Bakar, Norazhar
    Abu-Siada, A.
    Islam, S.
    El-Naggar, M. F.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) : 1275 - 1282
  • [22] Identification of adulteration in ground roasted coffees using UV-Vis spectroscopy and SPA-LDA
    de Carvalho Polari Souto, Urijatan Teixeira
    Barbosa, Mayara Ferreira
    Dantas, Hebertty Vieira
    de Pontes, Aline Santos
    Lyra, Wellington da Silva
    Goncalves Dias Diniz, Paulo Henrique
    Ugulino de Araujo, Mario Cesar
    da Silva, Edvan Cirino
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2015, 63 (02) : 1037 - 1041
  • [23] A New Method for the Determination of Molecular Diffusion Coefficient in Polymer Films by Simple UV-Vis Spectroscopy
    Lova, Paola
    Meghad, Heba
    Comoretto, Davide
    9TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF ADVANCED MATERIALS (ICSAAM 2019), 2019, 2196
  • [24] Thermodynamics of 4-methylphenol dissociation in water at high temperature using UV-Vis spectroscopy
    De Leo, LPM
    Bianchi, HL
    Fernández-Prini, RJ
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2002, 34 (09): : 1467 - 1479
  • [25] Study on Complex Formation of Quercetin Reacting with Cu2+ Using UV-Vis Absorption Spectroscopy
    Xue Jun-peng
    Li Ping
    Wang Qi-ming
    Zhao Wei
    Wu Da-cheng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (09) : 2539 - 2542
  • [26] In situ characterisation of absorbing species in stationary premixed flat flames using UV-Vis absorption spectroscopy
    Bauer, Florian J.
    Degenkolb, Michael U. J.
    Huber, Franz J. T.
    Will, Stefan
    APPLIED PHYSICS B-LASERS AND OPTICS, 2021, 127 (08):
  • [27] Characteristic Wavelength Selection and Surrogate Monitoring for UV-Vis Absorption Spectroscopy-Based Water Quality Sensing
    Chen, Chenyu
    Luo, Meiyu
    Wang, Wenyu
    Ping, Yang
    Li, Hongming
    Chen, Siyuan
    Liang, Qian
    WATER, 2025, 17 (03)
  • [28] Fish farming water quality monitored by optical analysis: The potential application of UV-Vis absorption and fluorescence spectroscopy
    Figueiro, C. S. M.
    Bastos de Oliveira, D.
    Russo, M. R.
    Caires, A. R. L.
    Rojas, S. S.
    AQUACULTURE, 2018, 490 : 91 - 97
  • [29] Experimental Study on Rapid Detection of Various Organophosphorus Pesticides in Water by UV-Vis Spectroscopy and Parallel Factor Analysis
    Huang Li
    Ma Rui-jun
    Chen Yu
    Cai Xiang
    Yan Zhen-feng
    Tang Hao
    Li Yan-fen
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (11) : 3452 - 3460
  • [30] Green analytical method for COD determination using UV-Vis spectroscopy combined with machine learning
    Santos, Pierre A.
    Santos, Poliana M.
    CHEMICAL PAPERS, 2025, : 2453 - 2460