In-house protocol for fully guided zygomatic implant surgery and prosthesis repositioning A technical note

被引:0
|
作者
Bertos-Quilez, Jorge [1 ]
Pindaros-Georgios, Foskolos [1 ]
Ragucci, Gian Maria [1 ]
Valls-Ontanon, Adaia [1 ,2 ]
Liaropoulou, Yolanda-Maria [1 ]
Paternostro-Betancourt, Daniel [1 ]
Hernandez-Alfaro, Federico [1 ,2 ]
机构
[1] Univ Int Catalunya, Dept Oral & Maxillofacial Surg, Josep Trueta S-N, Barcelona 08195, Spain
[2] Teknon Med Ctr, Inst Maxillofacial Surg, Barcelona, Spain
来源
关键词
implantology; prosthodontics; PROVISIONAL RESTORATIONS; BOND STRENGTH; POLYMERIZATION; ROUGHNESS; CROWN;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The present study aims to describe an in-house protocol for fully guided zygomatic implant surgery and prosthesis repositioning. Materials and methods: Four extramaxillary zygomatic dental implants (ZIs) were placed in one patient. The preoperative phase included digital planning, through which a surgical guide was designed and created. The analysis of the accuracy of guided surgery and the guided prosthesis repositioning was carried out by superimposing the digital planning with the final postsurgical implant positioning through CbCT. The radiologic evaluation included implant angular deviation, entrance and exit deviation, platform deviation, and apex apicocoronal and mesiodistal deviation. The prosthetic evaluation was performed in three directions: buccopalatal, apicocoronal, and mesiodistal. Results: All the ZIs successfully osseointegrated after 3 months of healing, with no complications. The mean axial angular implant deviation was 0.52 +/- 0.36 degrees, and the mean implant depth deviation was 0.47 +/- 0.28 mm. The entrance and exit deviation of the implants was 0.74 +/- 0.42 mm and 0.7 +/- 0.43 mm, respectively. The virtual prosthesis was superimposed and compared with the standard tessellation language file of the provisional polymethyl methacrylate prosthesis at the level of the first molars and central incisors; the mean buccopalatal deviation was 0.6 +/- 0.035 mm, the mean apicocoronal deviation was 0.65 +/- 0.11 mm, and the mean mesiodistal deviation was 0.3 +/- 0.07 mm. Conclusions: According to the results obtained in this first case of the present case series, careful and meticulous digital planning based on the correct pros-thetic parameters can safely guide the performance of surgery.
引用
收藏
页数:100
相关论文
共 50 条
  • [31] New Protocol for Skin Landmark Registration in Image-Guided Neurosurgery: Technical Note
    Gerard, Ian J.
    Hall, Jeffery A.
    Mok, Kelvin
    Collins, D. Louis
    OPERATIVE NEUROSURGERY, 2015, 11 (03) : 376 - 380
  • [32] Computer-aided flapless implant surgery and immediate loading. A technical note
    Baruffaldi A.
    Poli P.P.
    Baruffaldi A.
    Giberti L.
    Pigozzo M.
    Maiorana C.
    Oral and Maxillofacial Surgery, 2016, 20 (3) : 313 - 319
  • [33] Immediate implant-retained prosthetic obturation after maxillectomy based on zygomatic implant placement by 3D-guided surgery: a cadaver study
    Vosselman, N.
    Glas, H. H.
    de Visscher, S. A. H. J.
    Kraeima, J.
    Merema, B. J.
    Reintsema, H.
    Raghoebar, G. M.
    Witjes, M. J. H.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [34] Immediate implant-retained prosthetic obturation after maxillectomy based on zygomatic implant placement by 3D-guided surgery: a cadaver study
    N. Vosselman
    H. H. Glas
    S. A. H. J. de Visscher
    J. Kraeima
    B. J. Merema
    H. Reintsema
    G. M. Raghoebar
    M. J. H. Witjes
    International Journal of Implant Dentistry, 7
  • [35] Zygoma Anatomy-Guided Approach "Scarf Graft" for Prevention of Soft Tissue Dehiscence Around Zygomatic Implants: Technical Note
    Aparicio, Carlos
    Antonio, Sanz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (02) : E21 - E26
  • [36] Autonomous robotic surgery for zygomatic implant placement and immediately loaded implant-supported full-arch prosthesis: a preliminary research (vol 9, 12, 2023)
    Li, Changjian
    Wang, Menglin
    Deng, Huanze
    Li, Shumao
    Fang, Xinyu
    Liang, Yijie
    Ma, Xihua
    Zhang, Yue
    Li, Yanfeng
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [37] Comparison of the Accuracy of Pilot Drill-Guided and Fully Guided Implant Surgery With Dynamic Navigation: In Vitro Model Study
    Bilge, Suheyb
    Demetoglu, Umut
    Aslan, Senol
    Simsek, Hasan Onur
    JOURNAL OF ORAL IMPLANTOLOGY, 2025, 51 (01) : 105 - 110
  • [38] Accuracy evaluation of partially guided and fully guided templates applied to implant surgery of anterior teeth: A randomized controlled trial
    Lou, Fangzhi
    Rao, Pengcheng
    Zhang, Maorui
    Luo, Shihong
    Lu, Shi
    Xiao, Jingang
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (01) : 117 - 130
  • [39] CAD/CAM-guided implant surgery and fabrication of an immediately loaded prosthesis for a partially edentulous patient
    Marchack, Christopher B.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : 389 - 394
  • [40] Fluorescence-guided thoracoscopic surgery for postoperative chylothorax: A technical note with video vignette
    Kuo, Tzu-Wei
    Tseng, Shih-Kang
    Chou, Pin -Li
    Cheng, Chuan
    Chu, Sung -Yu
    Chao, Yin -Kai
    ASIAN JOURNAL OF SURGERY, 2024, 47 (06) : 2623 - 2624