In-house protocol for fully guided zygomatic implant surgery and prosthesis repositioning A technical note

被引:0
|
作者
Bertos-Quilez, Jorge [1 ]
Pindaros-Georgios, Foskolos [1 ]
Ragucci, Gian Maria [1 ]
Valls-Ontanon, Adaia [1 ,2 ]
Liaropoulou, Yolanda-Maria [1 ]
Paternostro-Betancourt, Daniel [1 ]
Hernandez-Alfaro, Federico [1 ,2 ]
机构
[1] Univ Int Catalunya, Dept Oral & Maxillofacial Surg, Josep Trueta S-N, Barcelona 08195, Spain
[2] Teknon Med Ctr, Inst Maxillofacial Surg, Barcelona, Spain
来源
关键词
implantology; prosthodontics; PROVISIONAL RESTORATIONS; BOND STRENGTH; POLYMERIZATION; ROUGHNESS; CROWN;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The present study aims to describe an in-house protocol for fully guided zygomatic implant surgery and prosthesis repositioning. Materials and methods: Four extramaxillary zygomatic dental implants (ZIs) were placed in one patient. The preoperative phase included digital planning, through which a surgical guide was designed and created. The analysis of the accuracy of guided surgery and the guided prosthesis repositioning was carried out by superimposing the digital planning with the final postsurgical implant positioning through CbCT. The radiologic evaluation included implant angular deviation, entrance and exit deviation, platform deviation, and apex apicocoronal and mesiodistal deviation. The prosthetic evaluation was performed in three directions: buccopalatal, apicocoronal, and mesiodistal. Results: All the ZIs successfully osseointegrated after 3 months of healing, with no complications. The mean axial angular implant deviation was 0.52 +/- 0.36 degrees, and the mean implant depth deviation was 0.47 +/- 0.28 mm. The entrance and exit deviation of the implants was 0.74 +/- 0.42 mm and 0.7 +/- 0.43 mm, respectively. The virtual prosthesis was superimposed and compared with the standard tessellation language file of the provisional polymethyl methacrylate prosthesis at the level of the first molars and central incisors; the mean buccopalatal deviation was 0.6 +/- 0.035 mm, the mean apicocoronal deviation was 0.65 +/- 0.11 mm, and the mean mesiodistal deviation was 0.3 +/- 0.07 mm. Conclusions: According to the results obtained in this first case of the present case series, careful and meticulous digital planning based on the correct pros-thetic parameters can safely guide the performance of surgery.
引用
收藏
页数:100
相关论文
共 50 条
  • [1] Fully Guided Zygomatic Implant Surgery
    Rigo, Leone
    Tollardo, James
    Giammarinaro, Enrica
    Covani, Ugo
    Caso, Guerino
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (08) : 2867 - 2872
  • [2] Three-Dimensional Evaluation of the Accuracy of Zygomatic Implant Placement Through an In-House Fully Guided
    Hernandez-Alfaro, Federico
    Bertos-Quilez, Jorge
    Valls-Ontanon, Adaia
    Paternostro-Betancourt, Daniel
    Pindaros-Georgios, Foskolos
    Ragucci, Gian Maria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (04) : 747 - 756
  • [3] A modified protocol merging two published techniques for computer guided zygomatic implants surgery: a technical note
    Abouzeid, Omar Effat Mokhtar
    Gaber, Ramy M.
    Maergy, Haitham A.
    Hany, Hossam El-Dien
    Abdelmohsen, Karim M.
    Elkassaby, Marwa A.
    Taha, Moustafa M.
    BMC ORAL HEALTH, 2024, 24 (01):
  • [4] A Novel Approach to Guided Implant Surgery: A Technical Note
    Franchini, Federico
    Fuzzi, Massimo
    Leone, Renato
    Sorrentino, Roberto
    PROSTHESIS, 2022, 4 (04): : 524 - 539
  • [5] Zygomatic Implant Placement With Flapless Computer-Guided Surgery: A Proposed Clinical Protocol
    Schiroli, Guido
    Angiero, Francesca
    Silvestrini-Biavati, Armando
    Benedicenti, Stefano
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (12) : 2979 - 2989
  • [6] Simplifying Zygomatic Implant Site Preparation Using Ultrasonic Navigation: A Technical Note
    Pellegrino, Gerardo
    Tarsitano, Achille
    Taraschi, Valerio
    Vercellotti, Tomaso
    Marchetti, Claudio
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (03) : E67 - E71
  • [7] A Fully Guided Sequential Template Immediate Loading Protocol for Dual-Arch Implant Surgery
    Alruhailie, Lamia
    Zaidan, Aliyaa
    Alasmari, Abeer
    Raffa, Ossama
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2024, 16 : 167 - 177
  • [8] An experimental analysis of the stresses on the implant in an implant-tooth-supported prosthesis: A technical note
    Uysal, H
    Iplikcioglu, H
    Avci, M
    Bilir, OG
    Kural, O
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (01) : 118 - 124
  • [9] New protocol for in-house management of computer assisted orthognathic surgery
    Riu, Giacomo De
    Vaira, Luigi Angelo
    Ligas, Enrica
    Vaittinen, Veronica
    Spano, Giovanni
    Salzano, Giovanni
    Piombino, Pasquale
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2020, 58 (10): : E265 - E271
  • [10] Inferior alveolar nerve repositioning and securing in conjunction with dental implant placement: a technical note
    Deryabin, George
    Grybauskas, Simonas
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)