Image Quality and Radiation Exposure in Abdominal Angiography

被引:0
|
作者
Werncke, Thomas [1 ]
Becker, Lena S. [1 ]
Maschke, Sabine K. [1 ]
Hinrichs, Jan B. [2 ]
Meine, Timo C. H. [1 ]
Dewald, Cornelia L. A. [1 ]
Bruesch, Inga [3 ]
Rumpel, Regina [3 ]
Wacker, Frank K. [1 ]
Meyer, Bernhard C. [1 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] St Bernward Hosp, Dept Diagnost & Intervent Radiol & Neuroradiol, Hildesheim, Germany
[3] Hannover Med Sch, Inst Lab Anim Sci & Cent Anim Facil, Hannover, Germany
关键词
image quality; interventional radiology; radiation dose; animal study; phantom study; fluoroscopy; AIR GAPS; MANAGEMENT; REDUCTION; SYSTEM;
D O I
10.1097/RLI.0000000000001079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This phantom and animal pilot study aimed to compare image quality and radiation exposure between detector-dose-driven exposure control (DEC) and contrast-to-noise ratio (CNR)-driven exposure control (CEC) as functions of source-to-image receptor distance (SID) and collimation. Materials and Methods: First, an iron foil simulated a guide wire in a stack of polymethyl methacrylate and aluminum plates representing patient thicknesses of 15, 25, and 35 cm. Fluoroscopic images were acquired using 5 SIDs ranging from 100 to 130 cm and 2 collimations (full field of view, collimated field of view: 6 x 6 cm). The iron foil CNRs were calculated, and radiation doses in terms of air kerma rate were obtained and assessed using a multivariate regression. Second, 5 angiographic scenarios were created in 2 anesthetized pigs. Fluoroscopic images were acquired at 2 SIDs (110 and 130 cm) and both collimations. Two blinded experienced readers compared image quality to the reference image using full field of view at an SID of 110 cm. Air kerma rate was obtained and compared using t tests. Results: Using DEC, both CNR and air kerma rate increased significantly at longer SID and collimation below the air kerma rate limit. When using CEC, CNR was significantly less dependent of SID, collimation, and patient thickness. Air kerma rate decreased at longer SID and tighter collimation. After reaching the air kerma rate limit, CEC behaved similarly to DEC. In the animal study using DEC, image quality and air kerma rate increased with longer SID and collimation (P < 0.005). Using CEC, image quality was not significantly different than using longer SID or tighter collimation. Air kerma rate was not significantly different at longer SID but lower using collimation (P = 0.012). Conclusions: CEC maintains the image quality with varying SID and collimation stricter than DEC, does not increase the air kerma rate at longer SID and reduces it with tighter collimation. After reaching the air kerma rate limit, CEC and DEC perform similarly.
引用
收藏
页码:711 / 718
页数:8
相关论文
共 50 条
  • [1] Image quality in a low radiation exposure protocol for retrospectively gated coronary CT angiography
    Pflederer, T.
    Rudofsky, L.
    Marwan, M.
    Muschiol, G.
    Ropers, D.
    Daniel, W. G.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 248 - 248
  • [2] Influence of Heart Rate on Image Quality and Radiation Dose Exposure in Coronary CT Angiography
    Stocker, Thomas J.
    Leipsic, Jonathon
    Chen, Marcus Y.
    Achenbach, Stephan
    Knuuti, Juhani
    Newby, David
    Hausleiter, Joerg
    RADIOLOGY, 2021, 300 (03) : 701 - 703
  • [3] Impact of the scout view orientation on the radiation exposure and image quality in thoracic and abdominal CT
    S. Suntharalingam
    A. Wetter
    N. Guberina
    J. Theysohn
    A. Ringelstein
    T. Schlosser
    M. Forsting
    K. Nassenstein
    European Radiology, 2016, 26 : 4072 - 4079
  • [4] Impact of the scout view orientation on the radiation exposure and image quality in thoracic and abdominal CT
    Suntharalingam, S.
    Wetter, A.
    Guberina, N.
    Theysohn, J.
    Ringelstein, A.
    Schlosser, T.
    Forsting, M.
    Nassenstein, K.
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 4072 - 4079
  • [5] IMAGE QUALITY AND RADIATION EXPOSURE IN MAMMOGRAPHY
    WOLF, G
    KALLINGER, G
    ACTA MEDICA AUSTRIACA, 1984, 11 (02) : 62 - 62
  • [6] Image Quality and Radiation Exposure in Pediatric Cardiovascular CT Angiography From Different Injection Sites
    Yang, Ming
    Mo, Xu-Ming
    Jin, Ji-Yang
    Zhang, Jian
    Liu, Bin
    Wu, Min
    Teng, Gao-Jun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (02) : W117 - W122
  • [7] Outpatient facility dedicated to preparation for ct coronary angiography: impact on image quality and radiation exposure
    Slavich, G. A.
    Piccoli, G.
    Puppato, M.
    Grillone, S.
    Gasparini, D.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A108 - A108
  • [8] In vivo effectiveness of gadolinium filter for paediatric cardiac angiography in terms of image quality and radiation exposure
    Baldazzi, G
    Corazza, I
    Rossi, PL
    Testoni, G
    Bernardi, T
    Zannoli, R
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2002, 18 (03): : 109 - 113
  • [9] Radiation Exposure: Optimizing Image Quality or Image Utility?
    Tabriz, David
    Duncan, James
    JOURNAL OF PATIENT SAFETY, 2018, 14 (01) : 66 - 66
  • [10] Impact of a contrast-to-noise ratio driven and material specific exposure control on image quality and radiation exposure in angiography
    Werncke, Thomas
    Kemling, Marius
    Tashenov, Stanislav
    Hinrichs, Jan B.
    Meine, Timo C.
    Maschke, Sabine K.
    Kyriakou, Yiannis
    Wacker, Frank K.
    Meyer, Bernhard C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):