A Personalized Anisotropic Margin for Cervical Cancer Radiation Therapy Under the Guidance of Daily Iterative Cone-Beam Computed Tomography (iCBCT)

被引:0
|
作者
Xiao, Haonan [1 ,2 ]
Guo, Qiufen [3 ]
Ma, Junjie [1 ]
Chen, Jian [4 ]
Xie, Peng [3 ]
Yin, Yong [1 ]
机构
[1] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp & Inst, Dept Radiat Oncol & Phys, Jinan, Peoples R China
[2] Shandong Canc Hosp, Shandong Prov Key Med & Hlth Lab Pediat Canc Preci, Dept Radiat Oncol & Phys, Jinan, Peoples R China
[3] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp & Inst, Dept Radiat Oncol, Jinan, Peoples R China
[4] Univ South China, Sch Nucl Sci & Technol, Dept Nucl Sci & Technol, Hengyang, Peoples R China
关键词
intrafraction motion; varian ethos; motion management; online art; cervical cancer; PELVIC ORGAN MOTION; TARGET VOLUME; RADIOTHERAPY; IMPACT;
D O I
10.7759/cureus.69029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Online adaptive radiation therapy (ART) eliminates interfraction uncertainties by adaption before each treatment session. However, intrafraction motions still exist and could become more severe due to long treatment time. Large isotropic margins can ensure clinical target volume (CTV) coverage but at the cost of more organs at risk damage. In this study, we proposed a novel personalized anisotropic margin search algorithm for cervical cancer radiation therapy under the guidance of daily iterative cone-beam computed tomography (iCBCT) to find the optimal margin values for each patient, which achieves the smallest possible planning target volume (PTV) and maintains CTV coverage. Twenty-two online Ethos ART treatment sessions were included for analysis. Two iCBCT scans were taken in each session. The first one (iCBCT(1)) was taken after positioning, and the second one (iCBCT(2)) was taken before beam delivery. Corresponding CTV1 and CTV(2 )were contoured in the two scans. In each session, minimal isotropic margins were first searched by iteratively increasing the magnitude until the resulting PTViso covers 99% of CTV2. Afterward, the margin values in all six directions were decreased iteratively until CTV2 coverage was smaller than 99% to get the personalized margin and target volume PTVint. In addition, the uterus was considered separately, and different margins were found for it and the remaining CTV, respectively, to reduce the target volume of PTV(sep )further. PTViso, PTVint, and PTVsep were compared in terms of CTV2 coverage and absolute volume. The algorithm successfully generated PTViso, PTVint, and PTVsep for all online ART treatment sessions. The mean +/- SD values for PTViso5mm, PTViso10mm, PTViso15mm, PTVint, and PTVsep were 1,074.0 +/- 78.1, 1,519.5 +/- 100.4, 2,006.4 +/- 122.5, 929.3 +/- 73.4, and 845.1 +/- 72.5 mL, respectively. The volume difference between PTVint and PTVsep was significant (p < 0.001). All the PTVs ensured an average coverage larger than 99%, and the differences between any two PTVs were insignificant. This study proposed a novel personalized anisotropic margin search algorithm for cervical cancer online ART. Compared to the conventional 5 or 10 mm isotropic margins, the personalized anisotropic margin reduced PTV volume by 13.5% and 38.8%, respectively; if the uterus was considered separately, the volume can be further reduced by 21.3% and 44.3%, respectively, while CTV coverage was still maintained. This algorithm could reduce target volume and potentially spare normal tissue better than isotropic margin expansion.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy
    Liang, Xiao
    Chen, Liyuan
    Dan Nguyen
    Zhou, Zhiguo
    Gu, Xuejun
    Yang, Ming
    Wang, Jing
    Jiang, Steve
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [32] Middle meningeal artery embolization using cone-beam computed tomography augmented guidance in patients with cancer
    Dzaye, Omar
    Brahmbhatt, Akshaar
    Abajian, Aaron
    Moussa, Amgad M.
    Yu, Kenny K. H.
    Moss, Nelson S.
    Newman, William C.
    Lis, Eric
    Tabar, Viviane
    Cornelis, Francois H.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (7-8) : 368 - 372
  • [33] Pelvic target volume inter-fractional motion during radiotherapy for cervical cancer with daily iterative cone beam computed tomography
    Zeng, Zheng
    Zhu, Jiawei
    Wang, Zhiqun
    Wang, Guangyu
    Yan, Junfang
    Zhang, Fuquan
    RADIATION ONCOLOGY, 2024, 19 (01)
  • [34] Daily cone-beam computed tomography used to determine tumour shrinkage and localisation in lung cancer patients
    Knap, Marianne Marquard
    Hoffmann, Lone
    Nordsmark, Marianne
    Vestergaard, Anne
    ACTA ONCOLOGICA, 2010, 49 (07) : 1077 - 1084
  • [35] Perspectives of Cone-beam Computed Tomography in Interventional Radiology: Techniques for Planning, Guidance, and Monitoring
    Barral, Matthias
    Chevallier, Olivier
    Cornelis, Francois H.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 26 (03)
  • [36] Cone-beam computed tomography guidance with navigational overlay for percutaneous lung nodule biopsy
    Shivaram, Giridhar M.
    Gill, Anne Elizabeth
    Monroe, Eric J.
    Koo, Kevin S. H.
    Hawkins, C. Matthew
    PEDIATRIC RADIOLOGY, 2019, 49 (03) : 327 - 331
  • [37] Suppression of Cone-Beam Artefacts with Direct Iterative Reconstruction Computed Tomography Trajectories (DIRECTT)
    Magkos, Sotirios
    Kupsch, Andreas
    Bruno, Giovanni
    JOURNAL OF IMAGING, 2021, 7 (08)
  • [38] Cone-beam computed tomography guidance with navigational overlay for percutaneous lung nodule biopsy
    Giridhar M. Shivaram
    Anne Elizabeth Gill
    Eric J. Monroe
    Kevin S. H. Koo
    C. Matthew Hawkins
    Pediatric Radiology, 2019, 49 : 327 - 331
  • [39] Cone-beam computed tomography in lung stereotactic ablative radiation therapy: predictive parameters of early response
    Mazzola, Rosario
    Fiorentino, Alba
    Ricchetti, Francesco
    Levra, Niccolo Giaj
    Fersino, Sergio
    Di Paola, Gioacchino
    Lo Casto, Antonio
    Ruggieri, Ruggero
    Alongi, Filippo
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1064):
  • [40] Applications of linac-mounted kilovoltage Cone-beam Computed Tomography in modern radiation therapy: A review
    Srinivasan, Kavitha
    Mohammadi, Mohammad
    Shepherd, Justin
    POLISH JOURNAL OF RADIOLOGY, 2014, 79 : 181 - 193