A Personalized Anisotropic Margin for Cervical Cancer Radiation Therapy Under the Guidance of Daily Iterative Cone-Beam Computed Tomography (iCBCT)

被引:0
|
作者
Xiao, Haonan [1 ,2 ]
Guo, Qiufen [3 ]
Ma, Junjie [1 ]
Chen, Jian [4 ]
Xie, Peng [3 ]
Yin, Yong [1 ]
机构
[1] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp & Inst, Dept Radiat Oncol & Phys, Jinan, Peoples R China
[2] Shandong Canc Hosp, Shandong Prov Key Med & Hlth Lab Pediat Canc Preci, Dept Radiat Oncol & Phys, Jinan, Peoples R China
[3] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp & Inst, Dept Radiat Oncol, Jinan, Peoples R China
[4] Univ South China, Sch Nucl Sci & Technol, Dept Nucl Sci & Technol, Hengyang, Peoples R China
关键词
intrafraction motion; varian ethos; motion management; online art; cervical cancer; PELVIC ORGAN MOTION; TARGET VOLUME; RADIOTHERAPY; IMPACT;
D O I
10.7759/cureus.69029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Online adaptive radiation therapy (ART) eliminates interfraction uncertainties by adaption before each treatment session. However, intrafraction motions still exist and could become more severe due to long treatment time. Large isotropic margins can ensure clinical target volume (CTV) coverage but at the cost of more organs at risk damage. In this study, we proposed a novel personalized anisotropic margin search algorithm for cervical cancer radiation therapy under the guidance of daily iterative cone-beam computed tomography (iCBCT) to find the optimal margin values for each patient, which achieves the smallest possible planning target volume (PTV) and maintains CTV coverage. Twenty-two online Ethos ART treatment sessions were included for analysis. Two iCBCT scans were taken in each session. The first one (iCBCT(1)) was taken after positioning, and the second one (iCBCT(2)) was taken before beam delivery. Corresponding CTV1 and CTV(2 )were contoured in the two scans. In each session, minimal isotropic margins were first searched by iteratively increasing the magnitude until the resulting PTViso covers 99% of CTV2. Afterward, the margin values in all six directions were decreased iteratively until CTV2 coverage was smaller than 99% to get the personalized margin and target volume PTVint. In addition, the uterus was considered separately, and different margins were found for it and the remaining CTV, respectively, to reduce the target volume of PTV(sep )further. PTViso, PTVint, and PTVsep were compared in terms of CTV2 coverage and absolute volume. The algorithm successfully generated PTViso, PTVint, and PTVsep for all online ART treatment sessions. The mean +/- SD values for PTViso5mm, PTViso10mm, PTViso15mm, PTVint, and PTVsep were 1,074.0 +/- 78.1, 1,519.5 +/- 100.4, 2,006.4 +/- 122.5, 929.3 +/- 73.4, and 845.1 +/- 72.5 mL, respectively. The volume difference between PTVint and PTVsep was significant (p < 0.001). All the PTVs ensured an average coverage larger than 99%, and the differences between any two PTVs were insignificant. This study proposed a novel personalized anisotropic margin search algorithm for cervical cancer online ART. Compared to the conventional 5 or 10 mm isotropic margins, the personalized anisotropic margin reduced PTV volume by 13.5% and 38.8%, respectively; if the uterus was considered separately, the volume can be further reduced by 21.3% and 44.3%, respectively, while CTV coverage was still maintained. This algorithm could reduce target volume and potentially spare normal tissue better than isotropic margin expansion.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Image Guidance During Head-and-Neck Cancer Radiation Therapy: Analysis of Alignment Trends With In-Room Cone-Beam Computed Tomography Scans
    Zumsteg, Zachary
    DeMarco, John
    Lee, Steve P.
    Steinberg, Michael L.
    Lin, Chun Shu
    McBride, William
    Lin, Kevin
    Wang, Pin-Chieh
    Kupelian, Patrick
    Lee, Percy
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : 712 - 719
  • [22] Megavoltage and Kilovoltage Cone-Beam Computed Tomography Image Guidance for Lung Radiotherapy
    Vlad, M.
    Sixel, K.
    Kosowan, S.
    Hart, M.
    Iqbal, F.
    El-Mallah, M.
    Vandermeer, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [23] A Correction Algorithm for Kilovoltage Cone-Beam Computed Tomography Dose Calculations in Cervical Cancer Patients
    Zhang, J.
    Zhang, W.
    Lu, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3242 - 3242
  • [24] Implementing cone-beam computed tomography-guided online adaptive radiotherapy in cervical cancer
    Shelley, Charlotte E.
    Bolt, Matthew A.
    Hollingdale, Rachel
    Chadwick, Susan J.
    Barnard, Andrew P.
    Rashid, Miriam
    Reinlo, Selina C.
    Fazel, Nawda
    Thorpe, Charlotte R.
    Stewart, Alexandra J.
    South, Chris P.
    Adams, Elizabeth J.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 40
  • [25] DAILY IMAGE GUIDANCE WITH CONE-BEAM COMPUTED TOMOGRAPHY FOR HEAD-AND-NECK CANCER INTENSITY-MODULATED RADIOTHERAPY: A PROSPECTIVE STUDY
    Den, Robert B.
    Doemer, Anthony
    Kubicek, Greg
    Bednarz, Greg
    Galvin, James M.
    Keane, William M.
    Xiao, Ying
    Machtay, Mitchell
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1353 - 1359
  • [26] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [27] Patient radiation dose and protection from cone-beam computed tomography
    Li, Gang
    IMAGING SCIENCE IN DENTISTRY, 2013, 43 (02) : 63 - 69
  • [28] Cone-beam computed tomography (CBCT) for adaptive image guided head and neck radiation therapy
    Hvid, Christian A.
    Elstrom, Ulrik V.
    Jensen, Kenneth
    Grau, Cai
    ACTA ONCOLOGICA, 2018, 57 (04) : 552 - 556
  • [29] Comparison of different registration methods in cone-beam computed tomography for breast boost radiation therapy
    Lastrucci, A.
    Fedeli, L.
    Marciello, L.
    Serventi, E.
    Segnini, S.
    Meucci, F.
    Bernardi, L.
    Ricci, R.
    Marzano, S.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [30] Planning Target Volume Margin Suitability in Lung Stereotactic Body Radiation Therapy: A Preliminary Evaluation using Cone-beam Computed Tomography
    Mathew, L.
    Swaminath, A.
    Szabo, J.
    Wierzbicki, M.
    MEDICAL PHYSICS, 2012, 39 (07) : 4620 - 4620