Freshness in Salmon by Hand-Held Devices: Methods in Feature Selection and Data Fusion for Spectroscopy

被引:1
|
作者
Hardy, Mike [1 ,2 ]
Zadeh, Hossein Kashani [3 ,4 ]
Tzouchas, Angelis [3 ]
Vasefi, Fartash [3 ]
MacKinnon, Nicholas [3 ]
Bearman, Gregory [3 ]
Sokolov, Yaroslav [3 ]
Haughey, Simon A. [1 ]
Elliott, Christopher T. [1 ]
机构
[1] Queens Univ Belfast, Inst Global Food Secur, Ctr Excellence Agr & Food Integr, Sch Biol Sci,Natl Measurement Lab, Belfast BT9 5DL, North Ireland
[2] Queens Univ Belfast, Ctr Quantum Mat & Technol, Sch Math & Phys, Smart Nano NI, Belfast BT7 1NN, North Ireland
[3] SafetySpect Inc, Grand Forks, ND 58202 USA
[4] Univ North Dakota, Biomed Engn Program, Grand Forks, ND 58202 USA
来源
ACS FOOD SCIENCE & TECHNOLOGY | 2024年 / 4卷 / 12期
基金
美国海洋和大气管理局; “创新英国”项目;
关键词
fish freshness; food security; machine learning; data fusion; handheld spectroscopy; ENHANCED RAMAN-SPECTROSCOPY; FLUORESCENCE SPECTROSCOPY; QUANTITATIVE SERS; FROZEN FISH; FOOD; QUALITY; CHEMOMETRICS; TOOL;
D O I
10.1021/acsfoodscitech.4c00331
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Salmon fillet was analyzed via hand-held optical devices: fluorescence (@340 nm) and absorption spectroscopy across the visible and near-infrared (NIR) range (400-1900 nm). Spectroscopic measurements were benchmarked with nucleotide assays and potentiometry in an exploratory set of experiments over 11 days, with changes to spectral profiles noted. A second enlarged spectroscopic data set, over a 17 day period, was then acquired, and fillet freshness was classified +/- 1 day via four machine learning (ML) algorithms: linear discriminant analysis, Gaussian naive, weighted K-nearest neighbors, and an ensemble bagged tree method. Dual-mode data fusion returned almost perfect accuracies (mean = 99.5 +/- 0.51%), while single-mode ML analyses (fluorescence, visible absorbance, and NIR absorbance) returned lower mean accuracies at greater spread (77.1 +/- 10.1%). Single-mode fluorescence accuracy was especially poor; however, via principal component analysis, we found that a truncated fluorescence data set of four variables (wavelengths) could predict "fresh" and "spoilt" salmon fillet based on a subtle peak redshift as the fillet aged, albeit marginally short of statistical significance (95% confidence ellipse). Thus, whether by feature selection of one spectral data set, or the combination of multiple data sets through different modes, this study lays the foundation for better determination of fish freshness within the context of rapid spectroscopic analyses.
引用
收藏
页码:2813 / 2823
页数:11
相关论文
共 50 条
  • [31] HAND-HELD DATA INPUT DEVICE.
    Kennedy, P.J.
    IBM technical disclosure bulletin, 1984, 26 (11): : 5826 - 5827
  • [32] Hand-Held Optical Devices for Breast Cancer: Spectroscopy and 3-D Tomographic Imaging
    Erickson, Sarah J.
    Godavarty, Anuradha
    Martinez, Sergio L.
    Gonzalez, Jean
    Romero, Adrian
    Roman, Manuela
    Nunez, Annie
    Ge, Jiajia
    Regalado, Steven
    Kiszonas, Richard
    Lopez-Penalver, Cristina
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2012, 18 (04) : 1298 - 1312
  • [33] A System for Measuring Gaze Movement and Hand Movement Simultaneously for Hand-Held Devices
    Takahira, Hideaki
    Kikuchi, Kei
    Yamada, Mitsuho
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2015, E98B (01) : 51 - 61
  • [34] A novel Turbo decoder architecture for hand-held communication devices
    Kim, DH
    Kim, S
    Hwang, SY
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2002, 48 (02) : 202 - 208
  • [35] Feasibility of peach bloom thinning with hand-held mechanical devices
    Martin-Gorriz, B.
    Torregrosa, A.
    Brunton, J. Garcia
    SCIENTIA HORTICULTURAE, 2011, 129 (01) : 91 - 97
  • [36] Push model for information display on various hand-held devices
    Chuang, YD
    IC'03: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INTERNET COMPUTING, VOLS 1 AND 2, 2003, : 538 - 540
  • [37] Remote robot control using intelligent hand-held devices
    Wu, SD
    Chen, YM
    FOURTH INTERNATIONAL CONFERENCE ON COMPUTER AND INFORMATION TECHNOLOGY, PROCEEDINGS, 2004, : 587 - 592
  • [38] Measurement of nasal nitric oxide by hand-held and stationary devices
    Montella, Silvia
    Alving, Kjell
    Maniscalco, Mauro
    Sofia, Matteo
    De Stefano, Sara
    Raia, Valeria
    Santamaria, Francesca
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2011, 41 (10) : 1063 - 1070
  • [39] The true utility and indication for hand-held nerve conduction devices
    Ahmed, Aiesha
    Kothari, Milind J.
    MUSCLE & NERVE, 2012, 45 (05) : 621 - 622
  • [40] Effects of pen size on human performance on hand-held devices
    Ren, XS
    Ogasawara, M
    Kato, T
    PROCEEDINGS OF THE WORLD ENGINEERS' CONVENTION 2004, VOL A, NETWORK ENGINEERING AND INFORMATION SOCIETY, 2004, : 125 - 132