MRI in Patients with Cardiovascular Implantable Electronic Devices and Fractured or Abandoned Leads

被引:1
|
作者
Greenhill, Mark J. [1 ]
Rangan, Pooja [3 ]
Su, Wilber [5 ]
Weiss, J. Peter [5 ]
Zawaneh, Michael [5 ]
Unzek, Samuel [4 ,5 ]
Tamarappoo, Balaji [4 ,5 ]
Indik, Julia [2 ]
Tung, Roderick [5 ]
Morris, Michael F. [4 ,5 ]
机构
[1] Banner Univ, Med Ctr, Dept Radiol, Tucson, AZ USA
[2] Banner Univ, Med Ctr, Div Cardiol, Tucson, AZ USA
[3] Univ Arizona, Coll Med, Div Clin Data Analyt, Phoenix, AZ USA
[4] Banner Univ, Med Ctr, Dept Radiol, 1111 E McDowell Rd, Phoenix, AZ 85006 USA
[5] Banner Univ, Med Ctr, Div Cardiol, 1111 E McDowell Rd, Phoenix, AZ 85006 USA
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2024年 / 6卷 / 03期
关键词
PACEMAKER; SAFETY; IMPACT;
D O I
10.1148/ryct.230303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods: This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results: Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion: Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Radiotherapy for patients with cardiovascular implantable electronic devices: an 11-year experience
    Yeung, Cynthia
    Hazim, Bachar
    Campbell, Debra
    Gooding, Jim
    Li, Shirley X. L.
    Tam, Ho Kit
    Hopman, Wilma M.
    Chacko, Sanoj
    Redfearn, Damian P.
    Simpson, Christopher
    Abdollah, Hoshiar
    BaranchulJ, Adrian
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 55 (03) : 333 - 341
  • [42] Cardiovascular Implantable Electronic Device Leads in CKD and ESRD Patients: Review and Recommendations for Practice
    Saad, Theodore F.
    Hentschel, Dirk M.
    Koplan, Bruce
    Wasse, Haimanot
    Asif, Arif
    Patel, Daniel V.
    Salman, Loay
    Carrillo, Roger
    Hoggard, Jeff
    SEMINARS IN DIALYSIS, 2013, 26 (01) : 114 - 123
  • [43] Perspectives of patients with cardiovascular implantable electronic devices who received advisory warnings
    Ottenberg, Abigale L.
    Mueller, Luke A.
    Mueller, Paul S.
    HEART & LUNG, 2013, 42 (01): : 59 - 64
  • [44] Management of Cardiovascular Implantable Electronic Devices Infections in High-Risk Patients
    Kennergren, Charles
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2015, 4 (01) : 53 - 57
  • [45] Radiotherapy for patients with cardiovascular implantable electronic devices: an 11-year experience
    Cynthia Yeung
    Bachar Hazim
    Debra Campbell
    Jim Gooding
    Shirley XL Li
    Ho Kit Tam
    Wilma M. Hopman
    Sanoj Chacko
    Damian P. Redfearn
    Christopher Simpson
    Hoshiar Abdollah
    Adrian Baranchuk
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 333 - 341
  • [46] EFFICACY AND FEASIBILITY OF CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICES LEAD EXTRACTION IN ELDERLY PATIENTS
    Nagashima, Michio
    An, Yoshimori
    Ando, Kenji
    Soga, Yoshimitsu
    Nobuyoshi, Masakiyo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E709 - E709
  • [47] Efficacy and feasibility of cardiovascular implantable electronic devices lead extraction in elderly patients
    Nagashima, M.
    An, Y.
    Fukunaga, M.
    Hiroshima, K.
    Yamashita, K.
    Goya, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 375 - 375
  • [48] Are Contemporary Smartwatches and Mobile Phones Safe for Patients With Cardiovascular implantable Electronic Devices?
    Lacour, Philipp
    Parwani, Abdul Shokor
    Schuessler, Franziska
    Hohendanner, Felix
    Heinzel, Frank R.
    Trippel, Tobias D.
    Boldt, Leif-Hendrik
    Pieske, Burkert
    Blaschke, Florian
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (09) : 1158 - 1166
  • [49] Influence and safety of electronic apex locators in patients with cardiovascular implantable electronic devices: a systematic review
    AlRahabi, Mothanna K.
    Ghabbani, Hani M.
    LIBYAN JOURNAL OF MEDICINE, 2019, 14 (01)
  • [50] Monitoring Cardiovascular Implantable Electronic Devices (CIEDs) for Patients Receiving Radiotherapy (RT)
    Bowman, K.
    Popple, R.
    Doppalapudi, H.
    Fiveash, J. B.
    Meredith, R.
    Brezovich, I. A.
    Bonner, J. A.
    Spencer, S. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S599 - S599