MRI in Patients with Cardiovascular Implantable Electronic Devices and Fractured or Abandoned Leads

被引:1
|
作者
Greenhill, Mark J. [1 ]
Rangan, Pooja [3 ]
Su, Wilber [5 ]
Weiss, J. Peter [5 ]
Zawaneh, Michael [5 ]
Unzek, Samuel [4 ,5 ]
Tamarappoo, Balaji [4 ,5 ]
Indik, Julia [2 ]
Tung, Roderick [5 ]
Morris, Michael F. [4 ,5 ]
机构
[1] Banner Univ, Med Ctr, Dept Radiol, Tucson, AZ USA
[2] Banner Univ, Med Ctr, Div Cardiol, Tucson, AZ USA
[3] Univ Arizona, Coll Med, Div Clin Data Analyt, Phoenix, AZ USA
[4] Banner Univ, Med Ctr, Dept Radiol, 1111 E McDowell Rd, Phoenix, AZ 85006 USA
[5] Banner Univ, Med Ctr, Div Cardiol, 1111 E McDowell Rd, Phoenix, AZ 85006 USA
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2024年 / 6卷 / 03期
关键词
PACEMAKER; SAFETY; IMPACT;
D O I
10.1148/ryct.230303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods: This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results: Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion: Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Cardiovascular Implantable Electronic Devices in Athletes
    Do, Rose
    Patton, Kristen K.
    CARDIOVASCULAR THERAPEUTICS, 2010, 28 (05) : 327 - 336
  • [22] Infections of Cardiovascular Implantable Electronic Devices
    Baddour, Larry M.
    Cha, Yong-Mei
    Wilson, Walter R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (09): : 842 - 849
  • [23] Management of bacteremia in patients living with cardiovascular implantable electronic devices
    DeSimone, Daniel C.
    Sohail, M. Rizwan
    HEART RHYTHM, 2016, 13 (11) : 2247 - 2252
  • [24] Cardiovascular implantable electronic devices in hemodialysis patients: an updated review
    Spatola, Leonardo
    Rivera, Rodolfo F.
    Migliore, Federico
    Bilato, Claudio
    Mugnai, Giacomo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2021, 22 (12) : 867 - 873
  • [25] Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices and abandoned or epicardial leads: a systematic review and meta-analysis
    Meier, Claudia
    Israel, Carsten
    Eisenblaetter, Michel
    Hoyer, Annika
    Stoye, Ferdinand Valentin
    Yilmaz, Ali
    Gielen, Stephan
    EUROPACE, 2024, 26 (06):
  • [26] Leads dislodged into the pulmonary vascular bed in patients with cardiac implantable electronic devices
    Polewczyk, Maciej
    Jachec, Wojciech
    Polewczyk, Aneta M.
    Polewczyk, Anna
    Czajkowski, Marek
    Kutarski, Andrzej
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (04): : 348 - 354
  • [27] Advantages of Intra-cardiac Polymer Coated Electrodes Leads in Patients with Diabetes Mellitus and Cardiovascular Implantable Electronic Devices
    Pescariu, Silvius Alexandru
    Tudoran, Cristina
    Tudoran, Mariana
    Pop, Gheorghe Nicusor
    Pescariu, Sorin
    Timar, Romulus
    Andor, Bogdan
    MATERIALE PLASTICE, 2020, 57 (02) : 39 - 44
  • [28] Metal Artifact Reduction in Cardiovascular MRI for Accurate Myocardial Scar Assessment in Patients With Cardiac Implantable Electronic Devices
    Runge, Mason
    Ibrahim, El-Sayed H.
    Bogun, Frank
    Attili, Anil
    Mahani, Maryam Ghadimi
    Pang, Yuxi
    Horwood, Laura
    Chenevert, Thomas L.
    Stojanovska, Jadranka
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (03) : 555 - 561
  • [29] Predictors of pacing-dependency in patients with cardiovascular implantable electronic devices
    Grimm, Wolfram
    Grimm, Kathrin
    Greene, Brandon
    Parahuleva, Mariana
    CARDIOLOGY JOURNAL, 2021, 28 (03) : 423 - 430
  • [30] Power supplies for cardiovascular implantable electronic devices
    Deng, Jue
    Sun, Xuemei
    Peng, Huisheng
    ECOMAT, 2023, 5 (06)