Strength of titanium-zirconium alloy implants with a conical connection after implantoplasty

被引:2
|
作者
Shah, Sweety D. [1 ]
Zheng, Fengyuan [2 ]
Seghi, Robert R. [3 ]
Lee, Damian J. [1 ]
机构
[1] Ohio State Univ, Coll Dent, Adv Prosthodont Program, Div Restorat & Prosthet Dent, Columbus, OH USA
[2] Univ Minnesota, Sch Dent, Dept Restorat Sci, Adv Educ Prosthodont Program, Minneapolis, MN USA
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 03期
关键词
3-YEAR CLINICAL-TRIAL; SHAPED ORAL IMPLANTS; PERI-IMPLANTITIS; SURFACE-ROUGHNESS; MECHANICAL-PROPERTIES; RESECTIVE SURGERY; TACTILE FUNCTION; DENTAL IMPLANTS; IN-VIVO; THERAPY;
D O I
10.1016/j.prosdent.2022.08.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem.Peri-implantitis occurs around dental implants, and implantoplasty hasbeen used to address this ongoing disease; however, the changes to the physical properties ofan implant after implantoplasty have not been well documented. Purpose.The purpose of this in vitro study was to determine the effect of implantoplasty onfracture strength and the load required for plastic deformation after cyclic fatigue on dentalimplants. Material and methods.Twenty-six titanium/zirconium (TiZr) alloy implants (Roxolid Bone LevelImplant; 4.1x10 mm) were embedded with 50% thread exposure and divided into 4 groupsbased on whether they had implantoplasty treatment by using different diamond rotaryinstruments and/or cyclic loading at 250 N for 2 million cycles: C0 (control, no cyclic loading), T0(test, no cyclic loading), CM (control, cyclic loading), and TM (test, cyclic loading). Afterimplantoplasty and/or cyclic loading, all implants underwent a load-to-failure test. The maximumfracture strength (FS) and load required for the onset of plastic deformation (PD) were recordedin Newtons. One-way ANOVA and nonparametric comparisons with control by using the Dunnand Wilcoxon method for joint ranking were used for statistical analysis. Results.The mean +/- standard deviation FS for C0, CM, T0, and TM was 1465.2 +/- 86.4 N, 1480.7 +/- 64.1N, 1299.3 +/- 123.8 N, and 1252.1 +/- 85.7 N, respectively. The mean +/- standard deviation load for onsetof PD for C0, CM, T0, and TM was 860.2 +/- 88.1 N, 797.0 +/- 130.5 N, 776.5 +/- 181.8 N, and 631.3 +/- 84.5 N,respectively. The TM group had a significantly lower FS and PD than the C0, CM, and T0 groups(P<.05) Conclusions.Both fracture strength (FS) and the onset of plastic deformation (PD) weresignificantly reduced after a TiZr alloy implant received implantoplasty and cyclic loading. (JProsthet Dent 2024;132:593-9)
引用
收藏
页码:593 / 599
页数:7
相关论文
共 50 条
  • [41] Rehabilitation of an edentulous atrophic maxilla with four unsplinted narrow diameter titanium-zirconium implants supporting an overdenture
    Cordaro, Luca
    Torsello, Ferruccio
    di Torresanto, Vincenzo Mirisola
    Baricevic, Marinka
    QUINTESSENCE INTERNATIONAL, 2013, 44 (01): : 37 - 43
  • [42] Open magnetic resonance imaging using titanium-zirconium needles: Improved accuracy for interstitial brachytherapy implants?
    Popowski, Y
    Hiltbrand, E
    Joliat, D
    Ing, D
    Rouzaud, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (03): : 759 - 765
  • [43] Is titanium-zirconium alloy a better alternative to pure titanium for oral implant? Composition, mechanical properties, and microstructure analysis
    Sharma, Ajay
    Waddell, John N.
    Li, Kai C.
    Sharma, Lavanya A.
    Prior, David J.
    Duncan, Warwick J.
    SAUDI DENTAL JOURNAL, 2020, 33 (07) : 546 - 553
  • [44] Chemically modified titanium-zirconium implants in comparison with commercially pure titanium controls stimulate the early molecular pathways of bone healing
    Galli, Silvia
    Jimbo, Ryo
    Naito, Yoshihito
    Berner, Simon
    Dard, Michel
    Wennerberg, Ann
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (10) : 1234 - 1240
  • [45] An In Vitro Biomechanical Evaluation of a New Commercial Titanium-Zirconium Alloy Dental Implant: A Pilot Study
    Wu, Aaron Yu-Jen
    Hsu, Jui-Ting
    Huang, Heng-Li
    IMPLANT DENTISTRY, 2014, 23 (05) : 534 - 538
  • [46] Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid®) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients
    Chiapasco, M.
    Casentini, P.
    Zaniboni, M.
    Corsi, E.
    Anello, T.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1136 - 1141
  • [47] Effect of cerium nitrate and salicylic acid on the titanium-zirconium chemical conversion coating of 6061 aluminum alloy
    Wang, Xiaobo
    Zhan, Wen
    Gui, Boyi
    ANTI-CORROSION METHODS AND MATERIALS, 2020, 67 (02) : 205 - 213
  • [48] Analysis of Implant Strength After Implantoplasty in Three Implant-Abutment Connection Designs: An In Vitro Study
    Alexandre Gehrke, Sergio
    Aramburu Junior, Jaime Sarda
    Dedavid, Berenice Anina
    Shibli, Jamil Awad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : E65 - E70
  • [49] Maxillary and mandibular overdentures retained by two unsplinted narrow-diameter titanium-zirconium implants - A clinical pilot study
    Kern, Jaana-Sophia
    Salin, Esra
    Elvers, Dirk
    Rittich, Anne
    Tuna, Taskin
    Hoelzle, Frank
    Wolfart, Stefan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (09) : 1138 - 1150
  • [50] Survival of Titanium-Zirconium and Titanium Dental Implants in Cigarette-smokers and Never-smokers: A 5-Year Follow-up
    Alsahhaf, Abdulaziz
    Alshagroud, Rana Saud
    Al-Aali, Khulud Abdulrahman
    Alofi, Raneem S.
    Vohra, Fahim
    Abduljabbar, Tariq
    CHINESE JOURNAL OF DENTAL RESEARCH, 2019, 22 (04): : 265 - 272