Optimization of functional performance of additively manufactured cobalt-chromium-molybdenum alloy for dental implant applications

被引:2
|
作者
Nyakundi, A. M. [1 ]
Maina, M. R. [1 ]
Prasad, R. V. S. [2 ,4 ,5 ]
Olakanmi, E. O. [3 ,4 ,5 ]
Pityana, Sisa [6 ]
机构
[1] Jomo Kenyatta Univ Agr & Technol, Dept Mechatron Engn, Juja, Kenya
[2] Botswana Int Univ Sci & Technol, Dept Chem Mat & Met Engn, Palapye, Botswana
[3] Botswana Int Univ Sci & Technol, Dept Mech Energy & Ind Engn, Palapye, Botswana
[4] Botswana Int Univ Sci & Technol, Adv Mfg & Engn Educ AMEE Res Grp, Palapye, Botswana
[5] Botswana Int Univ Sci & Technol, UNESCO Chair Sustainable Mfg & Innovat Technol UCo, Palapye, Botswana
[6] CSIR, Natl Laser Ctr, Pretoria, South Africa
关键词
Laser engineered net shaping; Mechanical properties; Response surface methodology; Microstructure; Cobalt-chromium-molybdenum alloy; Dental implants; RESPONSE-SURFACE METHODOLOGY; PROCESSING PARAMETERS; MECHANICAL-PROPERTIES; SCANNING SPEED; HEAT-TREATMENT; LASER; STRENGTH; MICROSTRUCTURE; DEPOSITION; ROUGHNESS;
D O I
10.1016/j.jmapro.2024.05.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Improper selection of Laser Engineered Net Shaping (LENS) process parameters for the fabrication of cobalt-chromium-molybdenum (CoCrMo) alloy may result in poor quality components for dental implant applications. To solve the LENS fabrication challenge, this work utilizes response surface methodology (RSM) to investigate the influence of LENS deposition variables on the microstructural and mechanical performance of the manufactured samples for dental implant applications. Analysis of statistical data demonstrated that microhardness and porosity were both significantly influenced by laser scan speed and powder feed rate, while surface roughness is impacted substantially by laser scan speed and laser power. The analysis of the responses revealed that the optimum factors were at a scan speed of 5.3 mms(-1), powder feed rate of 4.748 gmin(-1) and laser power of 386.896 W to give surface roughness, porosity, and microhardness responses of 8.7775 mu m, 0.06 %, and 387.4286 HV, respectively. The models revealed a strong interaction between the actual experimental data and RSM-predicted responses. The results of this research can serve as a guide for determining suitable LENS input factors for the manufacture of dental implants.
引用
收藏
页码:1087 / 1103
页数:17
相关论文
共 49 条
  • [31] THE EFFECT OF A COMPOSITE CHITOSAN-SILVER(I) ION COATING ON THE CORROSION RESISTANCE OF THE COBALT-CHROMIUM-MOLYBDENUM ALLOY IN SALINE SOLUTION
    Losiewicz, Bozena
    Osak, Patrycja
    Kubisztal, Julian
    PROGRESS ON CHEMISTRY AND APPLICATION OF CHITIN AND ITS DERIVATIVES, 2023, 28 : 75 - 88
  • [32] Chemical composition, surface roughness, and ceramic bond strength of additively manufactured cobalt-chromium dental alloys
    Revilla-Leon, Marta
    Husain, Nadin Al-Haj
    Methani, Mohammed Mujtaba
    Ozcan, Mutlu
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (05): : 825 - 831
  • [33] Three cases of dental technician's pneumoconiosis related to cobalt-chromium-molybdenum dust exposure - Diagnosis and follow-up
    Selden, A
    Sahle, W
    Johansson, L
    Sorenson, S
    Persson, B
    CHEST, 1996, 109 (03) : 837 - 842
  • [34] Tribocorrosion behaviour of additively manufactured 0-type Ti-Nb alloy for implant applications
    Akman, Adnan
    Douest, Yohan
    Alberta, Ludovico Andrea
    Perrin, Kevin
    Sfarghiu, Ana -Maria Trunfio
    Courtois, Nicolas
    Ter-Ovanessian, Benoit
    Pilz, Stefan
    Zimmermann, Martina
    Calin, Mariana
    Gebert, Annett
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2024, 31 : 1419 - 1429
  • [35] Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release
    Summer, Burkhard
    Fink, Ulrich
    Zeller, Richard
    Rueff, Franziska
    Maier, Sonja
    Roider, Gabriele
    Thomas, Peter
    CONTACT DERMATITIS, 2007, 57 (01) : 35 - 39
  • [36] Cobalt-chromium-molybdenum but not titanium-6aluminium-4vanadium alloy discs inhibit human T cell activation in vitro
    Faleiro, C
    Godinho, I
    Reus, U
    deSousa, M
    BIOMETALS, 1996, 9 (04) : 321 - 326
  • [37] The effect of nitrogen alloying on stellite 21 cobalt chromium molybdenum biomedical implant alloy: processing and microstructure
    Karlsen, W
    HIGH NITROGEN STEELS '98, 1999, 318-3 : 303 - 308
  • [38] Atomic surface of cobalt-chromium-molybdenum alloy induced by novel green chemical mechanical polishing through controlling pH values and oxidation processes
    Liu, Haoran
    Zhang, Zhenyu
    Deng, Xingqiao
    Yu, Jiaxin
    Shi, Chunjing
    Zhou, Hongxiu
    Meng, Fanning
    Feng, Junyuan
    APPLIED SURFACE SCIENCE, 2024, 652
  • [39] Investigation on the Corrosion Resistance Properties of Cobalt-Chromium-Molybdenum Alloy Artificial Human Body Components with Robust Biomimetic Superhydrophobic and Slippery Surfaces Based on Laser Texturing
    Zhang, Li
    Tan, Zheng
    Wu, Tianci
    Zhang, Lulin
    Hao, Bo
    LANGMUIR, 2023, 39 (42) : 14996 - 15013
  • [40] Electrochemical Evaluation of Wrought Titanium -15 Molybdenum Alloy for Dental Implant Applications in Phosphate Buffer Saline
    Bhola, Rahul
    Bhola, Shaily M.
    Mishra, Brajendra
    Olson, David L.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2010, 28 (02) : 135 - 142