Optimization of functional performance of additively manufactured cobalt-chromium-molybdenum alloy for dental implant applications

被引:2
|
作者
Nyakundi, A. M. [1 ]
Maina, M. R. [1 ]
Prasad, R. V. S. [2 ,4 ,5 ]
Olakanmi, E. O. [3 ,4 ,5 ]
Pityana, Sisa [6 ]
机构
[1] Jomo Kenyatta Univ Agr & Technol, Dept Mechatron Engn, Juja, Kenya
[2] Botswana Int Univ Sci & Technol, Dept Chem Mat & Met Engn, Palapye, Botswana
[3] Botswana Int Univ Sci & Technol, Dept Mech Energy & Ind Engn, Palapye, Botswana
[4] Botswana Int Univ Sci & Technol, Adv Mfg & Engn Educ AMEE Res Grp, Palapye, Botswana
[5] Botswana Int Univ Sci & Technol, UNESCO Chair Sustainable Mfg & Innovat Technol UCo, Palapye, Botswana
[6] CSIR, Natl Laser Ctr, Pretoria, South Africa
关键词
Laser engineered net shaping; Mechanical properties; Response surface methodology; Microstructure; Cobalt-chromium-molybdenum alloy; Dental implants; RESPONSE-SURFACE METHODOLOGY; PROCESSING PARAMETERS; MECHANICAL-PROPERTIES; SCANNING SPEED; HEAT-TREATMENT; LASER; STRENGTH; MICROSTRUCTURE; DEPOSITION; ROUGHNESS;
D O I
10.1016/j.jmapro.2024.05.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Improper selection of Laser Engineered Net Shaping (LENS) process parameters for the fabrication of cobalt-chromium-molybdenum (CoCrMo) alloy may result in poor quality components for dental implant applications. To solve the LENS fabrication challenge, this work utilizes response surface methodology (RSM) to investigate the influence of LENS deposition variables on the microstructural and mechanical performance of the manufactured samples for dental implant applications. Analysis of statistical data demonstrated that microhardness and porosity were both significantly influenced by laser scan speed and powder feed rate, while surface roughness is impacted substantially by laser scan speed and laser power. The analysis of the responses revealed that the optimum factors were at a scan speed of 5.3 mms(-1), powder feed rate of 4.748 gmin(-1) and laser power of 386.896 W to give surface roughness, porosity, and microhardness responses of 8.7775 mu m, 0.06 %, and 387.4286 HV, respectively. The models revealed a strong interaction between the actual experimental data and RSM-predicted responses. The results of this research can serve as a guide for determining suitable LENS input factors for the manufacture of dental implants.
引用
收藏
页码:1087 / 1103
页数:17
相关论文
共 49 条
  • [21] Deformation and retentive forces variations of the additively manufactured cobalt-chromium and titanium alloys dental clasps
    El-Tamimi, Kawkb M.
    Bayoumi, Dalia A.
    Alshenaiber, Rafif
    Aljulayfi, Ibrahim
    Ahmed, Mohamed M. Z.
    El-Sayed, Mohammed E.
    SAUDI DENTAL JOURNAL, 2024, 36 (06) : 947 - 953
  • [22] Wear at the implant-framework interface between titanium implant platform and the additively manufactured titanium and cobalt-chromium frameworks
    Revilla-Leon, Marta
    Barmak, Abdul B.
    Rubenstein, Jeffrey
    Ozcan, Mutlu
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (01): : 77 - 85
  • [23] Effect of Cobalt-Chromium-Molybdenum Implant Surface Modifications on Biofilm Development of S. aureus and S. epidermidis
    Paulitsch-Fuchs, Astrid H.
    Boedendorfer, Benjamin
    Wolrab, Lukas
    Eck, Nicole
    Dyer, Nigel P.
    Lohberger, Birgit
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [24] Influence of synovial fluid constituents on the wear of cobalt-chromium-molybdenum alloy for metal-on-metal joint prostheses
    Nakanishi, Y
    Murakami, T
    Higaki, H
    Miyagawa, H
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 1999, 42 (03): : 481 - 486
  • [25] Cobalt-chromium-molybdenum alloy causes metal accumulation and metallothionein up-regulation in rat liver and kidney
    Jakobsen, Stig S.
    Danscher, Gorm
    Stoltenberg, Meredin
    Larsen, Agnete
    Bruun, Jens M.
    Mygind, Tina
    Kemp, Kaare
    Soballe, Kjeld
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2007, 101 (06) : 441 - 446
  • [26] Investigation of Microstructural Characteristics of Cobalt Chromium Molybdenum Additively Manufactured Using Laser Directed Energy Deposition Technology
    Grabowski, Theresa
    Ara, Ismat
    Thorpe, Joncy
    Azarmi, Fardad
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2023, 54 (10): : 4065 - 4079
  • [27] Investigation of Microstructural Characteristics of Cobalt Chromium Molybdenum Additively Manufactured Using Laser Directed Energy Deposition Technology
    Theresa Grabowski
    Ismat Ara
    Joncy Thorpe
    Fardad Azarmi
    Metallurgical and Materials Transactions A, 2023, 54 : 4065 - 4079
  • [28] FUNCTIONAL PERFORMANCE TAILORING OF ADDITIVELY MANUFACTURED COMPONENTS VIA TOPOLOGY OPTIMIZATION
    Steuben, John C.
    Michopoulos, John G.
    Iliopoulos, Athanasios P.
    Birnbaum, Andrew J.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2017, VOL 1, 2017,
  • [29] Microstructural features of biomedical cobalt-chromium-molybdenum (CoCrMo) alloy from powder bed fusion to aging heat treatment
    Li, Haoqing
    Wang, Ming
    Lou, Dianjun
    Xia, Weilong
    Fang, Xiaoying
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2020, 45 : 146 - 156
  • [30] A COMPARISON OF CORROSION RESISTANCE OF COBALT-CHROMIUM-MOLYBDENUM METAL CERAMIC ALLOY FABRICATED WITH SELECTIVE LASER MELTING AND TRADITIONAL PROCESSING
    Zeng, Li
    Xiang, Nan
    Wei, Bin
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (05): : 1217 - 1224