Design and characterisation of a minibeam collimator utilising Monte Carlo simulation and a clinical linear accelerator

被引:0
|
作者
Carver, Antony [1 ]
Baker, Sam [2 ]
Dumbill, Andrew [1 ]
Horton, Steven [1 ]
Green, Stuart [1 ]
机构
[1] Univ Hosp Birmingham NHS Fdn Trust, Birmingham, England
[2] Royal Marsden NHS Fdn Trust, London, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 13期
关键词
minibeam radiotherapy; spatial fractionation; dosimetry; Monte Carlo simulation; RADIATION-THERAPY; BEARING RATS; RADIOTHERAPY; BEAM; CODE;
D O I
10.1088/1361-6560/ad4d52
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Spatially fractionated radiotherapy is showing promise as a treatment modality. Initial focus was on beams of photons at low energy produced from a synchrotron but more recently research has expanded to include applications in proton therapy. Interest in photon beams remains and this is the focus of this paper Approach. This study presents a 3D printed tungsten minibeam collimator intended to produce peak-to-valley dose ratios (PVDR) of between seven and ten with a 1 MV, bremsstrahlung generated, photon beam. The design of the collimator is motivated by a Monte Carlo study estimating the PVDR for different collimator designs at different energies. This collimator was characterised on a clinical linear accelerator (Elekta VersaHD) as well as an orthovoltage unit. Main results. The performance of the fabricated collimator was measured on Elekta VersaHD running in unflattened mode with a 6 MV beam. On the Elekta VersaHD units the PVDR was measured to be between approximately 1.5 and 2.0 at 3 cm deep. For measurements with the orthovoltage unit PVDRs of greater than 10 were observed at a depth of 4 cm. Significance. The results confirmed that the predictions from simulation could be reproduced on linear accelerators currently in clinical usage, producing PVDRs between 2-2.5. Using the model to predict PVDRs using 1 MV photon beams, the threshold considered to produce enhanced normal tissue dose tolerance ( > 7) was surpassed. This suggests the possibility of using such techniques with versions of existing Linac technology which have been modified to operate at low energy and high beam currents.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Robust design of a breast scintigraphy collimator using Monte Carlo simulation and response surface method
    Balta, S.
    Guvenis, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S165 - S165
  • [32] Optimization of Collimator Design in HiReSPECT II: a Monte Carlo Study
    Mirdoraghi, M.
    Fard, B. Teimourian
    Kochebina, O.
    Mahani, H.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S699 - S699
  • [33] A study on scattered particles from medical linear accelerator head using monte carlo simulation
    Katayose, T. (u5856601@gs.metro-hs.ac.jp), (KEK High Energy Accelerator Research Organization):
  • [34] Monte Carlo Simulation of XHA600D 6MV Linear Accelerator
    Dai, Y.
    Lin, H.
    Wu, B.
    Cai, J.
    Pei, X.
    Cao, R.
    Chen, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Radiation dose distribution around a mobile linear accelerator Mobetron using Monte Carlo simulation
    Garcia-Cases, F.
    Patino, G.
    Perez-Calatayud, J.
    Ballester, F.
    Granero, D.
    Vijande, J.
    2016 GLOBAL MEDICAL ENGINEERING PHYSICS EXCHANGES/PAN AMERICAN HEALTH CARE EXCHANGES (GMEPE/PAHCE), 2016,
  • [36] MONTE CARLO SIMULATION OF ELECTRON DOSE DISTRIBUTIONS PRODUCED BY THE ELEKTA SYNERGY TM LINEAR ACCELERATOR
    Nedaie, H. A.
    Mosleh Shirazi, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S475 - S475
  • [37] Monte Carlo Simulation Studies of Collimator Parameters for TARLA Bremsstrahlung Facility
    Kuluozturk, Z. N.
    Demir, N.
    Akkurt, I.
    ACTA PHYSICA POLONICA A, 2017, 132 (03) : 796 - 800
  • [38] A Monte Carlo Simulation Study of Optimization for Collimator in a Pixelated SPECT Camera
    Telikani, Zeinab
    Sadremomtaz, Alireza
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (01) : 163 - 170
  • [39] Monte Carlo simulation of the dynamic collimator in a pencil beam scanning system
    Almeida, I. P.
    Sure, M.
    Vilches-Freixas, G.
    Cooley, J.
    Zwart, T.
    Langenegger, A.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S985 - S986
  • [40] Suggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems
    Hariri, Sanaz
    Shahriari, Majid
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (03): : 173 - 185