Design and characterisation of a minibeam collimator utilising Monte Carlo simulation and a clinical linear accelerator

被引:0
|
作者
Carver, Antony [1 ]
Baker, Sam [2 ]
Dumbill, Andrew [1 ]
Horton, Steven [1 ]
Green, Stuart [1 ]
机构
[1] Univ Hosp Birmingham NHS Fdn Trust, Birmingham, England
[2] Royal Marsden NHS Fdn Trust, London, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 13期
关键词
minibeam radiotherapy; spatial fractionation; dosimetry; Monte Carlo simulation; RADIATION-THERAPY; BEARING RATS; RADIOTHERAPY; BEAM; CODE;
D O I
10.1088/1361-6560/ad4d52
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Spatially fractionated radiotherapy is showing promise as a treatment modality. Initial focus was on beams of photons at low energy produced from a synchrotron but more recently research has expanded to include applications in proton therapy. Interest in photon beams remains and this is the focus of this paper Approach. This study presents a 3D printed tungsten minibeam collimator intended to produce peak-to-valley dose ratios (PVDR) of between seven and ten with a 1 MV, bremsstrahlung generated, photon beam. The design of the collimator is motivated by a Monte Carlo study estimating the PVDR for different collimator designs at different energies. This collimator was characterised on a clinical linear accelerator (Elekta VersaHD) as well as an orthovoltage unit. Main results. The performance of the fabricated collimator was measured on Elekta VersaHD running in unflattened mode with a 6 MV beam. On the Elekta VersaHD units the PVDR was measured to be between approximately 1.5 and 2.0 at 3 cm deep. For measurements with the orthovoltage unit PVDRs of greater than 10 were observed at a depth of 4 cm. Significance. The results confirmed that the predictions from simulation could be reproduced on linear accelerators currently in clinical usage, producing PVDRs between 2-2.5. Using the model to predict PVDRs using 1 MV photon beams, the threshold considered to produce enhanced normal tissue dose tolerance ( > 7) was surpassed. This suggests the possibility of using such techniques with versions of existing Linac technology which have been modified to operate at low energy and high beam currents.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Dosimetric evaluation of a dedicated stereotactic linear accelerator using measurement and Monte Carlo simulation
    Heydarian, M.
    Asnaashari, K.
    Allahverdi, M.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2008, 35 (09) : 3943 - 3954
  • [22] Monte Carlo Simulation for Prostate SBRT Using Primo with Truebeam Stx Linear Accelerator
    Ferrari, J.
    Apaza, O.
    Chesta, M.
    Venencia, C. D.
    MEDICAL PHYSICS, 2024, 51 (10) : 7888 - 7889
  • [23] Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator
    Kyoung Won Jang
    Manwoo Lee
    Heuijin Lim
    Sang Koo Kang
    Sang Jin Lee
    Seung Heon Kim
    Dong Eun Lee
    Hee Chang Kim
    Dong Hyeok Jeong
    Journal of the Korean Physical Society, 2020, 76 : 588 - 591
  • [24] Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator
    Jang, Kyoung Won
    Lee, Manwoo
    Lim, Heuijin
    Kang, Sang Koo
    Lee, Sang Jin
    Kim, Seung Heon
    Lee, Dong Eun
    Kim, Hee Chang
    Jeong, Dong Hyeok
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (07) : 588 - 591
  • [25] Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation
    Kairn, T.
    Crowe, S. B.
    Poole, C. M.
    Fielding, A. L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (03) : 129 - 135
  • [26] Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation
    T. Kairn
    S. B. Crowe
    C. M. Poole
    A. L. Fielding
    Australasian Physics & Engineering Sciences in Medicine, 2009, 32 : 129 - 135
  • [27] Monte Carlo Simulation and Development of a Multileaf Collimator for Proton Therapy
    Ainsley, C.
    Scheuermann, R.
    Avery, S.
    Dolney, D.
    Maughan, R.
    McDonough, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [28] Monte Carlo Simulation and Collimator Optimization for Tomographic Gamma Scanning
    Zhang, Jinzhao
    Tuo, Xianguo
    Wang, Qibiao
    Leng, Yangchun
    Shi, Rui
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [29] Design of Diagnostic Multileaf Collimator Based On the Monte Carlo Simulation for Dose Reduction of Diagnostic Radiography
    Han, S.
    Ji, Y.
    Kim, K.
    Choi, S.
    Jung, H.
    Park, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3405 - 3405
  • [30] Geometric Calibration of a Linear Accelerator modeled with Monte Carlo
    Escobar-Corral, N.
    Bornemann, C.
    Lotze, S.
    Schmachtenberg, A.
    Stahl, A.
    Eble, M. J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 141 - 141