Analysis of the Impact of Crowbar and Chopper Protection on Low Voltage Ride Through of DFIG

被引:0
|
作者
Guo, Zhengshan [1 ]
Wang, Zengping [1 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing, Peoples R China
关键词
electric system; LVRT; parameter tuning; Crowbar; Chopper;
D O I
10.1109/AEEES61147.2024.10544528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the installed capacity of wind power increasing, higher requirements are placed on the low-voltage ride-through capability of wind generator connected to the grid. Based on the analysis of the current grid-connected principle of the wind generator, the operation of the douply-fed asynchronous wind generator under the condition of voltage drop is theoretically analyzed, and a scheme of Crowbar circuit and Chopper circuit is proposed to protect the rotor excitation power supply and the generator itself. The article conducts detailed transient process derivation and simulation verification on various influencing factors such as the option of the Crowbar circuit resistance, the impact of the specific input and output time on the transient process, and the automatic detection and switching of Chopper. The simulation results show that they are consistent with the theory. Simulation is performed in the DFIG model established by Matlab/Simulink to verify its effectiveness. The simulation results show that the combined effect of the two circuits can effectively limit the rotor loop current and DC bus voltage during voltage drops, ensuring the safety of each component of the system; it is also proved that this solution can realize the operation of AC-excited doubly-fed asynchronous wind turbine without disconnecting from the grid during faults, and can play a positive role in stabilizing the grid voltage.
引用
收藏
页码:812 / 821
页数:10
相关论文
共 50 条
  • [31] Low voltage ride through control of DFIG wind energy generation system
    College of Electric Power, South China University of Technology, Guangzhou 510640, China
    Taiyangneng Xuebao, 2009, 11 (1527-1534):
  • [32] Improved Control Strategy for DFIG Wind Turbines for Low Voltage Ride Through
    Wu, Zaijun
    Zhu, Chanxia
    Hu, Minqiang
    ENERGIES, 2013, 6 (03) : 1181 - 1197
  • [33] The research for control strategy of low voltage ride-through based on DFIG
    Shang, Siqing
    Li, Huan
    Fan, Lintao
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 1299 - 1303
  • [34] Application of UPFC to Improve the Low-Voltage-Ride-Through Capability of DFIG
    Alharbi, Yasser M.
    Abu-Siada, A.
    2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 665 - 668
  • [35] A Review of Low Voltage Ride Through in DFIG under Unbalanced Grid Faults
    Luo, Jia
    Zhao, Haoran
    Lu, Xiaochen
    Gao, Shuning
    Ma, Qiang
    Terzija, Vladimir
    2019 IEEE PES GTD GRAND INTERNATIONAL CONFERENCE AND EXPOSITION ASIA (GTD ASIA), 2019, : 723 - 728
  • [36] Low voltage ride through enhancement in DFIG based WECS by hybrid method
    Parameswari, Angala G.
    Sait, Habeebullah
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2022, 109 (11) : 1855 - 1879
  • [37] A New Method for DFIG Fault Ride Through Using Resistance and Capacity Crowbar Circuit
    Wang, Maoze
    Xu, Wei
    Jia, Hongjie
    Yu, Xinghuo
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2013, : 2004 - 2009
  • [38] Crowbar-less ride through of asymmetrical grid faults with DFIG based WECS
    Uphues, Andreas
    Noetzold, Kilian
    Wegener, Ralf
    Soter, Stefan
    2017 IEEE AFRICON, 2017, : 1026 - 1031
  • [39] Transient analysis and control strategy improvement of high voltage ride through of DFIG
    Sun L.-L.
    Wang Y.-J.
    Xu B.-Q.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2019, 23 (02): : 27 - 34
  • [40] A Low Voltage Ride Through Strategy of DFIG based on Explicit Model Predictive Control
    Luo, Jia
    Zhao, Haoran
    Gao, Shuning
    Han, Mingzhe
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 119