A parametric study regarding structural design of a bioprosthetic aortic valve by 3D fluid-structure interaction simulations

被引:0
|
作者
Kim, Yongwoo [1 ]
Pyo, Won Kyung [2 ]
Kim, Wan Kee [3 ]
Suh, Ga-Young [4 ]
Kang, Keonwook [1 ]
Lee, Seung Hyun [2 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
[2] Yonsei Univ, Severance Hosp, Coll Med, Dept Thorac Cardiovasc Surg, Seoul, South Korea
[3] Yonsei Univ, Yongin Severance Hosp, Coll Med, Dept Thorac & Cariovasc Surg, Yongin, Gyeonggi Do, South Korea
[4] Calif State Univ Long Beach, Dept Biomed Engn, Long Beach, CA 90840 USA
基金
新加坡国家研究基金会;
关键词
Aortic valve; Fluid-structure interaction; Hemodynamics; Biomechanics; MECHANICAL-PROPERTIES; BOVINE PERICARDIUM; SIZE; REPLACEMENT; COAPTATION; MODEL;
D O I
10.1016/j.heliyon.2024.e27310
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Since the introduction of transcatheter aortic valve (AV) implantation as a viable option, surgical bioprosthetic AVs have recently started incorporating shorter struts considering future valve -invalve procedures. However, the effect of leaflet coaptation geometry on the longevity of these valves remains unexplored. To address this gap, we performed a finite element analysis on bioprosthetic AVs with varying strut heights using a two-way fluid-structure interaction method. To establish a baseline, we used a standard height based on a rendered platform image of the CE PERIMOUNT Magna Ease valve from Edward Lifesciences in Irvine, CA. Bovine pericardium properties were assigned to the leaflets, while normal saline properties were used as the recirculating fluid in hemodynamic simulations. The physiological pressure profile of the cardiac cycle was applied between the aorta and left ventricle. We calculated blood flow velocity, effective orifice area (EOA), and mechanical stress on the leaflets. The results reveal that as the strut height increases, the stroke volume increases, leakage volume decreases, and EOA improves. Additionally, the maximum mechanical stress experienced by the leaflet decreases by 62% as the strut height increases to 1.2 times the standard height. This research highlights that a low-strut design in bioprosthetic AVs may negatively affect their durability, which can be useful in design of nextgeneration bioprosthetic AVs.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Fluid-structure interaction of a pulsatile flow with an aortic valve model: A combined experimental and numerical study
    Siguenza, Julien
    Pott, Desiree
    Mendez, Simon
    Sonntag, Simon J.
    Kaufmann, Tim A. S.
    Steinseifer, Ulrich
    Nicoud, Franck
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2018, 34 (04)
  • [42] The impact of the aortic valve impairment on the distant coronary arteries hemodynamics: a fluid-structure interaction study
    Mohammadi, Hossein
    Cartier, Raymond
    Mongrain, Rosaire
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (10) : 1859 - 1872
  • [43] A Fluid-Structure Interaction Study of Different Bicuspid Aortic Valve Phenotypes Throughout the Cardiac Cycle
    Yan, Wentao
    Li, Jianming
    Wang, Wenshuo
    Wei, Lai
    Wang, Shengzhang
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [44] Porcine and bovine aortic valve comparison for surgical optimization: A fluid-structure interaction modeling study
    Li, Caili
    Tang, Dalin
    Yao, Jing
    Shao, Yongfeng
    Sun, Haoliang
    Hammer, Peter
    Gong, Chanjuan
    Ma, Luyao
    Zhang, Yanjuan
    Wang, Liang
    Yu, Han
    Yang, Chun
    Baird, Christopher
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 334 : 88 - 95
  • [45] Simulation Study of Aortic Valve Function Using the Fluid-structure Interaction Finite Element Method
    Sugiura, Seiryo
    Katayama, Susumu
    Umetani, Nobuyuki
    Hisada, Toshiaki
    ADVANCES IN UNDERSTANDING AORTIC DISEASES, 2009, : 53 - 60
  • [46] Parametric study of a spherical head model in fluid-structure interaction
    El Baroudi, A.
    Razafimahery, F.
    Rakotomanana, L.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 : 241 - 242
  • [47] Fluid-Structure Interaction Analysis on the Influence of the Aortic Valve Stent Leaflet Structure in Hemodynamics
    Liu, Xiangkun
    Zhang, Wen
    Ye, Ping
    Luo, Qiyi
    Chang, Zhaohua
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [48] Multi-patient study for coronary vulnerable plaque model comparisons: 2D/3D and fluid-structure interaction simulations
    Wang, Qingyu
    Tang, Dalin
    Wang, Liang
    Meahara, Akiko
    Molony, David
    Samady, Habib
    Zheng, Jie
    Mintz, Gary S.
    Stone, Gregg W.
    Giddens, Don P.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (04) : 1383 - 1397
  • [49] Fluid-Structure Interaction methods for the progressive anatomical and artificial aortic valve stenosis
    Nowak, Marcin
    Divo, Eduardo
    Adamczyk, Wojciech P.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2022, 227
  • [50] Fluid-structure interaction modeling of aortic valve stenosis at different heart rates
    Bahraseman, Hamidreza Ghasemi
    Languri, Ehsan Mohseni
    Yahyapourjalaly, Niloofar
    Espino, Daniel M.
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2016, 18 (03) : 11 - 20