A parametric study regarding structural design of a bioprosthetic aortic valve by 3D fluid-structure interaction simulations

被引:0
|
作者
Kim, Yongwoo [1 ]
Pyo, Won Kyung [2 ]
Kim, Wan Kee [3 ]
Suh, Ga-Young [4 ]
Kang, Keonwook [1 ]
Lee, Seung Hyun [2 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
[2] Yonsei Univ, Severance Hosp, Coll Med, Dept Thorac Cardiovasc Surg, Seoul, South Korea
[3] Yonsei Univ, Yongin Severance Hosp, Coll Med, Dept Thorac & Cariovasc Surg, Yongin, Gyeonggi Do, South Korea
[4] Calif State Univ Long Beach, Dept Biomed Engn, Long Beach, CA 90840 USA
基金
新加坡国家研究基金会;
关键词
Aortic valve; Fluid-structure interaction; Hemodynamics; Biomechanics; MECHANICAL-PROPERTIES; BOVINE PERICARDIUM; SIZE; REPLACEMENT; COAPTATION; MODEL;
D O I
10.1016/j.heliyon.2024.e27310
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Since the introduction of transcatheter aortic valve (AV) implantation as a viable option, surgical bioprosthetic AVs have recently started incorporating shorter struts considering future valve -invalve procedures. However, the effect of leaflet coaptation geometry on the longevity of these valves remains unexplored. To address this gap, we performed a finite element analysis on bioprosthetic AVs with varying strut heights using a two-way fluid-structure interaction method. To establish a baseline, we used a standard height based on a rendered platform image of the CE PERIMOUNT Magna Ease valve from Edward Lifesciences in Irvine, CA. Bovine pericardium properties were assigned to the leaflets, while normal saline properties were used as the recirculating fluid in hemodynamic simulations. The physiological pressure profile of the cardiac cycle was applied between the aorta and left ventricle. We calculated blood flow velocity, effective orifice area (EOA), and mechanical stress on the leaflets. The results reveal that as the strut height increases, the stroke volume increases, leakage volume decreases, and EOA improves. Additionally, the maximum mechanical stress experienced by the leaflet decreases by 62% as the strut height increases to 1.2 times the standard height. This research highlights that a low-strut design in bioprosthetic AVs may negatively affect their durability, which can be useful in design of nextgeneration bioprosthetic AVs.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Validation and Extension of a Fluid-Structure Interaction Model of the Healthy Aortic Valve
    Tango, Anna Maria
    Salmonsmith, Jacob
    Ducci, Andrea
    Burriesci, Gaetano
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 739 - 751
  • [32] Fluid-structure interaction of deformable aortic prostheses with a bileaflet mechanical valve
    de Tullio, M. D.
    Afferrante, L.
    Demelio, G.
    Pascazio, G.
    Verzicco, R.
    JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1684 - 1690
  • [33] Numerical analysis of fluid-structure interaction with 3D models of ideal elastic abdominal aortic aneurysm
    Cong, Ying-Bo
    Wang, Li-Ya
    Liu, Xiao
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2013, 34 (SUPPL.2): : 275 - 278
  • [35] Comparison between the fluid-structure interaction approach and the finite element method approach to analyze the leaflet flutter in bioprosthetic aortic valve
    Costa, Matheus Carvalho Barbosa
    Gonsalves, Saulo de Freitas
    Fleury, Joao Victor Curado
    Silva, Mario Luis Ferreira da
    Huebner, Rudolf
    Avelar, Artur Henrique de Freitas
    JOURNAL OF BIOMECHANICS, 2025, 181
  • [36] Fluid-structure interaction simulations of patient-specific aortic dissection
    Baeumler, Kathrin
    Vedula, Vijay
    Sailer, Anna M.
    Seo, Jongmin
    Chiu, Peter
    Mistelbauer, Gabriel
    Chan, Frandics P.
    Fischbein, Michael P.
    Marsden, Alison L.
    Fleischmann, Dominik
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (05) : 1607 - 1628
  • [37] Existence of a weak solution to the fluid-structure interaction problem in 3D
    Trifunovic, Srdan
    Wang, Ya-Guang
    JOURNAL OF DIFFERENTIAL EQUATIONS, 2020, 268 (04) : 1495 - 1531
  • [38] 3D fluid-structure interaction with fracturing: A new method with applications
    Dalla Barba, Federico
    Zaccariotto, Mirco
    Galvanetto, Ugo
    Picano, Francesco
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2022, 398
  • [39] PATIENT-SPECIFIC VALVE DYNAMICS USING 3D FLUID-STRUCTURE INTERACTION MODELING: COMPARISON BETWEEN BICUSPID AND TRISCUSPID AORTIC VALVES
    Govindarajan, V.
    Mousel, J.
    Vigmostad, S. C.
    Udaykumar, H. S.
    Levack, M. M.
    Gorman, J. H., III
    Jackson, B. M.
    Gorman, R. C.
    Chandran, K. B.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [40] Fluid-Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics
    Mao, Wenbin
    Li, Kewei
    Sun, Wei
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2016, 7 (04) : 374 - 388