A comparison of the relative biological effectiveness of low energy electronic brachytherapy sources in breast tissue: a Monte Carlo study

被引:21
|
作者
White, Shane A. [1 ]
Reniers, Brigitte [1 ]
de Jong, Evelyn E. C. [1 ]
Rusch, Thomas [2 ]
Verhaegen, Frank [1 ,3 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiat Oncol MAASTRO, GROW Sch Oncol & Dev Biol, NL-6200 MD Maastricht, Netherlands
[2] Xoft, San Jose, CA USA
[3] McGill Univ, Dept Oncol, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 01期
关键词
relative biological effectiveness; low energy brachytherapy; electronic brachytherapy; Monte Carlo; INTRAOPERATIVE RADIOTHERAPY TARGIT; CLUSTERED DNA LESIONS; X-RAYS; DAMAGE; RBE; IRRADIATION; SIMULATION; INDUCTION; DOSIMETRY; OXYGEN;
D O I
10.1088/0031-9155/61/1/383
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electronic brachytherapy sources use low energy photons to treat the tumor bed during or after breast-conserving surgery. The relative biological effectiveness of two electronic brachytherapy sources was explored to determine if spectral differences due to source design influenced radiation quality and if radiation quality decreased with distance in the breast. The RBE was calculated through the number of DNA double strand breaks (RBEDSB) using the Monte Carlo damage simulator (MCDS) in combination with other Monte Carlo electron/photon spectrum calculations. 50kVp photons from the Intrabeam (Carl Zeiss Surgical) and Axxent (Xoft) through 40-mm spherical applicators were simulated to account for applicator and tissue attenuation in a variety of breast tissue compositions. 40kVp Axxent photons were also simulated. Secondary electrons (known to be responsible for most DNA damage) spectra at different distance were inputted into MCDS to calculate the RBEDSB. All RBEDSB used a cobalt-60 reference. RBEDSB data was combined with corresponding average photon spectrum energy for the Axxent and applied to model-based average photon energy distributions to produce an RBEDSB map of an accelerated partial breast irradiation (APBI) patient. Both Axxent and Intrabeam 50kVp spectra were shown to have a comparable RBEDSB of between 1.4 and 1.6 at all distances in spite of progressive beam hardening. The Axxent 40kVp also demonstrated a similar RBEDSB at distances. Most RBEDSB variability was dependent on the tissue type as was seen in rib (RBEDSB approximate to 1.4), gland (approximate to 1.55), adipose (approximate to 1.59), skin (approximate to 1.52) and lung (approximate to 1.50). RBEDSB variability between both sources was within 2%. A correlation was shown between RBEDSB and average photon energy and used to produce an RBEDSB map of a dose distribution in an APBI patient dataset. Radiation quality is very similar between electronic brachytherapy sources studied. No significant reductions in RBEDSB were observed with increasing distance from the source.
引用
收藏
页码:383 / 399
页数:17
相关论文
共 50 条
  • [31] Monte Carlo study of a novel electronic brachytherapy device: Radiation quality effects
    Reniers, B.
    Liu, D.
    Rusch, T.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S34 - S34
  • [32] Microdosimetry-based investigation of biological effectiveness of 252Cf brachytherapy source: TOPAS Monte Carlo study
    Chattaraj, Arghya
    Selvam, T. Palani
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (22):
  • [33] Estimating the relative biological effectiveness of light ions using TOPAS monte carlo simulation
    Efendi, M. Arif
    Sakata, D.
    Keat, Y. C.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (03):
  • [34] Dual energy CT tissue quantitation for Monte Carlo based treatment planning for brachytherapy
    Devic, S
    Monroe, JI
    Mutic, S
    Whiting, B
    Williamson, JF
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 364 - 367
  • [35] Comparison of organ doses for patients undergoing balloon brachytherapy of the breast with HDR 192Ir or electronic sources using Monte Carlo simulations in a heterogeneous human phantom
    Mille, Matthew M.
    Xu, X. George
    Rivard, Mark J.
    MEDICAL PHYSICS, 2010, 37 (02) : 662 - 671
  • [36] Monte Carlo calculation of the relative TG-43 dosimetry parameters for the INTRABEAM electronic brachytherapy source
    Alvarez, David Santiago Ayala
    Watson, Peter G. F.
    Popovic, Marija
    Heng, Veng Jean
    Evans, Michael D. C.
    Seuntjens, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [37] Secondary fragmentation and relative biological effectiveness (RBE) study using Bridge SOI microdosimeter: Monte Carlo simulation
    Ying, C. K.
    Arif Efendi, M.
    Guatelli, Susanna
    Tran, Linh T.
    Bolst, David
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [38] Impact of spherical applicator diameter on relative biologic effectiveness of low energy IORT X-rays: A hybrid Monte Carlo study
    Shamsabadi, Reza
    Baghani, Hamid Reza
    Azadegan, Behnam
    Mowlavi, Ali Asghar
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 297 - 307
  • [39] Influences of spherical phantom heterogeneities on dosimetric charactristics of miniature electronic brachytherapy X-ray sources: Monte Carlo study
    Jashni, Hojatollah Karimi
    Safigholi, Habib
    Meigooni, Ali S.
    APPLIED RADIATION AND ISOTOPES, 2015, 95 : 108 - 113
  • [40] Relation between depth dose and HVL for electronic brachytherapy systems: a Monte Carlo study
    Valdes, C.
    Ballester, F.
    Vijande, J.
    Perez-Calatayud, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S943 - S944