Testing of a Micro Hydro Power Plant Using a Cross-Flow Type Turbine

被引:0
|
作者
Suwasti, Sri [1 ]
Mulyadi, Musrady [1 ]
Klistafani, Yiyin [1 ]
Djalal, Muhammad Ruswandi [1 ]
机构
[1] State Poytech Ujung Pandang, Dept Mech Engn, Makassar, Indonesia
来源
PRZEGLAD ELEKTROTECHNICZNY | 2024年 / 100卷 / 06期
关键词
Testing; Micro Hydro Power Plant; Efficiency; Cross-flow Turbine;
D O I
10.15199/48.2024.06.51
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The implementation of Micro Hydro Power Plants (MHPP) serves as a crucial initiative to address the uneven distribution of electrical energy in remote areas across Indonesia. Before the permanent installation of an MHPP, field testing is imperative, involving the use of a model or prototype to gather location -specific data, assess reliability, and enhance insights into the MHPP's functionality as an electrical energy generator. This research endeavors to comprehend the operation of the Cross -flow turbine MHPP system and ascertain its output power and efficiency. The testing process commences with the design of field test equipment, followed by manufacturing and assembly stages. Subsequently, equipment testing and data collection are conducted, and the obtained data is analyzed to determine the output power and efficiency of the MHPP system utilizing a Cross -flow turbine. The test parameters include water flow, head, turbine input power, generator output power, and overall MHPP system efficiency. Upon analyzing the results and engaging in discussions, it can be concluded that the test considered crucial parameters such as water flow, head, turbine input power, generator output power, and MHPP system efficiency. The highest efficiency recorded was under variable load conditions with a fluctuating discharge of approximately 0.025 m(3) /s, achieving 1.39% efficiency at a load of 80 W. The research findings indicate that variations in head and discharge significantly impact the efficiency of the MHPP system.
引用
收藏
页码:244 / 247
页数:4
相关论文
共 50 条
  • [31] EXPERIMENTAL-STUDY OF CROSS-FLOW TURBINE
    KHOSROWPANAH, S
    FIUZAT, AA
    ALBERTSON, ML
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1988, 114 (03): : 299 - 314
  • [32] Implications of biofouling on cross-flow turbine performance
    Carl C. Stringer
    Brian L. Polagye
    SN Applied Sciences, 2020, 2
  • [33] STUDY ON HYDRODYNAMIC PERFORMANCE OF DARRIEUS-TYPE CROSS-FLOW WATER TURBINE
    TAKAMATSU, Y
    FURUKAWA, A
    OKUMA, K
    SHIMOGAMA, Y
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1985, 28 (240): : 1119 - 1127
  • [34] Study on the Flow Field of an Undershot Cross-flow Water Turbine
    Li, Yanrong
    Nishi, Yasuyuki
    Inagaki, Terumi
    Hatano, Kentarou
    INDUSTRIAL ENGINEERING AND APPLIED RESEARCH, 2014, 620 : 285 - +
  • [35] Running characteristics of a cross-flow water turbine in oscillating flow
    Fukutomi, J
    Nakase, Y
    PROCEEDINGS OF THE SIXTH (1996) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL I, 1996, 1996, : 75 - 81
  • [36] Modeling the Unsteady Cavitating Flow in a Cross-Flow Water Turbine
    Sansone, E.
    Pellone, C.
    Maitre, T.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (07): : 0713021 - 07130213
  • [37] Water intake flow efficiency study for micro-hydro power plant
    Pop, Radu
    Vaida, Liviu
    Bot, Adrian
    11TH INTERNATIONAL CONFERENCE OF PROCESSES IN ISOTOPES AND MOLECULES (PIM 2017), 2017, 1917
  • [38] Numerical Simulation-Based Effect Characterization and Design Optimization of a Micro Cross-Flow Turbine
    Woldemariam, Endashaw T.
    Lemu, Hirpa G.
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2019, 65 (06): : 386 - 397
  • [39] CFD-Driven Valve Shape Optimization for Performance Improvement of a Micro Cross-Flow Turbine
    Woldemariam, Endashaw Tesfaye
    Lemu, Hirpa G.
    Wang, G. Gary
    ENERGIES, 2018, 11 (01):
  • [40] A review on turbines for micro hydro power plant
    Jawahar, C. P.
    Michael, Prawin Angel
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 72 : 882 - 887