NaI:Tl; Inorganic scintillator; Codoping; Energy resolution; n/gamma discrimination;
D O I
10.1016/j.radmeas.2024.107232
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
NaI:Tl single crystals codoped with (LiI)-Li-6 have been considered as promising neutron-gamma scintillators due to low cost, scalability, and high efficiency in detecting and discriminating neutrons and gamma-rays. This study aims to study the effects of (LiF)-Li-6 and (LiCl)-Li-6 codoping on the NaI:Tl single crystals grown by the multi-ampoule Bridgman method. The impact of (LiF)-Li-6 and (LiCl)-Li-6 on the optical properties, gamma spectroscopy, and pulse shape discrimination (PSD) of neutron and gamma detection performance were analyzed. Both (LiF)-Li-6 and (LiCl)-Li-6 caused a decrease in gamma-ray light yield and a deterioratrion of energy resolution with increasing codoping concentrations, similar to the scenarios of (LiI)-Li-6 codoping. Nonetheless, for NaI:Tl,(LiF)-Li-6, the light yield and PSD Figure-of-Merit (FoM) are almost unchanged about 37,500 photons/MeV and 4.6 when the Li content reaches 2 at%, which is better than the scenario of (LiI)-Li-6 codoping. Combing with the advantages of non-hygroscopic nature of LiF and a higher utilization yield of Li element in LiF comparing with LiI, NaI:Tl,(LiF)-Li-6 single crystals could be regarded as more cost-effective scintillators for neutron detection applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Tl2ZrCl6 and Tl2HfCl6 Intrinsic Scintillators for Gamma Rays and Fast Neutron Detection
    Bhattacharya, Pijush
    Brown, Conner
    Sosa, Charles
    Wart, Megan
    Miller, Stuart
    Brecher, Charles
    Nagarkar, Vivek V.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (06) : 1032 - 1034
  • [12] ZnO:Zn/6LiF scintillator-A low afterglow alternative to ZnS:Ag/6LiF for thermal neutron detection3
    Sykora, G. Jeff
    Schooneveld, Erik M.
    Rhodes, Nigel J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 883 : 75 - 82
  • [13] Position-sensitive neutron detection with 6LiF layers on silicon semiconductors
    Inst fuer Schicht- und Ionentechnik, Juelich, Germany
    Nucl Instrum Methods Phys Res Sect A, 3 (447-453):
  • [14] Behaviour of 6LiF Covered Single Crystal Diamond Detectors Operated at High Temperature Under Neutron Irradiation
    Angelone, M.
    Pietropaolo, T.
    Pillon, M.
    Sarto, F.
    Lecci, S.
    Marinelli, Marco
    Milani, E.
    Pompili, F.
    Prestopino, G.
    Verona, C.
    Verona-Rinati, G.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [15] Neutron detection and identification using ZnS:Ag/6LiF in segmented antineutrino detectors
    Kiff, Scott D.
    Bowden, Nathaniel
    Lund, Jim
    Reyna, David
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 412 - 416
  • [16] Thermal neutron detection using a silicon pad detector and 6LiF removable converters
    Barbagallo, Massimo
    Cosentino, Luigi
    Forcina, Vittorio
    Marchetta, Carmelo
    Pappalardo, Alfio
    Peerani, Paolo
    Scire, Carlotta
    Scire, Sergio
    Schillaci, Maria
    Vaccaro, Stefano
    Vecchio, Gianfranco
    Finocchiaro, Paolo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (03):
  • [17] 6LiF Oleic Acid Capped Nanoparticles Entrapment in Siloxanes for Thermal Neutron Detection
    Carturan, S.
    Maggioni, G.
    Marchi, T.
    Gramegna, F.
    Cinausero, M.
    Quaranta, A.
    Palma, M. Dalla
    LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2016, 1753
  • [18] Fabrication and performance evaluation of GaN thermal neutron detectors with 6LiF conversion layer
    Zhu, Zhifu
    Sun, Zhijia
    Zou, Jijun
    Tang, Bin
    Xiu, Qinglei
    Wang, Renbo
    Qu, Jinhui
    Deng, Wenjuan
    Wang, Shaotang
    Peng, Junbo
    Wang, Zhidong
    Tang, Bin
    Zhang, Haiping
    CHINESE PHYSICS B, 2020, 29 (09)
  • [19] Fabrication and performance evaluation of GaN thermal neutron detectors with ~6LiF conversion layer
    朱志甫
    孙志嘉
    邹继军
    唐彬
    修青磊
    王仁波
    瞿金辉
    邓文娟
    王少堂
    彭俊波
    王志栋
    汤彬
    张海平
    Chinese Physics B, 2020, 29 (09) : 252 - 256
  • [20] Improvement of Energy Resolution and Neutron-Gamma Discrimination of NaI:Tl,6Li Single Crystal Scintillators by Ca2+ and Sr2+ Co-Doping
    Wang, Jingkang
    Wang, Chenger
    Li, Huanyin
    Shi, Jian
    Wen, Xuemin
    Shan, Chenyu
    Ren, Guohao
    Sun, Xilei
    Wu, Yuntao
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (05) : 840 - 846