Load-Level Isolation System for industrial racks: Evaluations on a case study structure

被引:0
|
作者
Bernardi, E. [1 ,2 ]
Dona, M. [1 ,2 ]
Zonta, A. [2 ]
Ceresara, M. [2 ]
Mozzon, S. [2 ]
da Porto, F. [2 ]
Tan, P. [3 ]
机构
[1] Guangzhou Univ, Earthquake Engn Res & Test Ctr, Guangzhou, Peoples R China
[2] Univ Padua, Dept Geosci, Padua, Italy
[3] Guangzhou Univ, Sch Civil Engn, Guangzhou, Peoples R China
关键词
COLUMN JOINTS;
D O I
10.1201/9781003348443-27
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recent Italian earthquakes have dramatically demonstrated the high seismic vulnerability of industrial racks, raising awareness of the need to increase their seismic resilience in industry, academia, and society in general. Originally, these structures were conceived and designed to meet load-bearing requirements for static loads only. Although recent racking regulations contain clear requirements against seismic actions, most of the racks still in use today do not comply with them. To reduce their vulnerability, but also to increase the resilience of the newly designed racks, specific base isolation systems have recently been studied as an alternative to conventional strengthening solutions (e.g. thicker profiles, bracing systems). In this context, the Load-Level Isolation System (LLIS), i.e. the isolation system directly applied to some load levels of the rack, represents a new and interesting seismic mitigation technique, which deserves to be further explored. When properly designed, the LLIS allows the load units to act as tuned mass dampers, thus controlling the dynamic response of the structure. This paper aims to evaluate the effectiveness of the LLIS by analyzing a 5-span, 7-level case study rack, with the RBRL isolation system applied to the top two levels. The structure is analyzed through 3D finite element modeling and time-history analysis, using a set of bidirectional natural events. The effects of the LLIS are evaluated in terms of displacement and acceleration profiles, as well as axial and shear forces at the base of some uprights. These results are compared with those obtained by the same rack without LLIS and by the latter strengthened by means of a longitudinal bracing system, thus demonstrating the potential of the LLIS. Specifically, it is sufficient to isolate a few load levels to obtain significant reductions in the displacement profiles and in the maximum forces at the base of the structure.
引用
收藏
页码:172 / 178
页数:7
相关论文
共 50 条
  • [41] Application of ORFPM system for lean implementation: an industrial case study
    Joseph C. Chen
    Kuen-Min Chen
    The International Journal of Advanced Manufacturing Technology, 2014, 72 : 839 - 852
  • [42] Systemic Analysis of an Industrial System: Case Study of a Grain Silo
    Lakhoua, Mohamed Najeh
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2013, 38 (05): : 1243 - 1254
  • [43] Exploring Test Overlap in System Integration: An Industrial Case Study
    Flemstrom, Daniel
    Afzal, Wasif
    Sundmark, Daniel
    2016 42ND EUROMICRO CONFERENCE ON SOFTWARE ENGINEERING AND ADVANCED APPLICATIONS (SEAA), 2016, : 303 - 308
  • [44] SIMULATION OF AN INDUSTRIAL COMPUTER-SYSTEM - CASE-STUDY
    DICKERT, BF
    ZANAKIS, SH
    COMPUTERS & INDUSTRIAL ENGINEERING, 1979, 3 (03) : 203 - 215
  • [45] Control of BeoSound 9000 sledge system: An industrial case study
    Yang, Zhenyu
    Pedersen, Gerulf K. M.
    2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS, 2007, : 2928 - 2933
  • [46] Case Study: Optimization of an Industrial Steam Boiler System Operation
    Zhang, Bei
    Li, Yunhua
    Liu, Mingsheng
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 2, 2014, 120
  • [47] Towards an Energy Management System of Systems: An Industrial Case Study
    Mora, D.
    Taisch, M.
    Colombo, A. W.
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 5811 - 5816
  • [48] System level simulation of digital designs: A case study
    Carter, G.R.
    Inggs, M.R.
    Proceedings of the South African Symposium on Communications and Signal Processing, COMSIG, 1998, : 229 - 232
  • [49] Localization Transformation of Industrial Residential System: A Case Study on SI System in China
    Zou, J.M.
    Tang, S.N.
    IOP Conference Series: Materials Science and Engineering, 2019, 592 (01)
  • [50] System level simulation of digital designs: A case study
    Carter, GR
    Inggs, MR