Load-Level Isolation System for industrial racks: Evaluations on a case study structure

被引:0
|
作者
Bernardi, E. [1 ,2 ]
Dona, M. [1 ,2 ]
Zonta, A. [2 ]
Ceresara, M. [2 ]
Mozzon, S. [2 ]
da Porto, F. [2 ]
Tan, P. [3 ]
机构
[1] Guangzhou Univ, Earthquake Engn Res & Test Ctr, Guangzhou, Peoples R China
[2] Univ Padua, Dept Geosci, Padua, Italy
[3] Guangzhou Univ, Sch Civil Engn, Guangzhou, Peoples R China
关键词
COLUMN JOINTS;
D O I
10.1201/9781003348443-27
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recent Italian earthquakes have dramatically demonstrated the high seismic vulnerability of industrial racks, raising awareness of the need to increase their seismic resilience in industry, academia, and society in general. Originally, these structures were conceived and designed to meet load-bearing requirements for static loads only. Although recent racking regulations contain clear requirements against seismic actions, most of the racks still in use today do not comply with them. To reduce their vulnerability, but also to increase the resilience of the newly designed racks, specific base isolation systems have recently been studied as an alternative to conventional strengthening solutions (e.g. thicker profiles, bracing systems). In this context, the Load-Level Isolation System (LLIS), i.e. the isolation system directly applied to some load levels of the rack, represents a new and interesting seismic mitigation technique, which deserves to be further explored. When properly designed, the LLIS allows the load units to act as tuned mass dampers, thus controlling the dynamic response of the structure. This paper aims to evaluate the effectiveness of the LLIS by analyzing a 5-span, 7-level case study rack, with the RBRL isolation system applied to the top two levels. The structure is analyzed through 3D finite element modeling and time-history analysis, using a set of bidirectional natural events. The effects of the LLIS are evaluated in terms of displacement and acceleration profiles, as well as axial and shear forces at the base of some uprights. These results are compared with those obtained by the same rack without LLIS and by the latter strengthened by means of a longitudinal bracing system, thus demonstrating the potential of the LLIS. Specifically, it is sufficient to isolate a few load levels to obtain significant reductions in the displacement profiles and in the maximum forces at the base of the structure.
引用
收藏
页码:172 / 178
页数:7
相关论文
共 50 条
  • [21] Intelligent Electrical Load Shedding in Heavily Loaded Industrial Establishments with a Case Study
    Kucuk, Selahattin
    2018 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONIC ENGINEERING (ICEEE), 2018, : 463 - 467
  • [22] Short-term Industrial Load Forecasting: A Case Study in an Italian Factory
    Bracale, Antonio
    Carpinelli, Guido
    De Falco, Pasquale
    Hong, Tao
    2017 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2017,
  • [23] Long Term Effect of Power Factor Correction on the Industrial Load: A Case Study
    Zheng, Fu
    Zhang, Wang
    2017 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2017,
  • [24] Optimal Industrial Load Control in Smart Grid: A Case Study for Oil Refineries
    Gholian, Armen
    Mohsenian-Rad, Hamed
    Hua, Yingbo
    Qin, Joe
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [25] Modeling of Waste Flow in Industrial Symbiosis System at City-Region Level: A Case Study of Jinchang, China
    Lu, Chengpeng
    Pan, Xiaoli
    Chen, Xingpeng
    Mao, Jinhuang
    Pang, Jiaxing
    Xue, Bing
    SUSTAINABILITY, 2021, 13 (02) : 1 - 17
  • [26] Faults detection and isolation based on PCA: An industrial reheating furnace case study
    Liang, J
    Wang, N
    2003 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS, VOLS 1-5, CONFERENCE PROCEEDINGS, 2003, : 1193 - 1198
  • [27] Computational analysis of structure manufactured by means of the steel framing system. Case study: industrial warehouse
    Fajardo, J. I.
    Paltan, C. A.
    Palacios, E. G.
    WORKSHOP ON MODELING AND SIMULATION FOR SCIENCE AND ENGINEERING, V WMSSE, 2023, 2516
  • [28] Investigating the Relationship between the Industrial Structure and Atmospheric Environment by an Integrated System: A Case Study of Zhejiang, China
    Ding, Lei
    Chen, Kunlun
    Hua, Yidi
    Dong, Hongan
    Wu, Anping
    SUSTAINABILITY, 2020, 12 (03)
  • [29] Study on a system frequency response model for a large industrial area load shedding
    Zhao, QS
    Chen, C
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (03) : 233 - 237
  • [30] Application of a system level model to study the planetary load sharing behavior
    Singh, A
    JOURNAL OF MECHANICAL DESIGN, 2005, 127 (03) : 469 - 476