Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength

被引:11
|
作者
Ogawa, Masato [1 ,2 ]
Matsumoto, Tsuyoshi [3 ]
Harada, Risa [3 ]
Yoshikawa, Ryo [3 ]
Ueda, Yuya [4 ]
Takamiya, Daiki [3 ]
Sakai, Yoshitada [3 ]
机构
[1] Kobe Univ Hosp, Div Rehabil Med, Kobe, Japan
[2] Kobe Univ, Grad Sch Hlth Sci, Dept Publ Hlth, Kobe, Japan
[3] Kobe Univ, Grad Sch Med, Div Rehabil Med, Kobe, Japan
[4] Kobe Univ, Grad Sch Hlth Sci, Dept Rehabil Med, Kobe, Japan
关键词
muscle thickness; reliability; ultrasonography; validity; BODY-COMPOSITION; ULTRASOUND;
D O I
10.2490/prm.20230008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment. Methods: The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference. Results: The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant. Conclusions: Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Muscle thickness and echo-intensity changes of the quadriceps femoris muscle during a strength training program
    Santos, R.
    Valamatos, M. J.
    Mil-Homens, P.
    Armada-da-Silva, P. A. S.
    RADIOGRAPHY, 2018, 24 (04) : E75 - E84
  • [22] Effects of respiratory disease and age in quadriceps muscle mass: a pilot study with ultrasonography
    Martins, Paula
    Noronha, Laura
    Andre, Alexandra
    Paixao, Catia
    Rebelo, Patricia
    Oliveira, Ana
    De Francesco, Silvia
    Marques, Alda
    ANNALS OF MEDICINE, 2021, 53 : S83 - S84
  • [23] Effects of TheraBand and Theratube Eccentric Exercises on Quadriceps Muscle Strength and Muscle Mass in Young Adults
    Anwer, Shahnawaz
    Jeelani, Shayista I.
    Khan, Sohrab Ahmad
    Quddus, Nishat
    Kalra, Sumit
    Alghadir, Ahmad H.
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [24] Reliability of point-of-care ultrasound for measuring quadriceps femoris muscle thickness
    Pinto-Ramos, Joao
    Costa-Santos, Cristina
    Costa, Frederico
    Tavares, Helena
    Cabral, Joao
    Moreira, Tiago
    Brito, Rui
    Barroso, Joana
    Sousa-Pinto, Bernardo
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (05) : 767 - 773
  • [25] Validity of ultrasonograph muscle thickness measurements for estimating muscle volume of knee extensors in humans
    Miyatani, M
    Kanehisa, H
    Kuno, S
    Nishijima, T
    Fukunaga, T
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 86 (03) : 203 - 208
  • [26] Validity of ultrasonograph muscle thickness measurements for estimating muscle volume of knee extensors in humans
    Masae Miyatani
    Hiroaki Kanehisa
    Shinya Kuno
    Takahiko Nishijima
    Tetsuo Fukunaga
    European Journal of Applied Physiology, 2002, 86 : 203 - 208
  • [27] Ultrasonographic Measurements of Paraspinal Muscle Thickness in Adolescent Idiopathic Scoliosis: A Comparison and Reliability Study
    Zapata, Karina A.
    Wang-Price, Sharon S.
    Sucato, Daniel J.
    Dempsey-Robertson, Molly
    PEDIATRIC PHYSICAL THERAPY, 2015, 27 (02) : 119 - 125
  • [28] The concurrent validity of a portable ultrasound probe for muscle thickness measurements
    Homer, Kai A.
    Cross, Matt R.
    Jukic, Ivan
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2025, 45 (01)
  • [29] Reliability and Validity of Cervical Range of Motion and Muscle Strength Testing
    Kubas, Christian
    Chen, Yi-Wen
    Echeverri, Silvana
    McCann, Stephanie L.
    Denhoed, Marcia J.
    Walker, Catherine J.
    Kennedy, Carol N.
    Reid, W. Darlene
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (04) : 1087 - 1096
  • [30] Validity and reliability of isokinetic strength ratios for estimating muscle imbalances
    Ayala, Francisco
    Sainz de Baranda, Pilar
    de Ste Croix, Mark
    Santonja, Fernando
    APUNTS-MEDICINA DE L ESPORT, 2012, 47 (176) : 131 - 142