Self-Gated Radial Free-Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3 T

被引:1
|
作者
Kafali, Sevgi Gokce [1 ,2 ]
Bolster Jr, Bradley D. [3 ]
Shih, Shu-Fu [1 ,2 ]
Delgado, Timoteo I. [1 ,4 ]
Deshpande, Vibhas [5 ]
Zhong, Xiaodong [1 ,2 ,4 ]
Adamos, Timothy R. [6 ]
Ghahremani, Shahnaz [1 ]
Calkins, Kara L. [6 ]
Wu, Holden H. [1 ,2 ,4 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Siemens Med Solut USA Inc, US MR R&D Collaborat, Salt Lake City, UT USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Phys & Biol Med Interdept Program, Los Angeles, CA 90095 USA
[5] Siemens Med Solut USA Inc, US MR R&D Collaborat, Austin, TX USA
[6] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pediat, Los Angeles, CA 90095 USA
基金
美国国家卫生研究院;
关键词
free-breathing; radial sampling; liver MR elastography; fibrosis; children; liver stiffness; MAGNETIC-RESONANCE ELASTOGRAPHY; HEPATIC-FIBROSIS; STIFFNESS;
D O I
10.1002/jmri.29541
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional liver magnetic resonance elastography (MRE) requires breath-holding (BH) to avoid motion artifacts, which is challenging for children. While radial free-breathing (FB)-MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction. Purpose: To reduce FB-MRE scan time to 4 minutes for four slices and to investigate the impact of self-gated (SG) motion compensation on FB-MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH-MRE. Study Type: Prospective. Population: Twenty-six children without fibrosis (median age: 12.9 years, 15 females). Field Strength/Sequence: 3 T; Cartesian gradient-echo (GRE) BH-MRE, research application radial GRE FB-MRE. Assessment: Participants were scanned twice to measure repeatability, without moving the table or changing the participants' position. LS was measured in areas of the liver with numerical confidence >= 90%. Technical quality was examined using measurable liver area (%). Statistical Tests: Agreement of LS between BH-MRE and FB-MRE was evaluated using Bland-Altman analysis for SG acceptance rates of 40%, 60%, 80%, and 100%. LS repeatability was assessed using within-subject coefficient of variation (wCV). The differences in LS and measurable liver area were examined using Kruskal-Wallis and Wilcoxon signed-rank tests. P < 0.05 was considered significant. Results: FB-MRE with 60% SG achieved the closest agreement with BH-MRE (mean difference 0.00 kPa). The LS ranged from 1.70 to 1.83 kPa with no significant differences between BH-MRE and FB-MRE with varying SG rates (P = 0.52). All tested methods produced repeatable LS with wCV from 4.4% to 6.5%. The median measurable liver area was smaller for FB-MRE (32%-45%) than that for BH-MRE (91%-93%) (P < 0.05). Data Conclusion: FB-MRE with 60% SG can quantify LS with close agreement and comparable repeatability with respect to BH-MRE in children. Level of Evidence: 2 Technical Efficacy: Stage 1
引用
收藏
页码:1271 / 1283
页数:13
相关论文
共 50 条
  • [31] Fast isotropic volumetric coronary MR angiography using free-breathing 3D radial balanced FFE acquisition
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Dössell, O
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 197 - 203
  • [32] Simultaneous Multislice Accelerated Free-Breathing Diffusion-Weighted Imaging of the Liver at 3T
    Obele, Chika C.
    Glielmi, Christopher
    Ream, Justin
    Doshi, Ankur
    Campbell, Naomi
    Zhang, Hoi Cheung
    Babb, James
    Bhat, Himanshu
    Chandarana, Hersh
    ABDOMINAL IMAGING, 2015, 40 (07): : 2323 - 2330
  • [33] Left ventricular volume measurements with free breathing respiratory self-gated 3-dimensional golden angle radial whole-heart cine imaging - Feasibility and reproducibility
    Holst, Karen
    Ugander, Martin
    Sigfridsson, Andreas
    MAGNETIC RESONANCE IMAGING, 2017, 43 : 48 - 55
  • [34] Simultaneous Multislice Accelerated Free-Breathing Diffusion-Weighted Imaging of the Liver at 3T
    Chika C. Obele
    Christopher Glielmi
    Justin Ream
    Ankur Doshi
    Naomi Campbell
    Hoi Cheung Zhang
    James Babb
    Himanshu Bhat
    Hersh Chandarana
    Abdominal Imaging, 2015, 40 : 2323 - 2330
  • [35] Free-breathing Sparse Sampling Cine MR Imaging with Iterative Reconstruction for the Assessment of Left Ventricular Function and Mass at 3.0 T
    Sudarski, Sonja
    Henzler, Thomas
    Haubenreisser, Holger
    Doesch, Christina
    Zenge, Michael O.
    Schmidt, Michaela
    Nadar, Mariappan S.
    Borggrefe, Martin
    Schoenberg, Stefan O.
    Papavassiliu, Theano
    RADIOLOGY, 2017, 282 (01) : 74 - 83
  • [36] Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling
    Spuentrup, E
    Katoh, M
    Stuber, M
    Botnar, R
    Schaeffter, T
    Buecker, A
    Günther, RW
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (10): : 1330 - 1334
  • [37] Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system
    Zhang, Xiaoyong
    Qiu, Bensheng
    Wei, Zijun
    Yan, Fei
    Shi, Caiyun
    Su, Shi
    Liu, Xin
    Ji, Jim X.
    Xie, Guoxi
    PLOS ONE, 2017, 12 (12):
  • [38] Nonrigid Motion Modeling of the Liver From 3-D Undersampled Self-Gated Golden-Radial Phase Encoded MRI
    Buerger, C.
    Clough, R. E.
    King, A. P.
    Schaeffter, T.
    Prieto, C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 805 - 815
  • [39] Free-breathing high-resolution respiratory-gated radial stack-of-stars magnetic resonance imaging of the upper abdomen at 7 T
    Maatman, Ivo T.
    Schulz, Jenni
    Ypma, Sjoerd
    Block, Kai Tobias
    Schmitter, Sebastian
    Hermans, John J.
    Smit, Ewoud J.
    Maas, Marnix C.
    Scheenen, Tom W. J.
    NMR IN BIOMEDICINE, 2024, 37 (10)
  • [40] Feasibility of free-breathing T1-weighted 3D radial VIBE for fetal MRI in various anomalies
    Sun, Taotao
    Jiang, Ling
    Zhang, Zhongshuai
    Zhang, Chen
    Zhang, He
    Wang, Guangbin
    Qian, Zhaoxia
    MAGNETIC RESONANCE IMAGING, 2020, 69 : 57 - 64