Self-Gated Radial Free-Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3 T

被引:1
|
作者
Kafali, Sevgi Gokce [1 ,2 ]
Bolster Jr, Bradley D. [3 ]
Shih, Shu-Fu [1 ,2 ]
Delgado, Timoteo I. [1 ,4 ]
Deshpande, Vibhas [5 ]
Zhong, Xiaodong [1 ,2 ,4 ]
Adamos, Timothy R. [6 ]
Ghahremani, Shahnaz [1 ]
Calkins, Kara L. [6 ]
Wu, Holden H. [1 ,2 ,4 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Siemens Med Solut USA Inc, US MR R&D Collaborat, Salt Lake City, UT USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Phys & Biol Med Interdept Program, Los Angeles, CA 90095 USA
[5] Siemens Med Solut USA Inc, US MR R&D Collaborat, Austin, TX USA
[6] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pediat, Los Angeles, CA 90095 USA
基金
美国国家卫生研究院;
关键词
free-breathing; radial sampling; liver MR elastography; fibrosis; children; liver stiffness; MAGNETIC-RESONANCE ELASTOGRAPHY; HEPATIC-FIBROSIS; STIFFNESS;
D O I
10.1002/jmri.29541
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Conventional liver magnetic resonance elastography (MRE) requires breath-holding (BH) to avoid motion artifacts, which is challenging for children. While radial free-breathing (FB)-MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction. Purpose: To reduce FB-MRE scan time to 4 minutes for four slices and to investigate the impact of self-gated (SG) motion compensation on FB-MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH-MRE. Study Type: Prospective. Population: Twenty-six children without fibrosis (median age: 12.9 years, 15 females). Field Strength/Sequence: 3 T; Cartesian gradient-echo (GRE) BH-MRE, research application radial GRE FB-MRE. Assessment: Participants were scanned twice to measure repeatability, without moving the table or changing the participants' position. LS was measured in areas of the liver with numerical confidence >= 90%. Technical quality was examined using measurable liver area (%). Statistical Tests: Agreement of LS between BH-MRE and FB-MRE was evaluated using Bland-Altman analysis for SG acceptance rates of 40%, 60%, 80%, and 100%. LS repeatability was assessed using within-subject coefficient of variation (wCV). The differences in LS and measurable liver area were examined using Kruskal-Wallis and Wilcoxon signed-rank tests. P < 0.05 was considered significant. Results: FB-MRE with 60% SG achieved the closest agreement with BH-MRE (mean difference 0.00 kPa). The LS ranged from 1.70 to 1.83 kPa with no significant differences between BH-MRE and FB-MRE with varying SG rates (P = 0.52). All tested methods produced repeatable LS with wCV from 4.4% to 6.5%. The median measurable liver area was smaller for FB-MRE (32%-45%) than that for BH-MRE (91%-93%) (P < 0.05). Data Conclusion: FB-MRE with 60% SG can quantify LS with close agreement and comparable repeatability with respect to BH-MRE in children. Level of Evidence: 2 Technical Efficacy: Stage 1
引用
收藏
页码:1271 / 1283
页数:13
相关论文
共 50 条
  • [21] Automatic self-gated 4D-MRI construction from free-breathing 2D acquisitions applied on liver images
    Liset Vázquez Romaguera
    Nils Olofsson
    Rosalie Plantefève
    Elodie Lugez
    Jacques De Guise
    Samuel Kadoury
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 933 - 944
  • [22] Free-Breathing 3D Imaging of Right Ventricular Structure and Function Using Respiratory and Cardiac Self-Gated Cine MRI
    Zhu, Yanchun
    Liu, Jing
    Weinsaft, Jonathan
    Spincemaille, Pascal
    Nguyen, Thanh D.
    Prince, Martin R.
    Bao, Shanglian
    Xie, Yaoqin
    Wang, Yi
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [23] Automatic self-gated 4D-MRI construction from free-breathing 2D acquisitions applied on liver images
    Romaguera, Liset Vazquez
    Olofsson, Nils
    Plantefeve, Rosalie
    Lugez, Elodie
    De Guise, Jacques
    Kadoury, Samuel
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (06) : 933 - 944
  • [24] Uncertainty-aware physics-driven deep learning network for free-breathing liver fat and R2 quantification using self-gated stack-of-radial MRI
    Shih, Shu-Fu
    Kafali, Sevgi Gokce
    Calkins, Kara L.
    Wu, Holden H. H.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1567 - 1585
  • [25] Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory
    Usman, M.
    Ruijsink, B.
    Nazir, M. S.
    Cruz, G.
    Prieto, C.
    MAGNETIC RESONANCE IMAGING, 2017, 38 : 129 - 137
  • [26] Free-breathing 3D CEST MRI of human liver at 3.0 T
    Han, Pei
    Cheema, Karandeep
    Cao, Tianle
    Lee, Hsu-Lei
    Han, Fei
    Wang, Nan
    Han, Hui
    Xie, Yibin
    Christodoulou, Anthony G.
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (02) : 738 - 745
  • [27] Nonenhanced Free-Breathing ECG-Gated Steady-State Free Precession 3D MR Angiography of the Renal Arteries: Comparison Between 1.5 T and 3 T
    Lanzman, Rotem Shlomo
    Kroepil, Patric
    Schmitt, Peter
    Freitag, Sonja-Marie
    Ringelstein, Adrian
    Wittsack, Hans Joerg
    Blondin, Dirk
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (03) : 794 - 798
  • [28] Free-Breathing Single Navigator Gated Cine Cardiac Magnetic Resonance at 3 T: Feasibility Study in Patients
    Abd-Elmoniem, Khaled Z.
    Obele, Chika C.
    Sibley, Christopher T.
    Matta, Jatin R.
    Pettigrew, Roderic I.
    Gharib, Ahmed M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (03) : 382 - 386
  • [29] Free-breathing liver fat quantification using a multiecho 3D stack-of-radial technique
    Armstrong, Tess
    Dregely, Isabel
    Stemmer, Alto
    Han, Fei
    Natsuaki, Yutaka
    Sung, Kyunghyun
    Wu, Holden H.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 370 - 382
  • [30] Free-breathing self-gated continuous-IR spiral T1 mapping: Comparison of dual flip-angle and Bloch-Siegert B1-corrected techniques
    Zhou, Ruixi
    Wang, Junyu
    Weller, Daniel S.
    Yang, Yang
    Mugler, John P., III
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (03) : 1068 - 1080