Enhanced Cadmium Sensing in Fertilizer Samples using Zeolite-modified Graphite Electrode

被引:1
|
作者
Baha, Abdellah Ait [1 ]
Rachid, Idouhli [1 ]
Tabit, Kamal [2 ]
Aboulaich, Abdelmaula [3 ]
Khadiri, Mohy Eddine [1 ]
Dikici, Burak [4 ]
Abouelfida, Abdesselam [1 ]
机构
[1] Cadi Ayyad Univ, Fac Sci Semlalia, Dept Chem, Lab Appl Chem & Biomass, BP 2390, Marrakech, Morocco
[2] Sultan Moulay Slimane Univ, Natl Sch Appl Sci, LIPIM Lab, POB 77, Khouribga, Morocco
[3] Mohammed VI Polytech Univ UM6P, Geol & Sustainable Min Inst GSMI, Lot 660, Benguerir, Morocco
[4] Ataturk Univ, Fac Engn, Dept Mech Engn, TR-25240 Erzurum, Istanbul, Turkiye
关键词
zeolite-graphite electrode; Na-P1; zeolite; square wave voltammetry; heavy metals detection; ANODIC-STRIPPING VOLTAMMETRY; CARBON-PASTE ELECTRODE; HEAVY-METAL IONS; NANOTUBE-MODIFIED ELECTRODE; ELECTROCHEMICAL DETECTION; GLASSY-CARBON; EXPERIMENTAL-DESIGN; FLY-ASH; SENSOR; ADSORPTION;
D O I
10.1149/1945-7111/ad4acb
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The presence of heavy metals in fertilizers poses significant environmental and health risks, necessitating robust detection methods to ensure agricultural sustainability and food safety. This study focuses on synthesizing Na-P1 zeolite from coal fly ash and fumed silica wastes, employing it as a potent modifier in graphite electrodes to enhance the electrochemical detection of cadmium (II) in fertilizer samples. Through meticulous assessment using cyclic voltammetry (CV) in a potential window of -1.2 V to 0.5 V, square wave voltammetry (SWV) in a potential region of -1 V to 0.5 V, and electrochemical impedance spectroscopy (EIS) in a frequency ranging from 100 kHz to 10 mHz under open circuit potential polarization, the electrochemical performance of the zeolite-modified graphite electrode (ZGE) was evaluated. The optimization process involved fine-tuning various parameters such as paste composition, solution pH, scan rate, and analyte concentration. Real sample analysis confirmed the applicability of the method in fertilizer samples. Notably, in an HCl medium (pH = 1.0), the SWV oxidation peak of Cd(II) was observed at -0.56 V (vs SCE) with a deposition time of 20 s and a scan rate of 75 mV center dot s-1. The ZGE exhibited a remarkable detection limit of 1 mu M, a quantification limit of 5 mu M, and a high sensitivity of 6.581 mu A/mu M.cm2 within a linear detection range of 10-3-10-6 M. These findings highlight the potential utility of Na-P1 zeolite in handheld analytic device manufacturing, offering promising applications in environmental monitoring, resource management, and water and soil resource remediation. Hydrothermal synthesis of Na-P1 zeolite from the industrial by-products. Preparation of zeolite-modified graphite electrode for electrochemical detection of cadmium. Immediate and reliable electrochemical detection of cadmium in fertilizer samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Voltammetric determination of cadmium using magnetic graphite-epoxy composite electrode modified with magnetic nanoparticles
    dos Santos, Paula Mantovani
    Gorla, Felipe Augusto
    Wong, Ademar
    Corazza, Marcela Zanetti
    Sotomayor, Maria D. P. T.
    Tarley, Cesar Ricardo Teixeira
    TALANTA, 2025, 292
  • [42] Theoretical and electrochemical analysis of L-serine modified graphite paste electrode for dopamine sensing applications in real samples
    Kumar, Revanappa Santhosh
    Jayaprakash, Gururaj Kudur
    Manjappa, Siddalinganahalli
    Kumar, Mohan
    Kumar, Avvaru Praveen
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, : 1243 - 1250
  • [43] Potentiometric sensor for chromium(VI) using a composite of diphenylcarbazide-natural zeolite-modified membrane electrodes
    Heryanto, Rudi
    Rohaeti, Eti
    Wulansari, Laela
    Arif, Zulhan
    Wahyuni, Wulan Tri
    Putra, Budi Riza
    SCIENCEASIA, 2022, 48 (04): : 434 - 442
  • [44] Procollagen type 1 N-terminal propeptide immunoassay on zeolite-modified gold interdigitated electrode for diagnosing osteoporosis
    Han, Xiaoqiang
    Su, Zhanglei
    Liu, Qiang
    Gopinath, Subash C. B.
    Chen, Jing
    MATERIALS EXPRESS, 2022, 12 (08) : 1042 - 1048
  • [45] DETERMINATION OF MERCURY(II) USING A MODIFIED ELECTRODE WITH ZEOLITE
    HERNANDEZ, P
    ALDA, E
    HERNANDEZ, L
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 327 (07): : 676 - 678
  • [46] Fe(III) doped zeolite-graphite composite modified glassy carbon electrode for selective voltammetric determination of resorcinol in water samples
    Amare, Meareg
    Begashaw, Mulie
    MICROCHEMICAL JOURNAL, 2019, 146 : 900 - 905
  • [47] Electrochemical Sensing of Formaldehyde in Fish Samples Using a Polydopamine-Modified Stainless Steel Electrode
    Philip, Angel Susan
    Rison, Sherin
    Cherian, Anila Rose
    Akshaya, K. B.
    George, Louis
    Varghese, Anitha
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2021, 10 (06)
  • [48] Sensing L-cysteine in urine using a pencil graphite electrode modified with a copper hexacyanoferrate nanostructure
    Mir Reza Majidi
    Karim Asadpour-Zeynali
    Behnam Hafezi
    Microchimica Acta, 2010, 169 : 283 - 288
  • [49] Electrochemical Sensing of Uric Acid Using a ZnO/Graphene Nanocomposite Modified Graphite Screen Printed Electrode
    Rezaei, Rasoul
    Foroughi, Mohammad Mehdi
    Beitollahi, Hadi
    Alizadeh, Reza
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2018, 54 (11) : 860 - 866
  • [50] Electrochemical Sensing of Isoproterenol using Graphite Screen-printed Electrode Modified with Graphene Quantum Dots
    Dourandish, Zahra
    Beitollahi, Hadi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (02): : 192 - 202