Enhanced Cadmium Sensing in Fertilizer Samples using Zeolite-modified Graphite Electrode

被引:1
|
作者
Baha, Abdellah Ait [1 ]
Rachid, Idouhli [1 ]
Tabit, Kamal [2 ]
Aboulaich, Abdelmaula [3 ]
Khadiri, Mohy Eddine [1 ]
Dikici, Burak [4 ]
Abouelfida, Abdesselam [1 ]
机构
[1] Cadi Ayyad Univ, Fac Sci Semlalia, Dept Chem, Lab Appl Chem & Biomass, BP 2390, Marrakech, Morocco
[2] Sultan Moulay Slimane Univ, Natl Sch Appl Sci, LIPIM Lab, POB 77, Khouribga, Morocco
[3] Mohammed VI Polytech Univ UM6P, Geol & Sustainable Min Inst GSMI, Lot 660, Benguerir, Morocco
[4] Ataturk Univ, Fac Engn, Dept Mech Engn, TR-25240 Erzurum, Istanbul, Turkiye
关键词
zeolite-graphite electrode; Na-P1; zeolite; square wave voltammetry; heavy metals detection; ANODIC-STRIPPING VOLTAMMETRY; CARBON-PASTE ELECTRODE; HEAVY-METAL IONS; NANOTUBE-MODIFIED ELECTRODE; ELECTROCHEMICAL DETECTION; GLASSY-CARBON; EXPERIMENTAL-DESIGN; FLY-ASH; SENSOR; ADSORPTION;
D O I
10.1149/1945-7111/ad4acb
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The presence of heavy metals in fertilizers poses significant environmental and health risks, necessitating robust detection methods to ensure agricultural sustainability and food safety. This study focuses on synthesizing Na-P1 zeolite from coal fly ash and fumed silica wastes, employing it as a potent modifier in graphite electrodes to enhance the electrochemical detection of cadmium (II) in fertilizer samples. Through meticulous assessment using cyclic voltammetry (CV) in a potential window of -1.2 V to 0.5 V, square wave voltammetry (SWV) in a potential region of -1 V to 0.5 V, and electrochemical impedance spectroscopy (EIS) in a frequency ranging from 100 kHz to 10 mHz under open circuit potential polarization, the electrochemical performance of the zeolite-modified graphite electrode (ZGE) was evaluated. The optimization process involved fine-tuning various parameters such as paste composition, solution pH, scan rate, and analyte concentration. Real sample analysis confirmed the applicability of the method in fertilizer samples. Notably, in an HCl medium (pH = 1.0), the SWV oxidation peak of Cd(II) was observed at -0.56 V (vs SCE) with a deposition time of 20 s and a scan rate of 75 mV center dot s-1. The ZGE exhibited a remarkable detection limit of 1 mu M, a quantification limit of 5 mu M, and a high sensitivity of 6.581 mu A/mu M.cm2 within a linear detection range of 10-3-10-6 M. These findings highlight the potential utility of Na-P1 zeolite in handheld analytic device manufacturing, offering promising applications in environmental monitoring, resource management, and water and soil resource remediation. Hydrothermal synthesis of Na-P1 zeolite from the industrial by-products. Preparation of zeolite-modified graphite electrode for electrochemical detection of cadmium. Immediate and reliable electrochemical detection of cadmium in fertilizer samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Zeolite-modified WO3 gas sensors - Enhanced detection of NO2
    Varsani, Priya
    Afonja, Ayo
    Williams, David E.
    Parkin, Ivan P.
    Binions, Russell
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 475 - 482
  • [22] Voltammetric response of the hexammino-ruthenium complex incorporated in zeolite-modified carbon paste electrode
    Walcarius, A
    Lamberts, L
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 422 (1-2) : 77 - 89
  • [23] Effect of NaX zeolite-modified graphite felts on hexavalent chromium removal in biocathode microbial fuel cells
    Wu, Xiayuan
    Tong, Fei
    Yong, Xiaoyu
    Zhou, Jun
    Zhang, Lixiong
    Jia, Honghua
    Wei, Ping
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 308 : 303 - 311
  • [24] Zeolite-modified electrodes for electrochemical sensing of heavy metal ions e Progress and future directions
    Thatikayala, D.
    Noori, M. T.
    Min, B.
    MATERIALS TODAY CHEMISTRY, 2023, 29
  • [25] CATION DETERMINATION IN AQUEOUS-SOLUTION USING THE METHYL VIOLOGEN-DOPED ZEOLITE-MODIFIED CARBON-PASTE ELECTRODE
    WALCARIUS, A
    LAMBERTS, L
    DEROUANE, EG
    ELECTROANALYSIS, 1995, 7 (02) : 120 - 128
  • [26] Electrochemical determination of p-cresol concentration using zeolite-modified electrodes
    Berge-Lefranc, David
    Eyraud, Marielle
    Schaef, Oliver
    COMPTES RENDUS CHIMIE, 2008, 11 (09) : 1063 - 1073
  • [27] Determination of bisphenol A in real samples using modified graphite screen-printed electrode
    Safavi Gerdin, Hesam
    Sarhadi, Hamid
    Tajik, Somayeh
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (17) : 4986 - 4995
  • [28] Zeolite-Modified Carbon-Paste Electrode as a Selective Voltammetric Sensor for Detection of Tryptophan in Pharmaceutical Preparations
    Arvand, Majid
    Zanjanchi, Mohammad A.
    Islamnezhad, Akbar
    ANALYTICAL LETTERS, 2009, 42 (04) : 727 - 738
  • [29] SIMPLEX OPTIMIZATION OF ELECTROREDUCTION OF OXYGEN MEDIATED BY METHYL VIOLOGEN SUPPORTED ON ZEOLITE-MODIFIED CARBON PASTE ELECTRODE
    CREASY, KE
    SHAW, BR
    ELECTROCHIMICA ACTA, 1988, 33 (04) : 551 - 556
  • [30] Simultaneous Electrochemical Sensing of Ceftriaxone and Piroxicam Using Zeolite Modified Electrode for Medical Applications
    Khosravi-Hamoleh, Amir
    Abrishamkar, Maryam
    Cheraghizade, Mohsen
    ELECTROANALYSIS, 2021, 33 (08) : 1866 - 1870