Use of Virtual Reality in the Education of Orthopaedic Procedures: A Randomised Control Study in Early Validation of a Novel Virtual Reality Simulator

被引:6
|
作者
Gomindes, Austin R. [1 ,2 ]
Adeeko, Elizabeth S. [3 ]
Khatri, Chetan [2 ,3 ]
Ahmed, Imran [2 ,3 ]
Sehdev, Simran [3 ]
Carlos, William John [2 ,3 ]
Ward, Thomas [2 ,3 ]
Leverington, James [2 ,3 ]
Debenham, Luke [2 ,3 ]
Metcalfe, Andrew [3 ]
Ward, Jayne [2 ]
机构
[1] Univ Birmingham, Sch Med & Dent Sci, Birmingham, England
[2] Univ Hosp Coventry & Warwickshire, Trauma & Orthopaed, Coventry, England
[3] Univ Warwick, Trauma & Orthopaed, Warwick, England
关键词
training effect; haptics; orthopaedics & traumatology; virtual reality in medical education; virtual reality simulation; virtual augmented reality; tfn-advanced proximal femoral nailing system (tfna); skills and simulation training; SURGICAL PERFORMANCE ANXIETY; SURGEONS; BURNOUT; TRIAL;
D O I
10.7759/cureus.45943
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Virtual reality (VR) simulation is a potential solution to the barriers surgical trainees are facing. There needs to be validation for its implementation within current training. We aimed to compare VR simulation to traditional methods in acquiring surgical skills for a TFN-ADVANCED (TM) Proximal Femoral Nailing System (TFNA; DePuy Synthes, Auckland, New Zealand) femoral nailing system. Methods Thirty-one surgical trainees were randomised to two groups: traditional-training group (control group) and a VR-training group (intervention group) for insertion of a short cephalomedullary TFNA nail. Both groups then inserted the same TFNA system into saw-bone femurs. Surveys evaluated validity of the relevant activities, perception of simulation, confidence, stress and anxiety. The primary outcomes were tip-apex distance (TAD) and user anxiety/confidence levels. Secondary outcomes included number of screw-and nail-guidewire insertion attempts, the time taken to complete and user validity of the VR system. Results There was no statistical difference in TAD between the intervention and control groups (9mm vs 15mm, p=0.0734). The only TAD at risk of cut-out was in the control group (25mm). There was no statistical difference in time taken (2547.5ss vs 2395ss, p=0.668), nail guide-wire attempts (two for both groups, p=0.355) and screw guide-wire attempts (one for both groups, p=0.702). The control group versus intervention had higher anxiety levels (50% vs 33%) and had lower confidence (61% vs 84%). Interpretation There was no objective difference in performance on a saw-bone model between groups. However, this VR simulator resulted in more confidence and lower anxiety levels whilst performing a simulated TFNA. Whilst further studies with larger sample sizes and exploration of transfer validity to the operating theatre are required, this study does indicate potential benefits of VR within surgical training.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A Novel Virtual Reality Assessment of Functional Cognition: Validation Study
    Porffy, Lilla Alexandra
    Mehta, Mitul A.
    Patchitt, Joel
    Boussebaa, Celia
    Brett, Jack
    D'Oliveira, Teresa
    Mouchlianitis, Elias
    Shergill, Sukhi S.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2022, 24 (01)
  • [42] External Validation of a Virtual Reality Transurethral Resection of the Prostate Simulator
    Hudak, Steven J.
    Landt, Cristy L.
    Hernandez, Javier
    Soderdahl, Douglas W.
    JOURNAL OF UROLOGY, 2010, 184 (05): : 2018 - 2022
  • [43] Validation of a virtual reality-based simulator for shoulder arthroscopy
    Rahm, Stefan
    Germann, Marco
    Hingsammer, Andreas
    Wieser, Karl
    Gerber, Christian
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (05) : 1730 - 1737
  • [44] Validation and learning in the Procedicus KSA virtual reality surgical simulator
    P. Ström
    A. Kjellin
    L. Hedman
    E. Johnson
    T. Wredmark
    L. Felländer-Tsai
    Surgical Endoscopy And Other Interventional Techniques, 2003, 17 : 227 - 231
  • [45] Validation of a Virtual Reality Simulator for Percutaneous Pedicle Screw Insertion
    Charalambous, Alexander
    Aftab, Syed
    Segaren, Neil
    Montgomery, Alexander
    Haldar, Anil
    Akhtar, Kashif
    Vaghela, Kalpesh R.
    Lee, Joshua K.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [46] Validation Study of a Virtual Reality Robotic Simulator-Role as an Assessment Tool?
    Lee, Jason Y.
    Mucksavage, Phillip
    Kerbl, David C.
    Huynh, Victor B.
    Etafy, Mohamed
    McDougall, Elspeth M.
    JOURNAL OF UROLOGY, 2012, 187 (03): : 998 - 1002
  • [47] 752 Evaluating the Use of Immersive Virtual Reality Simulation in Orthopaedic Trauma Cases; A Construct Reality Study
    Feeley, A.
    Sheehan, E.
    Merghani, K.
    BRITISH JOURNAL OF SURGERY, 2021, 108 (SUPPL 2)
  • [48] Virtual reality permanent pacing: validation of a novel computerised permanent pacemaker implantation simulator
    Wong, T
    Darzi, A
    Foale, RA
    Schilling, RJ
    EUROPEAN HEART JOURNAL, 2001, 22 : 222 - 222
  • [49] Virtual reality permanent pacing: Validation of a novel computerised permanent pacemaker implantation simulator
    Wong, T
    Darzi, A
    Foale, R
    Schilling, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 493A - 494A
  • [50] Creating a Smart Virtual Reality Simulator for Sports Training and Education
    Staurset, Emil Moltu
    Prasolova-Forland, Ekaterina
    SMART EDUCATION AND E-LEARNING 2016, 2016, 59 : 423 - 433