Use of Virtual Reality in the Education of Orthopaedic Procedures: A Randomised Control Study in Early Validation of a Novel Virtual Reality Simulator

被引:6
|
作者
Gomindes, Austin R. [1 ,2 ]
Adeeko, Elizabeth S. [3 ]
Khatri, Chetan [2 ,3 ]
Ahmed, Imran [2 ,3 ]
Sehdev, Simran [3 ]
Carlos, William John [2 ,3 ]
Ward, Thomas [2 ,3 ]
Leverington, James [2 ,3 ]
Debenham, Luke [2 ,3 ]
Metcalfe, Andrew [3 ]
Ward, Jayne [2 ]
机构
[1] Univ Birmingham, Sch Med & Dent Sci, Birmingham, England
[2] Univ Hosp Coventry & Warwickshire, Trauma & Orthopaed, Coventry, England
[3] Univ Warwick, Trauma & Orthopaed, Warwick, England
关键词
training effect; haptics; orthopaedics & traumatology; virtual reality in medical education; virtual reality simulation; virtual augmented reality; tfn-advanced proximal femoral nailing system (tfna); skills and simulation training; SURGICAL PERFORMANCE ANXIETY; SURGEONS; BURNOUT; TRIAL;
D O I
10.7759/cureus.45943
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Virtual reality (VR) simulation is a potential solution to the barriers surgical trainees are facing. There needs to be validation for its implementation within current training. We aimed to compare VR simulation to traditional methods in acquiring surgical skills for a TFN-ADVANCED (TM) Proximal Femoral Nailing System (TFNA; DePuy Synthes, Auckland, New Zealand) femoral nailing system. Methods Thirty-one surgical trainees were randomised to two groups: traditional-training group (control group) and a VR-training group (intervention group) for insertion of a short cephalomedullary TFNA nail. Both groups then inserted the same TFNA system into saw-bone femurs. Surveys evaluated validity of the relevant activities, perception of simulation, confidence, stress and anxiety. The primary outcomes were tip-apex distance (TAD) and user anxiety/confidence levels. Secondary outcomes included number of screw-and nail-guidewire insertion attempts, the time taken to complete and user validity of the VR system. Results There was no statistical difference in TAD between the intervention and control groups (9mm vs 15mm, p=0.0734). The only TAD at risk of cut-out was in the control group (25mm). There was no statistical difference in time taken (2547.5ss vs 2395ss, p=0.668), nail guide-wire attempts (two for both groups, p=0.355) and screw guide-wire attempts (one for both groups, p=0.702). The control group versus intervention had higher anxiety levels (50% vs 33%) and had lower confidence (61% vs 84%). Interpretation There was no objective difference in performance on a saw-bone model between groups. However, this VR simulator resulted in more confidence and lower anxiety levels whilst performing a simulated TFNA. Whilst further studies with larger sample sizes and exploration of transfer validity to the operating theatre are required, this study does indicate potential benefits of VR within surgical training.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Initial validation of a virtual-reality robotic simulator
    Lendvay T.S.
    Casale P.
    Sweet R.
    Peters C.
    Journal of Robotic Surgery, 2008, 2 (3) : 145 - 149
  • [22] Virtual Reality and Physical Models in Undergraduate Orthopaedic Education: A Modified Randomised Crossover Trial
    Wilson, Glen
    Zargaran, Alexander
    Kokotkin, Ilya
    Bhaskar, Jared
    Zargaran, David
    Trompeter, Alex
    ORTHOPEDIC RESEARCH AND REVIEWS, 2020, 12 : 97 - 104
  • [23] A virtual reality simulator for orthopedic basic skills: A design and validation study
    Vankipuram, Mithra
    Kahol, Kanav
    McLaren, Alex
    Panchanathan, Sethuraman
    JOURNAL OF BIOMEDICAL INFORMATICS, 2010, 43 (05) : 661 - 668
  • [24] USE OF VIRTUAL REALITY FOR ARTISTIC EDUCATION
    Nanu, A.
    Titieni, A.
    Nedelcu, M.
    Nedelcu, F.
    Sarbu, C.
    6TH INTERNATIONAL CONFERENCE OF EDUCATION, RESEARCH AND INNOVATION (ICERI 2013), 2013, : 47 - 56
  • [25] VALIDATION OF THE DV-TRAINER®, A NOVEL VIRTUAL REALITY SIMULATOR FOR ROBOTIC SURGERY
    Kenney, Patrick A.
    Wszolek, Matthew F.
    Gould, Justin J.
    Libertino, John A.
    Moinzadeh, Alireza
    JOURNAL OF UROLOGY, 2009, 181 (04): : 792 - 792
  • [26] Using a novel virtual-reality simulator to assess performance in lumbar puncture: a validation study
    Xie, Sujun
    Grimstrup, Soren
    Nayahangan, Leizl Joy
    Wang, Zheng
    Wan, Xing
    Konge, Lars
    BMC MEDICAL EDUCATION, 2023, 23 (01)
  • [27] A Novel Virtual Reality-Based Simulator for Maxillofacial Reconstruction Surgery: Development and Validation Study
    Kim, Jun-Seong
    Kim, Kun-Woo
    Kim, Hyo-Joon
    Moon, Seong-Yong
    APPLIED SCIENCES-BASEL, 2025, 15 (01):
  • [28] Using a novel virtual-reality simulator to assess performance in lumbar puncture: a validation study
    Sujun Xie
    Søren Grimstrup
    Leizl Joy Nayahangan
    Zheng Wang
    Xing Wan
    Lars Konge
    BMC Medical Education, 23
  • [29] Evaluating the Use of Immersive Virtual Reality Simulation in Orthopaedic Trauma Cases; A Construct Reality Study
    Feeley, A.
    Sheehan, E.
    Merghani, K.
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [30] A virtual reality simulator for training and rehearsal of sinus surgery procedures
    Pommert, A.
    Hoehne, K. H.
    Petersik, A.
    Pflesser, B.
    Tiede, U.
    Tolsdorff, B.
    Leuwer, R.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S231 - S233