Effect of High Intensity Wind Loads on Steel Poles Transmission Lines

被引:0
|
作者
Shehata, Ahmed [1 ]
Ahmed, Abdelrahman [1 ]
El Damatty, Ashraf [1 ,2 ]
机构
[1] Western Univ, London, ON, Canada
[2] Western Univ, WindEEE Res Inst, London, ON, Canada
关键词
Transmission lines; Steel poles; High intensity wind; Downbursts; Tornadoes; ASCE 74 (2020); PRESTRESSED CONCRETE POLES; FAILURE ANALYSIS; DOWNBURSTS; BEHAVIOR; TOWERS; DESIGN;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The vulnerability of transmission lines to high intensity wind (HIW) loads, such as downbursts and tornadoes, has been realized through several transmission lines failures around the world. Transmission poles are commonly used in urban and suburban high-voltage transmission lines. However, transmission poles can be more vulnerable to HIW loads than lattice transmission towers due to their limited redundancy. The study aims to investigate the sensitivity of steel poles transmission lines to downbursts and tornadoes. The critical load cases are determined by equating the peak straining actions due to HIW loads, to those obtained due to the synoptic wind and ice loads cases. HIW loads cases are calculated using the new provisions recently incorporated in ASCE 74 (2020) guidelines. The results of this study provide the magnitude of HIW loads beyond which the considered transmission poles are not safe, if they were designed to withstand only synoptic wind and ice loads cases without a margin of safety.
引用
收藏
页码:253 / 267
页数:15
相关论文
共 50 条
  • [41] LONGITUDINAL LOADS FROM BROKEN CONDUCTORS AND BROKEN INSULATORS AND THEIR EFFECT ON TRANSMISSION-LINES
    PEYROT, AH
    KLUGE, RO
    LEE, JW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (01): : 222 - 234
  • [42] Parallel computation of electric field intensity nearby high voltage transmission lines
    Li, Tianwei
    Ruan, Jiangjun
    Wu, Tian
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2009, 24 (07): : 1 - 6
  • [43] Calculation of electric field intensity of high voltage direct current transmission lines
    Lin, Xiu-Li
    Xu, Xin-Hua
    Wang, Da-Hui
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2007, 41 (08): : 1421 - 1426
  • [44] Assessing Galvanized Steel Power Transmission Poles and Towers for Corrosion
    Larsen, Kathy Riggs
    MATERIALS PERFORMANCE, 2016, 55 (12) : 24 - 28
  • [45] Influence of Types of Steel Poles on Measurements by Wind Speed Sensors along High-Speed Railways
    Zhang, J.
    Gao, G.
    Xiong, X.
    Liu, T.
    Liu, F.
    JOURNAL OF APPLIED FLUID MECHANICS, 2016, 9 (01) : 243 - 251
  • [46] Optimal Planning of ESS and Transmission Lines to Accommodate High Wind Power Integration
    Al-Ismail, Fahad Saleh
    2020 INTERNATIONAL CONFERENCE ON SMART GRIDS AND ENERGY SYSTEMS (SGES 2020), 2020, : 36 - 42
  • [47] FINITE-ELEMENT SOLUTION OF WOOD AND STEEL TRANSMISSION POLES
    PETERS, RC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (06): : 1809 - 1809
  • [48] Unit Transient Based Protection for High Voltage Wind Power Transmission Lines
    Xia, Mingchao
    Lin, Yong
    Lo, Edward W. C.
    INSTRUMENTATION, MEASUREMENT, CIRCUITS AND SYSTEMS, 2012, 127 : 205 - +
  • [49] Effect of Wind Loads on Collapse Performance and Seismic Loss for Steel Ordinary Moment Frames
    Kim, Taeo
    Han, Sang Whan
    Cho, Soo Ik
    APPLIED SCIENCES-BASEL, 2022, 12 (04):
  • [50] DESIGN WIND LOADS FOR OVERHEAD POWER-LINES ACCOUNTING FOR WIND DIRECTION
    KRISHNASAMY, SG
    RAMANI, N
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1989, 32 (1-2) : 63 - 72