Effect of High Intensity Wind Loads on Steel Poles Transmission Lines

被引:0
|
作者
Shehata, Ahmed [1 ]
Ahmed, Abdelrahman [1 ]
El Damatty, Ashraf [1 ,2 ]
机构
[1] Western Univ, London, ON, Canada
[2] Western Univ, WindEEE Res Inst, London, ON, Canada
关键词
Transmission lines; Steel poles; High intensity wind; Downbursts; Tornadoes; ASCE 74 (2020); PRESTRESSED CONCRETE POLES; FAILURE ANALYSIS; DOWNBURSTS; BEHAVIOR; TOWERS; DESIGN;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The vulnerability of transmission lines to high intensity wind (HIW) loads, such as downbursts and tornadoes, has been realized through several transmission lines failures around the world. Transmission poles are commonly used in urban and suburban high-voltage transmission lines. However, transmission poles can be more vulnerable to HIW loads than lattice transmission towers due to their limited redundancy. The study aims to investigate the sensitivity of steel poles transmission lines to downbursts and tornadoes. The critical load cases are determined by equating the peak straining actions due to HIW loads, to those obtained due to the synoptic wind and ice loads cases. HIW loads cases are calculated using the new provisions recently incorporated in ASCE 74 (2020) guidelines. The results of this study provide the magnitude of HIW loads beyond which the considered transmission poles are not safe, if they were designed to withstand only synoptic wind and ice loads cases without a margin of safety.
引用
收藏
页码:253 / 267
页数:15
相关论文
共 50 条
  • [31] RLC circuits match transmission lines to loads
    Dvoskin, B
    EDN, 1997, 42 (08) : 126 - &
  • [32] Refinement of Wind Loads on Lattice Support Structures of the Intersystem Overhead Power Transmission Lines 750 kV
    Shevchenko, Yevgeny
    Nazim, Yaroslav
    Tanasoglo, Anton
    Garanzha, Igor
    INTERNATIONAL SCIENTIFIC CONFERENCE URBAN CIVIL ENGINEERING AND MUNICIPAL FACILITIES (SPBUCEMF-2015), 2015, 117 : 1028 - 1035
  • [33] Wind Tunnel Test for Wind Loads of Transmission Tower Leg in Skew Wind
    Hu X.
    Zhang D.
    Song X.
    Deng H.
    Tongji Daxue Xuebao/Journal of Tongji University, 2022, 50 (04): : 511 - 517
  • [34] Analysis of the Shielding Effect of Distribution Lines on Electric Field Intensity Near UHVAC Transmission Lines
    Li, Haiqiong
    Zhang, Jiangong
    Wang, Yanzhao
    Gan, Zheyuan
    Xu, Jilai
    Fan, Yutong
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 305 - 309
  • [35] Concrete prestressed poles in the high voltage lines
    Michalek, J.
    INTERNATIONAL SCIENTIFIC CONFERENCE ENERGY MANAGEMENT OF MUNICIPAL FACILITIES AND SUSTAINABLE ENERGY TECHNOLOGIES, 2020, 1614
  • [36] Damping of steel poles and monotubular towers under wind action
    Pagnini, LC
    Solari, G
    WIND ENGINEERING INTO THE 21ST CENTURY, VOLS 1-3, 1999, : 509 - 516
  • [37] Design wind loads for tubular-angle steel cross-arms of transmission towers under skewed wind loading
    Yang, Fengli
    Yang, Jingbo
    Niu, Huawei
    Zhang, Hongjie
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 140 : 10 - 18
  • [38] COMPOSITE CONCRETE-STEEL TRANSMISSION POLES WITH PRESTRESSED STEEL SHELLS.
    Romualdi, James P.
    Pohlman, Joe C.
    1979,
  • [39] Wind and sleet loads on the aerial power lines in Ukraine
    Horokhov, YV
    Nazim, YV
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2001, 89 (14-15) : 1409 - 1419
  • [40] LONGITUDINAL LOADS FROM BROKEN CONDUCTORS AND BROKEN INSULATORS AND THEIR EFFECT ON TRANSMISSION LINES.
    Peyrot, Alain H.
    Kluge, Robert O.
    Lee, Jun W.
    1979,