Comparison of wear and fracture resistance of additively and subtractively manufactured screw-retained, implant-supported crowns

被引:11
|
作者
Turksayar, Almira Ada Diken [1 ,2 ]
Demirel, Munir [3 ]
Donmez, Mustafa Borga [1 ,4 ]
Olcay, Emin Orkun [1 ]
Eyuboglu, Tan Firat [5 ]
Ozcan, Mutlu [6 ]
机构
[1] Biruni Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Carinthia Univ Appl Sci, ADMiRE Res Ctr Addit Mfg Intelligent Robot Sensors, Sch Engn & IT, Villach, Austria
[3] Biruni Univ, Vocat Sch, Oral & Dent Hlth, Istanbul, Turkiye
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3007 Bern, Switzerland
[5] Istanbul Medipol Univ, Fac Dent, Dept Endodont, Istanbul, Turkiye
[6] Univ Zurich, Ctr Dent Med, Clin Masticatory Disorders & Dent Biomat, Zurich, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2024年 / 132卷 / 01期
关键词
ZIRCONIA; PERFORMANCE; SURVIVAL;
D O I
10.1016/j.prosdent.2023.06.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Additively manufactured resins indicated for fixed definitive prostheses have been recently marketed. However, knowledge on their wear and fracture resistance when fabricated as screw-retained, implant-supported crowns and subjected to artificial aging is limited. Purpose. The purpose of this in vitro study was to evaluate the volume loss, maximum wear depth, and fracture resistance of screwretained implant-supported crowns after thermomechanical aging when fabricated using additively and subtractively manufactured materials. Material and methods. Two additively manufactured composite resins (Crowntec [CT] and VarseoSmile Crown Plus [VS]) and 2 subtractively manufactured materials (1 reinforced composite resin, Brilliant Crios [BC] and 1 polymer-infiltrated ceramic network, Vita Enamic [EN]) were used to fabricate standardized screw-retained, implant-supported crowns. After fabrication, the crowns were cemented on titanium base abutments and then tightened to implants embedded in acrylic resin. A laser scanner with a triangular displacement sensor (LAS -20) was used to digitize the pre-aging state of the crowns. Then, all crowns were subjected to thermomechanical aging (1.2 million cycles under 50 N) and rescanned. A metrology-grade analysis software program (Geomagic Control X 2020.1) was used to superimpose post-aging scans over pre-aging scans to calculate the volume loss (mm3) and maximum wear depth (mm). Finally, all crowns were subjected to a fracture resistance test. Fracture resistance and volume loss were evaluated by using 1-way analysis of variance and Tukey Honestly significant difference (HSD) tests, whereas the Kruskal-Wallis and Dunn tests were used to analyze maximum wear depth. Chisquared tests were used to evaluate the Weibull modulus and characteristic strength data (alpha=.05). Results. Material type affected the tested parameters (P .001). CT and VS had higher volume loss and maximum wear depth than BC and EN (P .001). EN had the highest fracture resistance among tested materials (P .001), whereas BC had higher fracture resistance than CT (P=.011). The differences among tested materials were not significant when the Weibull modulus was considered (P=.199); however, VE had the highest characteristic strength (P .001). Conclusions. Additively manufactured screw-retained, implant-supported crowns had higher volume loss and maximum wear depth. All materials had fracture resistance values higher than the previously reported masticatory forces of the premolar region; however, the higher characteristic strength of the subtractively manufactured polymer-infiltrated ceramic network may indicate its resistance to mechanical complications. (J Prosthet Dent 2024;132:154-164)
引用
收藏
页码:154 / 164
页数:11
相关论文
共 50 条
  • [21] Fracture Strength of Implant-Supported Ceramic Crowns with Customized Zirconia Abutments: Screw Retained vs. Cement Retained
    Lima Verde Nogueira, Lorenna Bastos
    Vilarinho Soares Moura, Carmem Dolores
    Francischone, Carlos Eduardo
    Valente, Valdimar Silva
    Mendes Alencar, Suya Moura
    Moura, Walter Leal
    Soares Martins, Gregorio Antonio
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (01): : 49 - 53
  • [22] In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures
    Koke, U
    Wolf, A
    Lenz, P
    Gilde, H
    JOURNAL OF ORAL REHABILITATION, 2004, 31 (05) : 477 - 482
  • [23] Comparison of surface roughness of additively manufactured implant-supported interim crowns fabricated with different print orientations
    Ortega, Nuria Martin
    Revilla-Leon, Marta
    Ortega, Rocio
    Gomez-Polo, Cristina
    Barmak, Abdul B.
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (02): : 141 - 148
  • [24] Cemented versus screw-retained implant-supported single-tooth crowns: a 10-year randomised controlled trial
    Vigolo, Paolo
    Mutinelli, Sabrina
    Givani, Andrea
    Stellini, Edoardo
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2012, 5 (04) : 355 - 364
  • [25] Digital analysis of fabrication accuracy and fit in additively and subtractively manufactured implant-supported fixed complete dentures
    Maldonado, Paola
    Donmez, Mustafa Borga
    Guven, Mehmet Esad
    Schimmel, Martin
    Revilla-Leon, Marta
    Cakmak, Gulce
    Yilmaz, Burak
    JOURNAL OF DENTISTRY, 2024, 150
  • [26] Resistance to Fracture in Fixed Dental Prostheses Over Cemented and Screw-Retained Implant-Supported Zirconia Cantilevers in the Anterior Region: An In Vitro Study
    Rues, Stefan
    Kappel, Stefanie
    Ruckes, Dorothee
    Rammelsberg, Peter
    Zenthoefer, Andreas
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (03) : 521 - 529
  • [27] Evaluation of debonding force of screw-retained lithium disilicate implant-supported crowns cemented to abutments of different designs and surface treatments
    Khalifa, Ahmed Abdel Latif
    Metwally, Nayrouz Adel
    Khamis, Mohamed Moataz
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01): : 215 - 220
  • [28] Cemented versus screw-retained posterior implant-supported single crowns: A 24-month randomized controlled clinical trial
    Wolfart, Stefan
    Rittich, Anne
    Gross, Karin
    Hartkamp, Oliver
    von der Stueck, Annabelle
    Raith, Stefan
    Reich, Sven
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1484 - 1495
  • [29] Straightforward tip for identifying the type of screwdriver needed for screw-retained implant-supported prostheses
    Real-Voltas, Francisco
    Figueras-Alvarez, Oscar
    Barrocal-Rodriguez, Susana
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 539 - 540
  • [30] AN ALTERNATIVE DIRECT TECHNIQUE FOR THE FABRICATION OF AN IMPLANT-SUPPORTED, SCREW-RETAINED FIXED INTERIM RESTORATION
    Yilmaz, Burak
    McGlumphy, Edwin
    Purcell, Bradley
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (02): : 137 - 139