Comparison of the Surgical Outcome between the Multiple Screw Fixation and Fixed Angle Devices for the Basicervical Femoral Neck Fractures

被引:0
|
作者
Kim, Jin-Woo [1 ]
Park, Jung-Wee [2 ]
Kim, Hyo-Jung [1 ]
Kim, Tae-Young [3 ]
Yoo, Jun-Il [4 ]
Lee, Young-Kyun [2 ]
Jang, Byung-Woong [5 ]
机构
[1] Nowon Eulji Med Ctr, Dept Orthopaed Surg, Seoul 01830, South Korea
[2] Seoul Natl Bundang Hosp, Dept Orthopaed Surg, Seongnam Si 13620, South Korea
[3] Konkuk Univ Hosp, Dept Orthopaed Surg, Seoul 05030, South Korea
[4] Inha Univ Hosp, Inha Univ, Coll Med, Dept Orthoped Surg, Incheon 22332, South Korea
[5] Soonchunhyang Univ, Seoul Hosp, Dept Orthopaed Surg, Seoul 04401, South Korea
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 05期
基金
新加坡国家研究基金会;
关键词
femoral neck fracture; multiple screw fixation; fixed angle device; surgical outcome; HIP FRACTURE; OPERATIVE MANAGEMENT; INTERNAL-FIXATION; CANNULATED SCREW; ELDERLY-PATIENTS; FEMUR; NAIL;
D O I
10.3390/medicina60050680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Provisional fixation of unstable femoral neck basicervical fractures: A web-based survey and biomechanical assessment using a sliding hip screw construct
    Alzahrani, Mohammad M.
    Culliton, Kathryn N.
    Wilkin, Geoffrey P.
    Papp, Steven R.
    Liew, Allan S.
    JOURNAL OF MUSCULOSKELETAL SURGERY AND RESEARCH, 2022, 6 (01) : 70 - 76
  • [32] Incidence and factors influencing neck shortening after screw fixation of femoral neck fractures with the femoral neck system
    Wang, Kai
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Feng, Tianxuan
    Liu, Jiajie
    Zheng, Shunze
    Liang, Yaqian
    Ouyang, Jirui
    Cui, Yubo
    Lin, Fengfei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [33] Incidence and factors influencing neck shortening after screw fixation of femoral neck fractures with the femoral neck system
    Kai Wang
    Dongze Lin
    Peisheng Chen
    Chaohui Lin
    Tianxuan Feng
    Jiajie Liu
    Shunze Zheng
    Yaqian Liang
    Jirui Ouyang
    Yubo Cui
    Fengfei Lin
    Journal of Orthopaedic Surgery and Research, 18
  • [34] FRACTURES OF FEMORAL NECK - FIXATION BY MULTIPLE THREADED WIRES
    JONES, KG
    SOUTHERN MEDICAL JOURNAL, 1966, 59 (05) : 541 - &
  • [35] Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures
    Wang, Chen
    Xu, Gui-Jun
    Han, Zhe
    Jiang, Xuan
    Zhang, Cheng-Bao
    Dong, Qiang
    Ma, Jian-Xiong
    Ma, Xin-Long
    MEDICINE, 2015, 94 (47) : e2139
  • [36] MULTIPLE PIN FIXATION OF FEMORAL-NECK FRACTURES
    MCCRAE, SC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1960, 42 (07): : 1270 - 1270
  • [37] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [38] INTRACAPSULAR FRACTURES OF THE FEMORAL-NECK - RESULTS OF CANNULATED SCREW FIXATION
    ASNIS, SE
    WANEKSGAGLIONE, L
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (12): : 1793 - 1803
  • [39] Performing Screw Fixation for Femoral Neck Fractures under Local Anaesthesia
    Chor-Yat, Chung
    Wong Sze-Hung
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2012, 16 (02) : 55 - 58
  • [40] Ideal screw positions for multiple screw fixation in femoral neck fractures - Study of proximal femur morphology in a Japanese population
    Nakanishi, Yuta
    Hiranaka, Takafumi
    Shirahama, Masahiro
    Uesugi, Masafumi
    Okimura, Kenjiro
    Tsubosaka, Masanori
    Shibata, Yousaku
    Hida, Yuuichi
    Fujishiro, Takaaki
    Uemoto, Harunobu
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (03) : 521 - 524