Comparison of the Surgical Outcome between the Multiple Screw Fixation and Fixed Angle Devices for the Basicervical Femoral Neck Fractures

被引:0
|
作者
Kim, Jin-Woo [1 ]
Park, Jung-Wee [2 ]
Kim, Hyo-Jung [1 ]
Kim, Tae-Young [3 ]
Yoo, Jun-Il [4 ]
Lee, Young-Kyun [2 ]
Jang, Byung-Woong [5 ]
机构
[1] Nowon Eulji Med Ctr, Dept Orthopaed Surg, Seoul 01830, South Korea
[2] Seoul Natl Bundang Hosp, Dept Orthopaed Surg, Seongnam Si 13620, South Korea
[3] Konkuk Univ Hosp, Dept Orthopaed Surg, Seoul 05030, South Korea
[4] Inha Univ Hosp, Inha Univ, Coll Med, Dept Orthoped Surg, Incheon 22332, South Korea
[5] Soonchunhyang Univ, Seoul Hosp, Dept Orthopaed Surg, Seoul 04401, South Korea
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 05期
基金
新加坡国家研究基金会;
关键词
femoral neck fracture; multiple screw fixation; fixed angle device; surgical outcome; HIP FRACTURE; OPERATIVE MANAGEMENT; INTERNAL-FIXATION; CANNULATED SCREW; ELDERLY-PATIENTS; FEMUR; NAIL;
D O I
10.3390/medicina60050680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Cancellous screw fixation for undisplaced femoral neck fractures in the elderly
    Manohara, Ruben
    Liang, Shen
    Huang, Deborah
    Krishna, Lingaraj
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03) : 282 - 286
  • [23] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975
  • [24] STABILITY OF FIXATION IN FEMORAL-NECK FRACTURES - COMPARISON OF 4 FIXATION DEVICES INVIVO AND IN CADAVERS
    ELMERSON, S
    ANDERSSON, GBJ
    POPE, MH
    ZETTERBERG, C
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (02): : 109 - 112
  • [25] Fixed angle device comparison in young femoral neck fractures: Dynamic hip screw vs dynamic helical hip system
    Marchand, Lucas S.
    Butler, Bennet
    McKegg, Phillip
    DeLeon, Genaro
    O'Hara, Nathan N.
    Lebrun, Christopher T.
    Sciadini, Marcus F.
    Nascone, Jason W.
    O'Toole, Robert, V
    Slobogean, Gerard M.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 590 - 595
  • [26] Angular stable multiple screw fixation (Targon FN) versus standard SHS for the fixation of femoral neck fractures
    Eschler, Anica
    Brandt, Susanne
    Gierer, Philip
    Mittlmeier, Thomas
    Gradl, Georg
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 : S76 - S80
  • [27] Testing predictors of outcome of fixed femoral neck fractures
    Weinrobe, M
    Stankewich, CJ
    Tencer, A
    Mueller, B
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (01) : A171 - A171
  • [28] Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures
    Jiang, Dajun
    Zhan, Shi
    Wang, Lei
    Shi, Lewis L.
    Ling, Ming
    Hu, Hai
    Jia, Weitao
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (08) : 1669 - 1680
  • [29] FIXATION OF DISPLACED FEMORAL-NECK FRACTURES - A COMPARISON BETWEEN SLIDING SCREW PLATE AND 4 CANCELLOUS BONE SCREWS
    MADSEN, F
    LINDE, F
    ANDERSEN, E
    BIRKE, H
    HVASS, I
    POULSEN, TD
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 212 - 216
  • [30] Results of fixed-angle device fixation (dynamic hip screw) in femoral neck fractures in young adults: a prospective study of 20 cases
    Beder, Fady Kamal
    El-Hamalawy, Ahmed Goda
    Abdel-Kader, Khaled F. M.
    Abdelmoneim, Mohamed A.
    CURRENT ORTHOPAEDIC PRACTICE, 2021, 32 (04): : 333 - 338