Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy

被引:0
|
作者
Kaiser, Klemens Paul [1 ]
Bucur, Julian [1 ]
Jandewerth, Tyll [1 ]
Kohnen, Thomas [1 ]
Lwowski, Christoph [1 ]
机构
[1] Goethe Univ, Dept Ophthalmol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
fellow eye; IOL calculation; phacovitrectomy; retinal detachment; SILICONE OIL; BIOMETRY; POWER; OPERATIONS; LENGTH;
D O I
10.1111/aos.16741
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate whether the intraocular lens (IOL) calculation of the fellow eye (FE) can be used in eyes undergoing combined phacovitrectomy.MethodsIn this retrospective, consecutive case series, we enrolled patients who underwent combined phacovitrectomy with silicone oil removal and IOL implantation at the Goethe-University. Preoperative examinations included biometry (IOLMaster 700; Carl Zeiss). We used the IOL calculation of the FE (FE group) to calculate the prediction error compared with the IOL calculation using only the axial length (AL) of the FE (AL-FE group), as well as using the AL of the operated eye (OE group) in addition to the measurable biometric parameters. IOL calculation was performed using the Barrett Universal II formula. We compared the mean (MAE) and median absolute prediction error (MedAE) with each other. Furthermore, the number of eyes with +/- 0.50, +/- 1.00 and +/- 2.00 dioptres (D) deviation from the target refraction was compared.ResultsIn total, 79 eyes of 79 patients were included. MedAE was lowest in the OE group (0.41 D), followed by FE group (1.00 D) and AL-FE group (1.02 D). Comparison between the AL-FE and FE groups showed no statistically significant difference (p = 0.712). Comparing eyes within +/- 0.50 D of the target refraction, the OE group (63.3%) performed best, followed by the AL-FE group (27.8%) and the FE group (26.6%).ConclusionOur results indicate no clinically relevant difference between using the IOL calculation of the FE versus using only the AL of the FE in addition to the measurable parameters for the IOL calculation. A two-step procedure should always be strived for.
引用
收藏
页码:e31 / e37
页数:7
相关论文
共 50 条
  • [41] Accuracy of using the axial length of the fellow eye for IOL calculation in retinal detachment eyes undergoing silicone oil removal
    Lwowski, Christoph
    Kaiser, Klemens Paul
    Bucur, Julian
    Schicho, Philipp
    Kohnen, Thomas
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (07) : 921 - 926
  • [42] Incidence and management of intraocular lens opacification after primary phacovitrectomy for combined cataract and diabetic vitrectomy
    Al-Naimy, Mohammed A.
    Khairy, Marwa A.
    Alagorie, Ahmed Roshdy
    Deiaeldin, Yasmine A.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (02) : 82 - 92
  • [43] Outcomes of preloaded toric intraocular lens implantation in eyes undergoing phacoemulsification
    Nagpal, Ritu
    Shakkarwal, Chetan
    Ahsan, Saima
    Maharana, Prafulla Kumar
    Goel, Madhav
    Sharma, Namrata
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (06) : 2480 - 2486
  • [44] Intraocular lens power calculation for silicone oil-dependent eyes
    Wang, Leyi
    Wang, Xin
    Yang, Xuepeng
    Si, Yuanyuan
    Wu, Jiayin
    Cui, Yan
    FRONTIERS IN MEDICINE, 2023, 10
  • [45] INTRAOCULAR-LENS POWER CALCULATION FOR EYES AFTER REFRACTIVE KERATOTOMY
    HOFFER, KJ
    JOURNAL OF REFRACTIVE SURGERY, 1995, 11 (06): : 490 - 493
  • [46] Predictability of intraocular lens power calculation in eyes after phototherapeutic keratectomy
    Ryo Yoneyama
    Kazutaka Kamiya
    Kei Iijima
    Masahide Takahashi
    Nobuyuki Shoji
    Japanese Journal of Ophthalmology, 2020, 64 : 62 - 67
  • [47] Intraocular lens power calculation for eyes with previous myopic LASIK - Reply
    Lin, George I. C.
    Crandall, Alan S.
    Jin, Yian
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) : 847 - 848
  • [48] Intraocular lens power calculation and optimized constants for highly myopic eyes
    Petermeier, Katrin
    Gekeler, Florian
    Messias, Andre
    Spitzer, Martin S.
    Haigis, Wolfgang
    Szurman, Peter
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09): : 1575 - 1581
  • [49] Accuracy of Intraocular Lens Power Calculation in Eyes Filled with Silicone Oil
    Kanclerz, Piotr
    Grzybowski, Andrzej
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (05) : 392 - 397
  • [50] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016