Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy

被引:0
|
作者
Kaiser, Klemens Paul [1 ]
Bucur, Julian [1 ]
Jandewerth, Tyll [1 ]
Kohnen, Thomas [1 ]
Lwowski, Christoph [1 ]
机构
[1] Goethe Univ, Dept Ophthalmol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
fellow eye; IOL calculation; phacovitrectomy; retinal detachment; SILICONE OIL; BIOMETRY; POWER; OPERATIONS; LENGTH;
D O I
10.1111/aos.16741
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate whether the intraocular lens (IOL) calculation of the fellow eye (FE) can be used in eyes undergoing combined phacovitrectomy.MethodsIn this retrospective, consecutive case series, we enrolled patients who underwent combined phacovitrectomy with silicone oil removal and IOL implantation at the Goethe-University. Preoperative examinations included biometry (IOLMaster 700; Carl Zeiss). We used the IOL calculation of the FE (FE group) to calculate the prediction error compared with the IOL calculation using only the axial length (AL) of the FE (AL-FE group), as well as using the AL of the operated eye (OE group) in addition to the measurable biometric parameters. IOL calculation was performed using the Barrett Universal II formula. We compared the mean (MAE) and median absolute prediction error (MedAE) with each other. Furthermore, the number of eyes with +/- 0.50, +/- 1.00 and +/- 2.00 dioptres (D) deviation from the target refraction was compared.ResultsIn total, 79 eyes of 79 patients were included. MedAE was lowest in the OE group (0.41 D), followed by FE group (1.00 D) and AL-FE group (1.02 D). Comparison between the AL-FE and FE groups showed no statistically significant difference (p = 0.712). Comparing eyes within +/- 0.50 D of the target refraction, the OE group (63.3%) performed best, followed by the AL-FE group (27.8%) and the FE group (26.6%).ConclusionOur results indicate no clinically relevant difference between using the IOL calculation of the FE versus using only the AL of the FE in addition to the measurable parameters for the IOL calculation. A two-step procedure should always be strived for.
引用
收藏
页码:e31 / e37
页数:7
相关论文
共 50 条
  • [31] Intraocular lens power calculation in a posterior chamber phakic intraocular lens implanted eye
    Yasa, Dilek
    Kose, Bulent
    Sucu, Mehmet Emin
    Agca, Alper
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (08) : 2017 - 2022
  • [32] Intraocular lens power calculation in a posterior chamber phakic intraocular lens implanted eye
    Dilek Yaşa
    Bülent Köse
    Mehmet Emin Sucu
    Alper Ağca
    International Ophthalmology, 2020, 40 : 2017 - 2022
  • [33] INTRAOCULAR-LENS CALCULATION - THE PROBLEM OF THE SHORT EYE
    HOFFER, KJ
    OPHTHALMIC SURGERY AND LASERS, 1981, 12 (04): : 269 - 272
  • [34] Fellow eye comparison between the ICU accommodative intraocular lens and the Acrysof MA30 monofocal intraocular lens
    Heatley, CJ
    Spalton, DJ
    Hancox, J
    Kumar, A
    Marshall, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 207 - 213
  • [35] The comparison of the intraocular lens power calculation formulas in long eyes
    Yildiz, Aydin
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (07) : 1173 - 1176
  • [36] Comparison of Intraocular Lens Power Calculation Formulae in Pediatric Eyes
    Nihalani, Bharti R.
    VanderVeen, Deborah K.
    OPHTHALMOLOGY, 2010, 117 (08) : 1493 - 1499
  • [37] Intraocular lens power calculation in eyes with short axial length
    Moschos, Marilita M.
    Chatziralli, Irini P.
    Koutsandrea, Chryssanthi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (06) : 692 - 694
  • [38] Intraocular lens power calculation errors in long eyes Reply
    Wang, Li
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (04): : 734 - 734
  • [39] Clinical Outcomes of a New Monofocal Intraocular Lens in Patients Undergoing Phacovitrectomy for Idiopathic Epiretinal Membrane
    Jukic, Tomislav
    Bajraktari, Gentian
    Vukojevic, Nenad
    Oroz, Martin
    Radolovic, Andrea
    Mandic, Kresimir
    Kalauz, Miro
    OPHTHALMOLOGICA, 2024, 247 (04) : 251 - 260
  • [40] Refractive Differences Among Intraocular Lens Formulas and Correlation With Outcomes in the Fellow Eye
    Naids, Steven Matthew
    Brown, Sarah Elise
    Tannen, Bradford L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)