Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy

被引:0
|
作者
Kaiser, Klemens Paul [1 ]
Bucur, Julian [1 ]
Jandewerth, Tyll [1 ]
Kohnen, Thomas [1 ]
Lwowski, Christoph [1 ]
机构
[1] Goethe Univ, Dept Ophthalmol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
fellow eye; IOL calculation; phacovitrectomy; retinal detachment; SILICONE OIL; BIOMETRY; POWER; OPERATIONS; LENGTH;
D O I
10.1111/aos.16741
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate whether the intraocular lens (IOL) calculation of the fellow eye (FE) can be used in eyes undergoing combined phacovitrectomy.MethodsIn this retrospective, consecutive case series, we enrolled patients who underwent combined phacovitrectomy with silicone oil removal and IOL implantation at the Goethe-University. Preoperative examinations included biometry (IOLMaster 700; Carl Zeiss). We used the IOL calculation of the FE (FE group) to calculate the prediction error compared with the IOL calculation using only the axial length (AL) of the FE (AL-FE group), as well as using the AL of the operated eye (OE group) in addition to the measurable biometric parameters. IOL calculation was performed using the Barrett Universal II formula. We compared the mean (MAE) and median absolute prediction error (MedAE) with each other. Furthermore, the number of eyes with +/- 0.50, +/- 1.00 and +/- 2.00 dioptres (D) deviation from the target refraction was compared.ResultsIn total, 79 eyes of 79 patients were included. MedAE was lowest in the OE group (0.41 D), followed by FE group (1.00 D) and AL-FE group (1.02 D). Comparison between the AL-FE and FE groups showed no statistically significant difference (p = 0.712). Comparing eyes within +/- 0.50 D of the target refraction, the OE group (63.3%) performed best, followed by the AL-FE group (27.8%) and the FE group (26.6%).ConclusionOur results indicate no clinically relevant difference between using the IOL calculation of the FE versus using only the AL of the FE in addition to the measurable parameters for the IOL calculation. A two-step procedure should always be strived for.
引用
收藏
页码:e31 / e37
页数:7
相关论文
共 50 条
  • [1] Use of Fellow Eye Data in the Calculation of Intraocular Lens Power for the Second Eye
    Olsen, Thomas
    OPHTHALMOLOGY, 2011, 118 (09) : 1710 - 1715
  • [2] Intraocular lens power calculation in phacovitrectomy patients
    Partwardhan, Ashish A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04): : 529 - 529
  • [3] Accuracy of intraocular lens formulas in combined phacovitrectomy
    Thanitcul, Chanon
    Awidi, Abdelhalim A.
    Ladas, John G.
    Siddiqui, Aazim A.
    Prescott, Christina R.
    Bower, Kraig S.
    Jun, Albert S.
    Daoud, Yassine
    Srikumaran, Divya
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [4] Accuracy of Intraocular Lens Formulas in Combined Phacovitrectomy
    Thanitcul, Chanon
    Awidi, Abdelhalim
    Daoud, Yassine Jamil
    Ladas, John G.
    Srikumaran, Divya
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [5] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208
  • [6] Accuracy of intraocular lens calculations based on fellow-eye biometry for phacovitrectomy for macula-off rhegmatogenous retinal detachments
    El-Khayat, Abdul R.
    Brent, Alex J.
    Peart, Shamfa A. M.
    Chaudhuri, Partha R.
    EYE, 2019, 33 (11) : 1756 - 1761
  • [7] Intraocular lens calculation using the ESCRS online calculator in pediatric eyes undergoing lens extraction
    Lwowski, Christoph
    Wenner, Yaroslava
    Kaiser, Klemens Paul
    Sapok, Eva
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (07): : 676 - 681
  • [8] Intraocular lens power calculation formulas accuracy in combined phacovitrectomy: an 8-formulas comparison study
    Diogo Hipólito-Fernandes
    Maria Elisa Luís
    Diogo Maleita
    Pedro Gil
    Vitor Maduro
    Lívio Costa
    Nuno Marques
    João Branco
    Nuno Alves
    International Journal of Retina and Vitreous, 7
  • [9] Accuracy of intraocular lens calculations based on fellow-eye biometry for phacovitrectomy for macula-off rhegmatogenous retinal detachments
    Abdul R. El-Khayat
    Alex J. Brent
    Shamfa A. M. Peart
    Partha R. Chaudhuri
    Eye, 2019, 33 : 1756 - 1761
  • [10] Intraocular lens power calculation formulas accuracy in combined phacovitrectomy: an 8-formulas comparison study
    Hipolito-Fernandes, Diogo
    Luis, Maria Elisa
    Maleita, Diogo
    Gil, Pedro
    Maduro, Vitor
    Costa, Livio
    Marques, Nuno
    Branco, Joao
    Alves, Nuno
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2021, 7 (01)